The DewPoint Duo™ by ZEGAZ Instruments is an advanced dewpoint measurement system capable of simultaneously measuring water and hydrocarbon dewpoints with high accuracy. It utilizes the patented CEIRS™ (Chilled-Evanescent Infrared Spectroscopy) method, which is unique to ZEGAZ products.

Key Features
  • Direct, first principle measurement with no consumables required.
  • Self-cleaning and immune to most contaminants.
  • Accurate and unambiguous results, distinguishing between hydrocarbon and water dewpoints.
  • Fully automated operation at line pressures up to 2000 psi.
  • No moving parts, carrier gas, or replacement parts needed.
  • Sensor is resistant to damage from contaminants, slugs, or aerosols.

Specifications
Performance
  • Dewpoint measurement range: 126°F (70°C) below ambient temperature.
  • Lowest detectable dewpoint: -40°F (-40°C).
  • Highest detectable dewpoint: +131°F (+55°C).
  • Measurement time: 2-12 minutes.
  • Dewpoint accuracy: ±0.9°F (±0.5°C).
  • Dewpoint repeatability: ±0.4°F (±0.2°C).
  • Dewpoint resolution: ±0.1°F (±0.1°C).

Application Conditions
  • Operating temperature: -4 to 140°F (-20 to +60°C).
  • Storage temperature: -22 to 140°F (-30 to +60°C).
  • Process pressure: Up to 2000 psi (135 bar).
  • Flow rate: 0.3-1.5 SLM.

Electrical and Communication
  • Input voltage: 100-264 VAC, DC optional.
  • Power usage: 120W peak, <30W average.
  • Signal outputs: 4x4-20mA, 3xDO, RS-232, RS-485, Ethernet.
  • Protocol: Modbus Gould RTU, Daniel RTU.

Physical
  • Size: 14”x14”x6” (355x355x150mm).
  • Weight: 40 lbs (18 kg).

Certification
  • Hazardous location: CSA Class I, Div. 1, Group B, C & D, T6.
  • Other: IP66, CE, ISO 9001 certified.
See more

Catalog excerpts

Dewpoint Duo Dewpoint analyzer-1

Water and Hydrocarbon Dewpoint Analyzer www.ZEGAZ.com ZEGAZ Instruments DewPoint Duo™ water and hydrocarbon dewpoint analyzer is the most advanced dewpoint measurement system available, capable of measuring both dewpoints simultaneously. It has an accuracy of ±0.5 °C (±0.9 0 F), distinguishes between hydrocarbon and water dewpoints and provides highly accurate, measurements. It is based on CEIRS™ (Chilled- Evanescent Infrared Spectroscopy), a patented method. ZEGAZ Instruments products are the only analyzers in the world that use CEIRS™, a spectroscopic approach that determines the dewpoint, while unambiguously determining whether it was water or hydrocarbon dewpoint. The CEIRS™ method uses advanced IR technology. It is immune to contaminations. It is designed for remote operation at line pressure up to 2000psi. It provides 4 analog outputs as well as 3 digital alarms, and serial communications. in ii ii min ii ii ii miKEY FEATURES DewPoint Duo™ has unprecedented accuracy and repeatability. The graph below shows the correlation between theoretical and DewPoint Duo™ measured values. • Direct, First Principle Measurement • NIST Tested • Self Cleaning • Immune to Most Contaminants • No Calculation or Model Errors • Distinguishes Between Hydrocarbon and Water • Fully Automated • Works at Line Pressure • Replacement Parts • Sensor Not Damaged by Contaminants, Slugs or Aerosols Comparison of CEIRS(TM) with GERG

 Open the catalog to page 1
Dewpoint Duo Dewpoint analyzer-2

DewPoint Duo™ Water and Hydrocarbon Dewpoint Analyzer www.ZEGAZ.com SPECIFICATIONS Dewpoint Measurement Range† 126⁰F (70 ⁰C) below ambient temp. † Lowest Detectable Dewpoint Highest Detectable Dewpoint +131⁰F (+55⁰C) 9 ⁰F (5⁰C) below ambient temp. Measurement Time Dewpoint Accuracy Dewpoint Repeatability Dewpoint Resolution Application Condition Operating Temperature Storage Temperature Process Pressure Flow Rate Electrical and Communication Input Voltage Power Usage Signal Outputs Modbus Gould RTU, Daniel RTU Physical Size (not including sample system) Weight (not including sample system) Certification...

 Open the catalog to page 2

All SOCLEMA catalogs and technical brochures

  1. JTR-H

    2  Pages

  2. JTR

    2  Pages

  3. GHR

    2  Pages

  4. TORNADO 602

    2  Pages

  5. GPHV

    2  Pages

  6. GP2

    2  Pages

  7. GPSD

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.