Series IDGA/IDG-1

Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point (–60°C) No vibration or heat discharge Purge air flow rate [L/min [ANR]] Energy saving R Reduced in purge air flow by up to Existing model Purge air flow rate (rated conditions) Reduced purge Purge air flow rate Purge ratio [L/min [ANR]] [%] Running cost [€/year] [Calculation conditions] Air unit price: 0.02 €/m3 Operating hours: 12 hours/day Annual operating days: 250 days/year Variations Unit Type Single Unit Type Reduced purge IDG२A Series IDG२A Purge air flow reduction type A white body is introduced. Mist separator Micro mist separator Micro mist separator Tube configuration low flow rate type When dry clean air and pressure control are required. Mist separator When dry clean air is required. Single Unit Body size Standard dew point

 Open the catalog to page 1
Series IDGA/IDG-2

T Space Total length is shortened. saving Max. 59 mm M T High Time to reach the rated dew point performance Shortened by 40 minutes S Reduced purge IDG२A Series Under SMC test condition Time to reach the rated dew point (minutes) Existing model ∗ Standard dew point: –40°C/L, –60°C/H Reduced purge Existing model Existing model Dew point indicator visually confirms air drying. (Except IDG1) (Optional on IDG3, IDG5, IDG3H, IDG5H) Colour of the dew point indicator ¼ Normal operating: Blue ¼ Initial state: White/Pink Fitting for exhausting purge air for dew point indicator Model with fitting for purge...

 Open the catalog to page 2
Series IDGA/IDG-3

Series IDGU A/IDG Dehumidification Principle The membrane air dryer uses hollow fibers composed of a macro molecular membrane through which moisture passes easily, but is difficult for air (oxygen and nitrogen) to pass through. When humid, compressed air is supplied to the inside of the hollow fibers, only moisture permeates the membrane and moves to the outside between the moisture inside and outside of the fibers. The compressed of the dryer. Part of the dry air from the outlet side is passed through a very small orifice to reduce the pressure and purge the outside of the hollow fibers. The...

 Open the catalog to page 3
Series IDGA/IDG-4

Series Variations Meets a wide variety of flow rates (10 to 1000 L/min [ANR]) and dew points (Atmospheric pressure dew point: –15°C to –60°C). Single Unit Type Standard dew point: –20°C Standard dew point: –15°C Standard dew point: –40°C Standard dew point: –60°C Series Outlet air flow rate [L/min [ANR]] Outlet air flow rate [L/min [ANR]] Outlet air flow rate [L/min [ANR]] Outlet air flow rate [L/min [ANR]] Note) Standard dew point: Outlet air atmospheric pressure dew point under standard performance conditions Outlet air flow rate: Values under standard performance conditions

 Open the catalog to page 4
Series IDGA/IDG-5

Series IDG २A/IDG Unit Type A mist separator, micro mist separator, or micro mist separator with pre-filter combined with a single unit Standard dew point: – 20°C Standard dew point: –15°C Standard dew point: – 40°C Standard dew point: – 60°C Series Outlet air flow rate [L/min [ANR]] Outlet air flow rate [L/min [ANR]] Outlet air flow rate [L/min [ANR]] Outlet air flow rate [L/min [ANR]] ∗ Rated conditions are 0.7 MPa of inlet air pressure and 25°C of inlet air temperature. A regulator combined with the type M Standard dew point: – 20°C Standard dew point: –15°C Standard dew point: – 40°C Standard...

 Open the catalog to page 5
Series IDGA/IDG-6

Membrane Air Dryer/Single Unit Type Reduced purge IDG२A Series Standard dew point −20°C, −15°C, −40°C, −60°C How to Order Reduced purge IDG२A Series Standard dew point temperature and air flow rate Flow direction (Right → Left) With fitting for purge air discharge Note) In the case of two or more options, indicate them alphabetically. Thread type Symbol None (Standard) None (Standard) Standard Flow rate by size Outlet air flow rate [L/min [ANR]] Symbol dew point 30 50 60 75 100 [°C] −20 300 500 — Select from Series IDG −15 300 500 H With bracket Note) When symbol B is indicated, a bracket assembly...

