VX2 series - 1

Direct Operated 2 Port Solenoid Valve New RoHS Air Medium vacuum Water Oil Large flow rate Compact Lightweight Flow rate Height Weight 20 % More flow 10 ∗ (Size 1) (Size 1) ∗ Comparison with SMC convenional model Conventional model Body material ∗ % Smaller 30 ∗ % Lighter (Size 1, Aluminium body) New VX Air Enclosure Water/Oil/ Medium vacuum IP65∗ Aluminium, Resin ∗ Electrical entry "Faston" type terminal is IP40. With one-touch fittings (resin body) 68 mm 61 mm C37 (Brass), Stainless steel Power consumption 4.5 W 7W 10.5 W (Size 1) (Size 2) (Size 3) (DC) Bracket Standard equipment Series VX21/22/23 CAT.EUS70-44A-UK

Open the catalog to page 1
VX2 series - 2

Direct Operated 2 Port Solenoid Valve Medium Water vacuum Air Oil Enclosure IP65 Power consumption 4.5 W (Size 1) 7 W (Size 2) 10.5 W (Size 3) Flame resistance UL94V-0 conformed Improved armature durability Low-noise construction Metal noise reduced by the rubber damper Body material Air Aluminium, Resin Piping variations Water/ C37 (Brass), Oil/ Medium Stainless steel vacuum Thread piping, one-touch fitting Built-in full-wave rectifier type (AC specification) Improved durability Improved OFF response Service life is extended by the special construction. (compared with current shading coil)...

Open the catalog to page 2
VX2 series - 3

Series VX21/22/23 Specifications Common Specifications/Selection Steps Standard Specifications For Air For Medium Vacuum Coil specifications Note 1) Electrical entry "Faston" type terminal is IP40. Note 2) Voltage in ( ) indicates special voltage. (Refer to page 10.) Be sure to read “Specific Product Precautions” before handling. Normally Closed (N.C.) DC Specification AC Specification (Built-in Full-wave Rectifier Type) Power consumption (W) Note 1) Temperature rise (C°) Note 2) 4.5 50 7 55 10.5 65 Apparent power (VA) Note 1) 2) 7 9.5 12 Size Size 1 Size 2 Size 3 Note 1) Power consumption,...

Open the catalog to page 3
VX2 series - 4

Single Unit Model/Valve Specifications^ Passage symbol Aluminum Body Type Resin Body Type (Built-in One-touch Fittings) Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively. Refer to "Glossary of Terms" on page 16 for details on the maximum operating pressure differential. Fluid and Ambient Temperature Note) Dew point temperature: -10°C or less Valve Leakage Internal Leakage External Leakage Note) Leakage is the value at ambient temperature 20°C.

Open the catalog to page 4
VX2 series - 5

Direct Operated 2 Port Solenoid Valve How to Order (Single Unit) Single Unit Size/Valve type Body material/Port size/Orifice diameter Common Specifications Thread type Voltage/Electrical entry Electrical entry With surge \ With surge \ Conduit terminal With surge \ With surge \ Fasten terminal Other voltages and electrical options Dimensions -> Page 11 (Single unit) For other special options, refer to

Open the catalog to page 5
VX2 series - 6

Single Unit Model/Valve Specifications Passage symbol (Application example) © Used with vacuum © Used with pressure Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively. Fluid and Ambient Temperature Valve Leakage Internal Leakage Note) With no freezing External Leakage .Note) Leakage (10_6Pa-m3/sec) is the value at differential pressure

Open the catalog to page 6
VX2 series - 7

Direct Operated 2 Port Solenoid Valve Single Unit How to Order (Single Unit) Size/Valve type Body material/Port size/Orifice diameter Common Specifications •Thread type Voltage/Electrical entry Electrical entry With surge \ With surge \ Conduit terminal With surge \ With surge \ Fasten terminal Other voltages and electrical options For other special options, refer to Dimensions -> Page 11 (Single unit)

Open the catalog to page 7
VX2 series - 8

BWflETEH Single Unit Model/Valve Specifications Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively. • Refer to "Glossary of Terms" on page 16 for details on the maximum operating pressure differential. Fluid and Ambient Temperature Note) With no freezing Valve Leakage Internal Leakage External Leakage Note) Leakage is the value at ambient temperature 20°C.

