Introduction
The manual provides comprehensive instructions for the QUICK 855PG Programmable SMD Rework Station, emphasizing the importance of reading and storing the manual for future reference.
Characteristics
The station includes ten programmable channels with six zones each for setting parameters such as temperature, time, and airflow. Key features include password protection, a magnetic switch handle, automatic sleeping, digital calibration, and a brushless whirlpool motor for adjustable airflow.
Usage
Designed for desoldering SMD components like SOIC, CHIP, QFP, PLCC, BGA, and tasks such as hot shrinking, drying, and preheating.
Specifications
- Power: 1300W
- Voltage Range: 200V~240V, 50HZ/60HZ
- Temperature Range: 100℃~500℃
- Airflow Range: 6~200 l/min
- Size: 250x230x150mm
- Weight: 4.45kg
Parts
Includes the main unit, handle holder, vacuum suction pen, power cord, grounding cord, and various nozzles. Optional parts like the pedal switch are available separately.
Keys and LCD Illuminate
Features keys for power, start, stop, vacuum, channel selection, data adjustment, setting, and back functions. The LCD displays current work channel, menu settings, suction pen status, pedal switch status, sleep mode, lock status, and password input status.
Operation Instructions
Instructions for handle and vacuum suction pen operation, including parameter viewing and setting, temperature, work time, and airflow adjustments.
Parameters View and Set
Users can view and set parameters for each channel, including temperature, time, and airflow, with detailed steps provided.
Sleeping
The unit automatically enters sleep mode under certain conditions, such as when the handle is placed on the holder or after a work cycle.
Menu Setting
Access requires a password. Users can set channels, lock/unlock settings, and adjust sound and pedal switch functions.
Calibration
Temperature calibration involves setting a reference temperature and adjusting based on thermometer readings.
Error Messages
Includes sensor, heater, and motor errors, with specific troubleshooting steps.
Parts Assemble and Disassemble
Instructions for assembling and disassembling nozzles and replacing the heating element, with precautions to avoid damage.
Safety Precautions
Advises on safety measures to prevent accidents, such as avoiding use in flammable environments, ensuring proper cooling, and handling the unit with care.