Group: SMC
Catalog excerpts
Built-in suction filter and silencer • Air supply valve for generating a vacuum • Vacuum release valve (equipped with a flow volume adjustment valve) • Vacuum pressure switch (solid state or iaphragm style) Adaptable for manifold application All tubing, wiring, indicators, and adjustment functions have been eliminated from the side surfaces, thus enabling assembly and maintenance while linked to a manifold. Maximum air suction volume Maximum vacuum pressure Two-stage nozzle construction The suction volume has been increased by 40% through the adoption of a two-stage nozzle 15.5mm width, 400g (full system) Increased suction volume through Nozzle diHuser performance/Second stage Nozzle difluser performance Suction flow rate application electrical, automobile medical equipment, assembly equipment Machine Robotics for material types handling, automatic assembly equipment, automatic transport equipment, pick-and-place, Functions Vacuum picking and transport, vacuum
Open the catalog to page 1Vacuum Ejector With Valve and Switch Release valve Without valve With valve Without valve Single/manifold For single For manifold, Common SUP For manifold, Individual SUP For single For manifold, Common SUP For manifold, Individual SUP Standard High noise reduction ∗Silencer is applicable to single unit style. Side/Bottom entry Side entry 1 point setting/without analog output/200 degrees setting 2 point setting/without analog output/3 rotation setting 2 point setting/without analog output /200 degrees setting 1 point setting/analog output/3 rotation setting 1 point setting/analog output/200...
Open the catalog to page 2Vacuum Ejector/Series Table q How to Order Connector for Solid State Switch • Without lead wire (A connector and 4 sockets) • With lead wire Note) If ordering a switch with 5m lead wire, indicate the switch without connector and lead wire with connector. Ex.) ZM -E15CN····················1 pc. ZS-20-5A-50 ································ 1 pc. Table w How to Order Connector for Supply Valve and Vacuum Release Valve (DC) Note) If ordering a valve with 600mm or longer lead wire, indicate the valve without connector and connector ass'y. 〈Ex.〉 Lead wire length: 1000mm ZM -K1LO············1 pc....
Open the catalog to page 3Built-in suction filter and silencer Air supply valve for generating a vacuum Vacuum release valve (equipped with a flow volume adjustment valve) Vacuum pressure switch (solid state, diaphragm) Adaptable for a manifold application All tubing, wiring, indicators, and adjustment functions have been eliminated from the side surface, thus enabling assembly and maintenance while linked in a manifold. EXH system common SUP system common, individual Maximum air suction volume increased by 40% Maximum vacuum pressure – 84kPa The suction volume has been increased by 40% through the adoption of a...
Open the catalog to page 4Vacuum Ejector/Series Precautions Be sure to read before handling. Refer to p.0-20 and 021 for Safety Instructions and common precautions on the products mentioned in this catalogue, and refer to p.3.0-2 for precautions on every series. Description Body Valve cover Adapter plate Cover Tension bolt Release flow adjusting needle Material Aluminum die cast Zinc die cast Zinc die cast Zinc die cast Stainless steel/Polyacetal Brass Without switch: ZM-HCA, With switch: ZM-HCB Electroless nickel plated Description Filter cover ass'y Diffuser ass'y Suction filter Silencer ass'y Pilot valve Poppet...
Open the catalog to page 5Exhaust Characteristics/Flow Characteristics Standard supply pressure: H—0.5MPa Exhaust characteristics Flow characteristics Debit Wmin) Exhaust characteristics
Open the catalog to page 6Exhaust Characteristics/Flow Characteristics standard supply pressure: M-o.35MPa Suction flow rate Flow characteristics are expressed in ejector vacuum pressure and suction flow. Fluctuations in the suction flow rate will change the vacuum pressure. Normally this relationship is expressed in ejector standard use. In graph, Pmax is according to catalogue use. Changes in vacuum pressure are expressed in the order below. 1) When ejector suction port is covered and made airtight, suction flow is 0 and vacuum pressure is at maximum value (Pmax). 2) When suction port is opened gradually, air can...