Open the catalog to page 8
VX2 series - 9

Direct Operated 2 Port Solenoid Valve Single Unit How to Order (Single Unit) Size/Valve type Body material/Port size/Orifice diameter Common Specifications Thread type Voltage/Electrical entry Electrical entry With surge \ With surge \ Conduit terminal With surge \ With surge \ Fasten terminal Other voltages and electrical options Dimensions -> Page 11 (Single unit) For other special options, refer to

Open the catalog to page 9
VX2 series - 10

^ttSSEÜ Single The kinematic viscosity must not exceed 50 mm2/s. The special construction of the armature adopted in the built-in full-wave rectifier type gives an improvement in OFF response by providing clearance on the absorbed surface when it is switched ON. Model/Valve Specifications Passage symbol Note) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively. Refer to "Glossary of Terms" on page 16 for details on the maximum operating pressure differential. Fluid and Ambient Temperature Note) Kinematic viscosity: 50...

Open the catalog to page 10
VX2 series - 11

Direct Operated 2 Port Solenoid Valve Single Unit How to Order (Single Unit) Size/Valve type Body material/Port size/Orifice diameter Common Specifications Thread type Voltage/Electrical entry Electrical entry With surge \ With surge \ Conduit terminal With surge \ With surge \ Fasten terminal Other voltages and electrical options Dimensions -> Page 11 (Single unit) For other special options, refer to

Open the catalog to page 11
VX2 series - 12

Series VX21/22/23 Other Special Options Other options Electrical options VX2 1 0 A Z 1A VX2 1 0 A A Z Grommet (With surge 12 VDC voltage suppressor) 48 VAC 220 VAC 240 VAC 12 VDC 48 VAC 220 VAC 240 VAC 12 VDC 48 VAC 220 VAC 240 VAC 12 VDC 12 VDC DIN terminal Conduit terminal Conduit Faston terminal DIN terminal 1F 1G 1H 1J 1K 1L 1M 1N 1P 1Q 1R 1S 1T Symbol 1E Specification 48 VAC 220 VAC Grommet 240 VAC 12 VDC Electrical entry With light 1A 1B 1C 1D Special voltage Symbol Specification Enter standard product number. Electrical option Electrical option (Special voltage, with light) Voltage...

Open the catalog to page 12

All SMC catalogs and technical brochures

  1. Serie HRR

    64 Pages

  2. Série VP/VG

    33 Pages

  3. Série XL

    27 Pages

  4. JMB series

    13 Pages

  5. JCM series

    21 Pages

  6. PF3A7*H

    40 Pages

  7. PF3W

    34 Pages

  8. Vacuum Pad

    16 Pages

  9. Compact Slide

    24 Pages

  10. Air Cylinder

    124 Pages

  11. JMGP series

    16 Pages

  12. ISO Cylinder

    32 Pages

  13. IZD10

    20 Pages

  14. IZH10

    8 Pages

  15. Check Valves

    4 Pages

  16. Series ZL

    20 Pages

  17. Series CM2

    92 Pages

  18. IDH-A

    12 Pages

  19. CP96-C96-B

    74 Pages

  20. CVQ

    24 Pages

  21. HY

    52 Pages

  22. VNA

    10 Pages

  23. Series MXY

    28 Pages

  24. Series MXP

    39 Pages

  25. Air Slide Table

    132 Pages

  26. S0700

    112 Pages

  27. SYJ

    96 Pages

  28. SY - NEW

    164 Pages

  29. VF

    60 Pages

  30. C(D)55 series

    24 Pages

  31. C(D)Q2 series

    216 Pages

  32. MGP series

    36 Pages

  33. 11-LEFS series

    19 Pages

  34. LECS series

    16 Pages

  35. LECPA series

    4 Pages

  36. KQ series

    80 Pages

  37. IDF series

    16 Pages

  38. ZP series

    69 Pages

  39. MHF series

    32 Pages

  40. MHZ series

    68 Pages

  41. CRB series

    44 Pages

  42. MGJ series

    7 Pages

  43. AC series

    98 Pages

  44. VH series

    14 Pages

  45. LVA series

    43 Pages

  46. VDW series

    28 Pages

  47. LVM series

    28 Pages

  48. MXH series

    32 Pages

  49. MXF series

    12 Pages

  50. CXW series

    48 Pages

  51. CXS series

    76 Pages

  52. CQS series

    40 Pages

  53. CQM series

    28 Pages

  54. CLQ series

    36 Pages

Archived catalogs

  1. KR

    7 Pages

  2. KF

    16 Pages

  3. AFF

    80 Pages

  4. HAA

    3 Pages

  5. ZFA

    14 Pages

  6. ZA

    13 Pages

  7. D

    117 Pages

  8. RB

    23 Pages

  9. cep

    44 Pages

  10. rsq

    30 Pages

  11. CLK

    51 Pages

  12. MK

    20 Pages

  13. CLJ

    65 Pages

  14. ARG

    48 Pages

  15. VXA

    17 Pages

  16. MXU

    12 Pages