IN-LINE TEMPERATURE CONTROL VALVE • Eliminates live steam losses • Self-operating, no power or signal required • Downstream thermal actuator for greater sensitivity • Unaffected by pressure variations • Wide choice of set-points DESIGN FEATURES • Exclusive Thermoloid® thermal actuator • Stainless steel body, fittings, spring and plug • Compact, low mass - fast response • Corrosion resistant - long service life • Ram-type plug for tight reliable shutoff • Operates in narrow temperature band TV/HAT (Tube Valve/Heat Actuated Trap) valves are ideal for use in conjunction with tracer tubing and tracing systems using pre-traced tubing bundles. TV/HAT valves replace conventional steam traps on winterization tracing, instrument tracing, condensate return system freeze protection, tracing for processes under 150°F (66°C), and other applications requiring in-line flow control based on temperature. Excessively hot samples can cause damage to expensive and sensitive hardware and electronics. For process analyzers and similar instrumentation, it is important to assure that the process samples fluids are always below the maximum allowable temperature for such instruments. Sample coolers are commonly used to reduce sample temperatures to the acceptable limits. In the event of a loss of cooling fluid to the sample cooler, or if the desired sample temperature is exceeded for any reason, the TV/HAT valve will close to prevent equipment damage. The TV/HAT valve responds only to temperature. After condensate forms and cools to near the set-point, the TV/HAT valve modulates the flow to maintain a constant condensate discharge temperature. TV/HAT valves are wide open at start-up for rapid venting and initial heat-up. TV/HAT valves are self-draining after shutdown, to eliminate freeze damage. For heating of temperature sensitive instruments or process fluids, the reduced temperature available for tracing simplifies operations and eliminates overheating problems. For other heat transfer fluids, TV/HAT valves maintain a constant discharge temperature, thus providing benefits of accurate process temperature control and improved efficiency.
Open the catalog to page 1PARTS & MATERIALS DIMENSIONS & CAPACITIES a. Note: Closing temperature is typically 10°F above opening temperature. 2. Standard fittings are Parker A-LOK. 3. Swagelok fittings replace standard Parker fittings. 4. Replace singular “X" with 0 for EPDM body seals; 1 for Viton body seals. Other seals available, consult our engineers. 5. Seal material compatibility: a. EPDM - air, water, steam, ketones, and synthetic hydraulic oils. b. Viton - air, fuel, oil, gas, petroleum-based hydraulic oils. 6. Flow direction is reversed on valves that close over 210°F (98.9°C) 7. A #20 mesh strainer is recommended....
Open the catalog to page 217 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages