Group: SMC
Catalog excerpts
P1103-P1116-E.qxd 08.9.30 3:15 PM Page 1103 Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Port size Series Features Applicable tubing O.D. Screw-in for one-touch fittings Air flow Filtration (l/min(ANR)) (μm) ZA ZX ZR Page ZM ZMA ZFA ZQ b Long maintenance cycle type (Large filter surface) ZH 1/8: 50 1/8, 1/4 1/4: 200 b Adaptable for a manifold application b Metal 30 P.1105 ZU ZL ZY body ZF ZP SP ZFB Universal joint type b Unrestricted 360° piping tube mounting b With ø4, ø6 ø8, ø10 one-touch fitting b Light and compact molded resin parts ø3/16", ø1/4" ø3/8", ø1/2" ZCUK ø4: 10 ø6: 30 ø8: 50 AMJ 30 P.1108 ø10: 75 AMV AEP HEP Related Equipment ZFC In-line type b IN/OUT b With b Light straight piping ø2, ø3.2 ø4, ø6, ø8 one-touch fitting and compact molded resin parts ø1/8", ø5/13" ø5/32", ø1/4" ø5/16" ø2 : 2 ø3.2: 7 ø4 : 10 10 P.1111 ø6 : 30 ø8 : 50 1103
Open the catalog to page 1Prevents vacuum equipment The collected dust does not Large filter element surface Possible to replace element without tools Note) Do not use it in a line that is kept pressurized because it could cause the body to break. Principal Parts Material (Recommended flow rate) Thread type * L or R shows the left or right of the filter IN when viewed from front. Port size Indicate both the symbols for air suction filter and Example: In case of 6 stations of air suction Both left and right brackets.
Open the catalog to page 3Application Example Application to ejector system Supply valve/ Release valve Speed controller Suction filter_/y Vacuum pressure switch / pA_^ Application to vacuum pump system >—<£>—[^j.. i i—pf—-|->Vacuum pump Vacuum release valve/ _)(■- .Vacuum switch valve Suction filterx Vacuum pressure switch Replacement Parts Flow Characteristics Downstream side atmospheric release (pressurized) I Be sure to read before handling. I Refer to front matters 38 and 39 for Safety i Instructions and pages 844 to 846 for Vacuum 1. Be extremely careful with the piping connection screw seal to prevent...
Open the catalog to page 4Air Suction Filter Seríes ZFA Single unit Note) The above diagram is for ZFA200. The bracket location shows L side.
Open the catalog to page 5With One-touch Fittings Prevents vacuum equipment Unrestricted 360° piping tube Easily replaced filter element Piping tube can be connected or disconnected with one touch. . Note 1) Flow rate is less than 0.003 MPa of the initial pressure drop. )) Note 2) Will be manufactured upon receipt of order. Note 3) Avoid use under pressurization. f~\ Note 1) Do not use the product in an atmosphere and place where there is direct contact with L// chemicals. It may cause damage to the body. (Alcohol, acetone, etc. also cause <*~ damage, so be sure for the product not to be close to them.) Note 2) Do...
Open the catalog to page 6With One-touch Fittings Series Application Example Flow Characteristics Application to ejector system Supply valve/ Release valve Speed controller Suction filter_/y Vacuum pressure switch / pA_^ Application to vacuum pump system >—<£>—l^-}., i i—pf^-|->Vacuum pump Vacuum release valve / jf- Suction filter .Vacuum switch valve Vacuum pressure switch Release bushing One-touch fitting Universal joint;. XCIear cover Replacement Parts : O-ring is a set with spare element (l-FJFJS-A). Fluid-Air Pressure- Downstream side Temperature- Room atmospheric release temperature (pressurized) Flow rate...
Open the catalog to page 7Element Replacement_ 1. Stop the operation and reduce the internal pres- sure of the filter to atmospheric pressure. 2. Turn the transparent cover in counterclockwise direction and position the arrowhead of the collar in the transparent cover from the protruding in the "L" (LOCK) side to the protruding portion in 3. Pull the transparent cover downward to take out the element. Eliminate any dust in the transparent cover by blowing air. (Make sure there is no damage of the O-ring.) 4. Insert a new element into the body. transparent cover to the protruding portion on the "0" side, push the...
