1. Catalogs
  2. SOCLEMA
  3. Instrument temperature control heater assembly ITCH

Instrument temperature control heater assembly ITCH

Instrument temperature control heater assembly ITCH

Instrument temperature control heater assembly ITCH

Product catalog summary
Overview: The ITCH Assembly is an Instrument Temperature Control Heater Assembly designed to maintain enclosure temperature accurately across a wide range of ambient temperatures. It economically controls steam flow, eliminates the danger of overheating, and operates without external power, reducing explosion hazards.
Benefits: The assembly features an exclusive Thermoloid® thermal actuator, all stainless steel construction, compact design for fast response, corrosion resistance for long service life, and a ram-type plug for reliable shutoff. It operates within a narrow temperature band and is unaffected by variable inlet pressures, offering a wide choice of set-points.
Design Features: The thermal actuator in the TV/SC-A valve regulates steam flow based on internal enclosure temperature. The TV/HAT valves at the steam inlet and coil outlet ensure the steam supply remains hot and regulate condensate discharge temperature, respectively, for maximum economy and minimized overheating.
Operation: The ITCH Assembly provides accurate temperature control in instrument or analyzer enclosures. It is a self-contained unit offering a reliable and economical alternative to electric heating, automatically regulating steam flow to maintain desired temperatures.
Applications: The assembly is suitable for various industrial applications where precise temperature control is required.
Ordering and Specifications: The ITCH Assembly includes a steam coil, mounting bracket, TV/SC-A valve assembly, two TV/HAT valves, and weather-tight bulkhead fittings for 3/8 tubing connections. Full open temperatures range from 35°F to 200°F, with closing temperatures typically 10°F above opening temperatures. A #20 mesh strainer is recommended for all port sizes.
Parts & Materials: Key components include the TV/SC-A valve, steam coil, mounting bracket, bulkhead fitting, and TV/HAT valves, primarily constructed from 300 series stainless steel and acetal copolymer.
Dimensions & Capacities: The assembly's dimensions and capacities are detailed, with a maximum pressure of 200 PSIG (13.8 BAR) and a maximum temperature of 250°F (121°C).
See more

Catalog excerpts

Instrument temperature control heater assembly ITCH-1

INSTRUMENT TEMPERATURE CONTROL HEATER ASSEMBLY BENEFITS • Maintain enclosure temperature accurately over a wide range of ambient temperatures • Economically controls steam flow • Eliminates danger of overheating • Self-operating - no outside power or signal required, eliminating explosion hazard • Complete kit with standard tube connections for quick and easy installation • Exclusive Thermoloid® thermal actuator • All stainless steel construction • Compact, low mass - fast response • Corrosion resistant - long service life • Ram-type plug for tight reliable shutoff • Operates in narrow temperature band • Operating temperatures unaffected by variable inlet pressures • Wide choice of set-points The thermal actuator on the TV/SC-A valve senses internal enclosure temperature and regulates steam flow to the heating coil accordingly. The TV/HAT at the steam inlet keeps the steam supply hot to prevent freezing even when the TV/SC-A valve is closed. The TV/HAT at the coil outlet regulates condensate discharge temperature for maximum economy with minimized overheating potential. The ITCH Assembly comes complete with steam coil, mounting bracket, and TV/SC-A valve assembly, two TV/HAT valves, and two weather-tight bulkhead fittings for 3/8 tubing connections. TV/SC-A and TV/SC-I valves (with external connections) are also available separately. The ITCH Assembly assures accurate temperature control in an instrument or analyzer enclosure. This self-contained unit provides a reliable, economical alternative to costly, hazardous electric heating. The compact thermostatic control valve senses enclosure temperature and automatically regulates the flow of steam to the steam coil to maintain the desired temperature. ALTERNATE INSTALLATION WITH ALL CONNECTIONS INSIDE ENCLOSURE INSTRUMENT ENCLOSURE TV/SC-A VALVE STEAM COIL TV/HAT STEAM TRAP AT OUTLET STEAM TRAP

 Open the catalog to page 1
Instrument temperature control heater assembly ITCH-2

PARTS & MATERIALS MOUNTING DIMENSIONS DIMENSIONS & CAPACITIES a. Note: Closing temperature is typically 10°F above opening temperature. 2. A #20 mesh strainer is recommended for use with all port sizes. 3. Warranty information disclosed at www.thermomegatech.com/terms-conditions/ ThermOmegaTech®, Inc. 353 Ivyland Road Warminster, PA 18974 Because of continuous improvements, ThermOmegaTech® Inc. reserves the right to change the design and specifications without notic