1. Catalogs
  2. SOCLEMA
  3. Insulated jackets SOCPROTHERM

Insulated jackets SOCPROTHERM

Insulated jackets SOCPROTHERM

Insulated jackets SOCPROTHERM

Product catalog summary
Overview
SOCPROTHERM insulated jackets are designed to provide insulation and thermal protection for sampling equipment and accessories. They address issues caused by ambient temperature changes, such as condensation, which can lead to regulator freeze-up, inaccurate sample analysis, and analyzer damage.

Key Features and Benefits
  • Prevents condensation and preserves sample integrity.
  • More economical than rigid enclosures.
  • Features an antistatic envelope loaded with carbon fiber.
  • Waterproof design.

Technical Specifications
  • Fluid maximum temperature: 120°C.
  • Maximum temperature for insulating foam: 150°C; for envelope: 200°C.
  • Envelope material: ATEX anti-static PTFE fabric.
  • Insulation material: Elastomeric foam EPDM, 13 mm thickness.
  • Temperature range: Minimum -25°C.

Dimensions and Types
  • SOCPROTHERM-TYPE-1: Sample probe jacket, 42 cm.
  • SOCPROTHERM-TYPE-2: Pipeline blanket, 43 cm x 35 cm.
  • SOCPROTHERM-TYPE-3: 30 cm extension for probe, 46 cm x 15 cm.
  • SOCPROTHERM-TYPE-4: 30 cm extension for probe, 47 cm.
  • SOCPROTHERM-TYPE-5: Valve cover extension assembly, lower part Ø 31 x h 24 cm, upper part Ø 35 x h 25 cm.
  • SOCPROTHERM-TYPE-10: Regulator cover, 27 cm x 23 cm.
  • SOCPROTHERM-TYPE-9: Cover for probe and external regulator, 47 cm x 49 cm x 34 cm.
  • SOCPROTHERM-TYPE-2-RALL: Extension straps for TYPE-2 (Ø pipe > DN700).

Configuration Examples
  • TYPE-1 + TYPE-2
  • TYPE-1 + TYPE-3 + TYPE-2
  • TYPE-9 + TYPE-4 + TYPE-2
  • TYPE-1 + TYPE-5 + TYPE-2
See more

Catalog excerpts

Insulated jackets SOCPROTHERM-1

INSULATED JACKETSSOCPROTHERM SOCPROTHERM insulated jackets are designed for insulation and thermal protection of sampling equipment and accessories. Ambient temperature changes, especially between daytime and nightime, can create numerous problems for your sampling system. Low ambient temperatures can cool a sample below its dew point, causing condensation. This condensation can result in regulator freeze up, inaccurate sample analysis and analyser damage. Insulating the pipeline and other components of the sample system will help to maintain the sample at a consistent temperature. It will help to minimise the effects of these temperature changes and prevent sample condensation. SOCPROTHERM jackets are designed to insulate the area around the sample tap, as well as sample probes, pressure regulators and valves. Caracteristics and benefits - Prevent condensation - Preserve sample integrity - More economical option than a rigid enclosure - Antistatic envelope (loaded with carbon fiber) Technical specifications Envelope material ATEX anti-static PTFE fabric Insulation material Elastomeric foam EPDM, 13 mm thickness Maximum temperature 150°C for insulating foam et 200°C for envelope Fluid maximum temperature 120°C Advanced Industrial Sampling

 Open the catalog to page 1
Insulated jackets SOCPROTHERM-2

Sample probe jacket Cover for probe and external regulator Valve cover extension assembly Lower part Ø 31 x h 24 cm Extension straps for TYPE-2 (Ø pipe > DN700) Configuration examples TYPE-1 + TYPE -2 ZA Clapeloup - 4, rue des Roses, 69280 Sainte-Consorce - France

 Open the catalog to page 2