The document describes the Genie® Probes™, specifically the Model 755™, which is a membrane tip probe regulator designed for sampling transmission quality natural gas. It prevents liquid carryover into the sample system, which can affect analysis and damage analyzers.

Specifications
The Model 755™ features an adjustable length and integrates a pressure regulator immediately downstream of the membrane within the pipeline. It utilizes heat from the flowing gas to prevent condensation during pressure letdown. The probe can be inserted and extracted from a pressurized line without special devices.

Applications
  • Continuous gas sampling and pressure regulation of natural gas and various refinery and petrochemical gases.
  • Gas sampling of mixtures with less than 30% hydrogen.

Benefits
  • Protects the sample system from contaminants while maintaining sample integrity.
  • Offsets temperature changes at the regulation point using flowing pipeline gas.
  • Allows easy and safe insertion and extraction from pressurized systems.
  • Complies with API, GPA, and ISO standards.

Features
  • Unique one-piece body with Genie® Membrane Technology™.
  • Adjustable length with threaded or flanged process connection.
  • Velocity tested up to 200 ft/sec.

Technical Specifications
  • Available in 3/4”, 1“, or 1.5” NPT full opening threaded or flanged valve.
  • Temperature range for Type 6 membranes: -35°F to 185°F; Type 7 membranes: up to 300°F.
  • Maximum pressure rating: NPT 3,750 psig.
  • Outlet pressure range: 0-500 psig.

Additional Information
  • Model numbering is based on specific needs, including sealing material, process connection, outlet pressure range, and probe insertion length.
  • Spare parts and accessories are available, such as sealing material replacements, membrane assembly replacements, and speed wrenches.

Contact Information
For expert product application assistance, contact A+ Corporation at 1.225.644.5255 or [email protected].
See more

Catalog excerpts

GENIE 755 sampling probe-1

Direct Drive Probe' The safest and most versatile membrane tip probe regulator available on the market Liquid carryover from the pipeline into the sample system should be prevented when sampling natural gas as it can directly impact the analysis and damage the analyzer. Genie® Probes' provide a means to insert Genie® Membrane Technology' directly into a pipeline for the purpose of separating unwanted liquid and particulate from the gas sample at flowing conditions; in compliance with industry standards. The Model 755' is an adjustable length, membrane tip probe regulator designed to sample transmission quality natural gas. The pressure regulator is built into the probe immediately downstream of the membrane, inside of the pipeline. Heat is transferred from the flowing pipeline gas to the regulator to prevent excessive Joule-Thomson cooling, helping to prevent condensation during pressure letdown. This model can be inserted and extracted from a pressurized line through a full opening valve without the use of a special insertion device. It is important to note that some applications will require additional heat to be applied before pressure regulation, and possibly multiple stages of pressure reduction. Contact us for assistance in determining heating and pressure regulation requirements. Applications • Continuous gas sampling and pressure regulation of transmission quality natural gas and various types of refinery and petrochemical gases • Gas sampling of mixtures containing less than 30% hydrogen Technical Specifications NPT: 3,750 psig (258.6 barg) Unibody flanged: Dependent upon flange ANSI classification Type 6 membranes: -35°F (-37°C)to 185°F (85°C) *Type 7 membrane: Upto 300°F (149°C) * Actual limit depends on sealing material chosen. Refer to Temperature Range Comparison Chart. Outlet: 1/4"female NPT Auxillary: 1/8"female NPT (plugged from factory) Maximum Pressure Rating Temperature Ranges Port Sizes Probe Lengths Outlet Pressure Range psig (barg) Process Connection Requirement Wetted Materials A: ~ 20", 24", 30", 36", 48", 60" (refer to L & A dimensions on back) 0-10 (0-0.7), 0-25 (0-1.7), 0-50 (0-3.4), 0-100 (0-6.9), 0-250 (0-17.2), 0-500 (0-35.4) 3/4", 1" or 1.5" NPT full opening threaded or flanged valve Ball, gate and double block and bleed valves are all suitable for use as long as their inner diameter is not less than 3/4". 1" NPT or larger process connection required for seal welding. Machined parts: 316/316L stainless steel / ISO 15156-3 compliant and Kevlar®threaded bushing All other metal parts: stainless steel / ISO 15156-3 compliant Sealing material: User defined Regulator seat material: PFA Membrane: inert Maximum Recommended Flow Rate Dependant on source pressure. See chart. Benefits • Protection of the sample system from liquid and particulate contaminants while maintaining sample integrity • Flowing pipeline gas helps to offset temperature changes at regulation point • Easy, quick, and safe insertion and extraction from pressurized systems without a special insertion device • Horizontal or vertical mounting • Velocity tested by CEESI flow lab up to 200 ft/sec • API, GPA & ISO standard compliance Features • Unique, one piece body with Genie® Membrane Technology™ • Analytically Correct™ design • Adjustable length with threaded or flanged process connection • Antifriction internal thread die • Optional speed wrench for faster installation The Sampling Experts'" | geniefiiters.com

 Open the catalog to page 1
GENIE 755 sampling probe-2

Model Numbering & Additional Part Numbers Your model number is determined by your specic needs. Choose options below. Process connection 0 = Neoprene rubber J = RGD resistant HNBR (other materials available upon request) 6 = Better Rejection; Rejects ALL types of liquids from vapor 7 = Highest Temps; Rejects ONLY high surface tension liquids (contact factory for anged options) 3 = 3/4” NPT 4 = 1” NPT 6 = 1.5” NPT Outlet pressure range (psig) Regulator outlet port Probe insertion length (L) Sealing material Membrane type How to build the model number: Spare Parts & Accessories (sold separately)...

 Open the catalog to page 2

All SOCLEMA catalogs and technical brochures

  1. JTR-H

    2  Pages

  2. JTR

    2  Pages

  3. GHR

    2  Pages

  4. TORNADO 602

    2  Pages

  5. GPHV

    2  Pages

  6. GP2

    2  Pages

  7. GPSD

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.