Catalog excerpts
Technical data sheet Pressure reducing valve Applications and special features • Control and maintain the downstream pressure at an adjustable reduced value, whether there is a flow or not. • Keep an outlet pressure at a constant value, even by variation of the upstream pressure (the down-stream pressure cannot vary more than 10 % of the variation of the upstream pressure, according to the Standard). • All internal component in bronze, specially adapted for sea water and aggresive water. • No maintenance required, not affected by scale or dirt. • Can be installed in any position. • Guarantee a high flow rate at a constant outlet pressure because of low head loss. • Work as pressure reducing valve (standard terminology) as well as “regulator” and as “pressure regulating valve” (when applies for gas). • Downstream setting : 1bar to 6 bar; indicative value according to EN1567 • Adjustable : supplied non adjusted. • 2 pressure gauge connections 1/4” and drain at the bottom of the casing. Technical description L1, L2, G1 and G2 correspond to liquids/gas classified into degree of danger according to the Pressure Equipment Directive (PED). The article 3.3 applies to equipments with no CE marking. Overall dimensions • Connection : female/female, BSP thread • Downstream pressure gauge connection : 1/4” • Permissible operating pressure PFA - water : See table • Maximum permissible pressure PS - other mediums : See table •θ: Mini. -10 °C Maxi. in permanent service : 80 °C (40°C domestic fuel oil) • Mediums : water, sea water, aggresive water • Approvals: ACS • International construction Standards : Pressure reducing valves EN 1567 Thread connection NF EN ISO 228
Open the catalog to page 1Technical data sheet Type 10BIS BZ - Pressure reducing valve Spare parts list and materials Anticorrosive steel Brass Brass or alu-bronze or bronze Stainless steel Stainless steel Stainless steel Bronze Alu-bronze or Messing DZR or Bronze NBR (Nitrile) Stainless steel Working principle • Pressure setting range (DN 25 - 80 mm) Inlet pressure in bars Outlet pressure in bars • Flow capacity Flow at the velocity used in the Standard (2 m/s). Maximum flow (at 0 outlet pressure) for upstream pressure of 8 bar. Kv : low in m3/h when the outlet F pressure becomes 1 bar lower than its setting at...
Open the catalog to page 2All SOCLA catalogs and technical brochures
-
SOCLA pneumatic actuator
8 Pages
-
FIX MATIC 548
1 Pages
-
VACUUM BREAKERS
1 Pages
-
filters
2 Pages
-
Butterfly valves
10 Pages
-
REGULATION
28 Pages
-
PRESSURE REDUCING VALVES
8 Pages
-
Protection
24 Pages
-
Non return
28 Pages
Archived catalogs
-
Regulation
28 Pages
-
ON/off
2 Pages
-
Non return
28 Pages
-
protection
22 Pages