Open the catalog to page 7Vacuum Pressure Switch/Solid State Switch (ZSE). Diaphragm Switch (ZSM) Vacuum Switch Specifications *When using ejector system, instantaneous pressure up to 0.5MPa will not damage the switch. Solid State Switch (ZSE)_ Brown lead wire: connect to power supply terminal (+) to operate the switch main circuit Black lead wire: connect to load (PLC input or relay) In case of connector type, do not connect the green lead wire. Brown lead wire: connect to power supply terminal (+) to operate the switch main circuit. Black lead wire: connect to the load (PLC input or relay) Gray lead wire: connect...
Open the catalog to page 8Hysteresis is the difference in pressure when the output signal is ON and OFF. The pressure Set the pressure adjustment screw to be within 18 turns from its minimum setting. A hole is provided in one side of the window of the silencer's exhaust port. Therefore, if the silencer is to be attached against a wall or a board, make sure that the window of the exhaust port is not covered by the wall or the To reverse the position, apply your finger to the side without a hole to forcefully push and remove the silencer. Then, turn the silencer around and push it into place. At this time, make sure...
Open the catalog to page 9Single/Without Valve Basic Style Silencer assembly Dimensions of model with high noise reduction (Side entry style is equipped with plugs.) Single/Without Valve With Vacuum Switch Silencer assembly_ Dimensions of model with high noise reduction (Side entry style is equipped with plugs.)
Open the catalog to page 10All SMC catalogs and technical brochures
-
Serie HRR
64 Pages
-
Série VP/VG
33 Pages
-
Série XL
27 Pages
-
Série ACG/ARG/AWG
45 Pages
-
Série JXC5H/6H
36 Pages
-
LEJS100-X400 series
15 Pages
-
JMB series
13 Pages
-
JCM series
21 Pages
-
PF3A7*H
40 Pages
-
PF3W
34 Pages
-
Compact Guide Cylinder with Lock
36 Pages
-
Water Treatment
16 Pages
-
Food & Packaging Industry
4 Pages
-
Digital Gap Checker
26 Pages
-
Vacuum Pad
16 Pages
-
One-touch Fittings
224 Pages
-
Soft Start-up Valve
16 Pages
-
Electric Actuator
272 Pages
-
Rotary Actuator
40 Pages
-
Compact Guide Cylinder
18 Pages
-
Compact Slide
24 Pages
-
Air Cylinder
124 Pages
-
LEFB, LEFG-BS series
180 Pages
-
JMGP series
16 Pages
-
ISO Cylinder
32 Pages
-
IZD10
20 Pages
-
IZH10
8 Pages
-
Fan Type Lonizer
28 Pages
-
Check Valves
4 Pages
-
Compact Cylinder/Clean series
16 Pages
-
3 port solenoid Valve
74 Pages
-
Series ZL
20 Pages
-
Series CM2
92 Pages
-
Series IDGA/IDG
56 Pages
-
Platform Cylinder Series CXT
14 Pages
-
IDH-A
12 Pages
-
CP96-C96-B
74 Pages
-
CVQ
24 Pages
-
HY
52 Pages
-
VNA
10 Pages
-
Series MXY
28 Pages
-
Series MXP
39 Pages
-
Air Slide Table
132 Pages
-
Compact Cylinder Series CQ2
138 Pages
-
S0700
112 Pages
-
SYJ
96 Pages
-
SY - NEW
164 Pages
-
VF
60 Pages
-
C(D)55 series
24 Pages
-
C(D)Q2 series
216 Pages
-
MGP series
36 Pages
-
11-LEFS series
19 Pages
-
LECS series
16 Pages
-
LECPA series
4 Pages
-
KQ series
80 Pages
-
IDF series
16 Pages
-
ZP series
69 Pages
-
MHF series
32 Pages
-
MHZ series
68 Pages
-
CRB series
44 Pages
-
MGJ series
7 Pages
-
AC series
98 Pages
-
VH series
14 Pages
-
LVA series
43 Pages
-
VDW series
28 Pages
-
LVM series
28 Pages
-
VX2 series
32 Pages
-
MXH series
32 Pages
-
MXF series
12 Pages
-
CXW series
48 Pages
-
CXS series
76 Pages
-
CQS series
40 Pages
-
CQM series
28 Pages
-
CLQ series
36 Pages