Open the catalog to page 8Air Suction Filter / In-line Type With One-touch Fittings In-line type air suction filter is used to prevent vacuum equipment trouble from occurring due to dust in the air IN/OUT straight piping Easy installation and removal with one-touch fittings Light and compact molded resin parts Cartridge type allows element replacement (Refer to page 1115 for details.) Note) Flow rate when the initial pressure drop is 3 kPa or less. Note 1 ) Do not use in atmospheres of chemicals, or where there is direct contact with it since the body may be damaged. (Alcohol, acetone, etc. may cause damage to the...
Open the catalog to page 9Application Example Fields: Semiconductor and electrical, automobile assembly, food and medical equipment, and various types of manufacturing and assembly equipment Machines: Robotic hand/material handling, automotive assembling machines, automatic transfer equipment, pick and place, printing machinery Applications: Vacuum adsorption transfer, vacuum adsorption retention, vacuum generated air flow Application to ejector system Supply valve/ Release valve Speed controller Suction filter Vacuum pressure switch / Application to vacuum pump system '>—O—í^k i i—ff—Ì->Vacuum pump Vacuum release...
Open the catalog to page 10Air Suction Filter / In-line Type With One-touch Fittings Series
Open the catalog to page 11Element Replacement Element replacement procedure 1. Stop operation and reduce the filter's internal 2. Rotate the cover counterclockwise ("O" on the cover o L marking). Refer to Figure 1. Pull the cover out of the case to remove the element. Remove dust and other debris re- maining inside the case by blowing it out with air, etc. (Also, confirm that the O-ring is not 4. Install a new element on cover and insert it into the case. Refer to Figure 2 and 3. 5. Adjust the protrusion on the cover and the slit on the case so that they match up, then push the cover into the end of the case. Next,...
Open the catalog to page 12All SMC catalogs and technical brochures
-
Serie HRR
64 Pages
-
Série VP/VG
33 Pages
-
Série XL
27 Pages
-
Série ACG/ARG/AWG
45 Pages
-
Série JXC5H/6H
36 Pages
-
LEJS100-X400 series
15 Pages
-
JMB series
13 Pages
-
JCM series
21 Pages
-
PF3A7*H
40 Pages
-
PF3W
34 Pages
-
Compact Guide Cylinder with Lock
36 Pages
-
Water Treatment
16 Pages
-
Food & Packaging Industry
4 Pages
-
Digital Gap Checker
26 Pages
-
Vacuum Pad
16 Pages
-
One-touch Fittings
224 Pages
-
Soft Start-up Valve
16 Pages
-
Electric Actuator
272 Pages
-
Rotary Actuator
40 Pages
-
Compact Guide Cylinder
18 Pages
-
Compact Slide
24 Pages
-
Air Cylinder
124 Pages
-
LEFB, LEFG-BS series
180 Pages
-
JMGP series
16 Pages
-
ISO Cylinder
32 Pages
-
IZD10
20 Pages
-
IZH10
8 Pages
-
Fan Type Lonizer
28 Pages
-
Check Valves
4 Pages
-
Compact Cylinder/Clean series
16 Pages
-
3 port solenoid Valve
74 Pages
-
Vacuum Ejector Series ZM
20 Pages
-
Series ZL
20 Pages
-
Series CM2
92 Pages
-
Series IDGA/IDG
56 Pages
-
Platform Cylinder Series CXT
14 Pages
-
IDH-A
12 Pages
-
CP96-C96-B
74 Pages
-
CVQ
24 Pages
-
HY
52 Pages
-
VNA
10 Pages
-
Series MXY
28 Pages
-
Series MXP
39 Pages
-
Air Slide Table
132 Pages
-
Compact Cylinder Series CQ2
138 Pages
-
S0700
112 Pages
-
SYJ
96 Pages
-
SY - NEW
164 Pages
-
VF
60 Pages
-
C(D)55 series
24 Pages
-
C(D)Q2 series
216 Pages
-
MGP series
36 Pages
-
11-LEFS series
19 Pages
-
LECS series
16 Pages
-
LECPA series
4 Pages
-
KQ series
80 Pages
-
IDF series
16 Pages
-
ZP series
69 Pages
-
MHF series
32 Pages
-
MHZ series
68 Pages
-
CRB series
44 Pages
-
MGJ series
7 Pages
-
AC series
98 Pages
-
VH series
14 Pages
-
LVA series
43 Pages
-
VDW series
28 Pages
-
LVM series
28 Pages
-
VX2 series
32 Pages
-
MXH series
32 Pages
-
MXF series
12 Pages
-
CXW series
48 Pages
-
CXS series
76 Pages
-
CQS series
40 Pages
-
CQM series
28 Pages
-
CLQ series
36 Pages