 Open the catalog to page 6
Series IDGA/IDG-7

Membrane Air Dryer/Single Unit Type Single Unit Type None (Standard) Standard dew point temperature and air flow rate Model Selection Accessory Symbol With bracket (Except IDG1) Note) When symbol B is indicated, a bracket assembly with a part number shown in the table left below is included as an accessory. Select from Series IDG२A Unit Type Port size Port size Thread type Bracket Assembly (Accessory) Part No. Part no. b Flow direction (Right → Left) — With dew point indicator — None (Standard) With fitting for purge air discharge Specific Product Precautions Standard equipment Note) In the case...

 Open the catalog to page 7
Series IDGA/IDG-8

Reduced purge IDG२A Series Standard Specifications/Single Unit Type (Standard dew point −20°C, −15°C) Standard dew point…−20°C IDG1 Standard performance conditions Range of operating conditions Model Fluid Inlet air pressure [MPa] Inlet air temperature [°C] Note 1) Ambient temperature [°C] Note 1) Standard Outlet air atmospheric perfor- pressure dew point [°C] mance Inlet air flow rate [L/min [ANR]] Note 2) Outlet air flow rate [L/min [ANR]] Purge air flow rate [L/min [ANR]] Note 3) Inlet air pressure [MPa] Inlet air temperature [°C] Inlet air saturation temperature [°C] Ambient temperature [°C]...

 Open the catalog to page 8
Series IDGA/IDG-9

Membrane Air Dryer/Single Unit Type Reduced purge IDG२A Series Standard Specifications/Single Unit Type (Standard dew point −40°C, −60°C) Standard performance conditions Range of operating conditions Model IDG30LA IDG50LA IDG60LA IDG75LA IDG100LA Compressed air Fluid 0.3 to 1.0 Inlet air pressure [MPa] −5 to 50 Inlet air temperature [°C] Note 1) −5 to 50 Ambient temperature [°C] Note 1) Standard Outlet air atmospheric perfor- pressure dew point [°C] −40 mance Note 2) 400 93 135 224 308 Inlet air flow rate [L/min [ANR]] 300 75 110 170 240 Outlet air flow rate [L/min [ANR]] 100 18 25 54 68 Purge...

 Open the catalog to page 9

All SMC catalogs and technical brochures

  1. Serie HRR

    64  Pages

  2. Série VP/VG

    33  Pages

  3. Série XL

    27  Pages

  4. Série JXC5H/6H

    36  Pages

  5. JMB series

    13  Pages

  6. JCM series

    21  Pages

  7. PF3A7*H

    40  Pages

  8. PF3W

    34  Pages

  9. Water Treatment

    16  Pages

  10. Vacuum Pad

    16  Pages

  11. Rotary Actuator

    40  Pages

  12. Compact Slide

    24  Pages

  13. Air Cylinder

    124  Pages

  14. JMGP series

    16  Pages

  15. ISO Cylinder

    32  Pages

  16. IZD10

    20  Pages

  17. IZH10

    8  Pages

  18. Check Valves

    4  Pages

  19. Series ZL

    20  Pages

  20. Series CM2

    92  Pages

  21. IDH-A

    12  Pages

  22. CP96-C96-B

    74  Pages

  23. CVQ

    24  Pages

  24. HY

    52  Pages

  25. VNA

    10  Pages

  26. Series MXY

    28  Pages

  27. Series MXP

    39  Pages

  28. Air Slide Table

    132  Pages

  29. S0700

    112  Pages

  30. SYJ

    96  Pages

  31. SY - NEW

    164  Pages

  32. VF

    60  Pages

  33. C(D)55 series

    24  Pages

  34. C(D)Q2 series

    216  Pages

  35. MGP series

    36  Pages

  36. 11-LEFS series

    19  Pages

  37. LECS series

    16  Pages

  38. LECPA series

    4  Pages

  39. KQ series

    80  Pages

  40. IDF series

    16  Pages

  41. ZP series

    69  Pages

  42. MHF series

    32  Pages

  43. MHZ series

    68  Pages

  44. CRB series

    44  Pages

  45. MGJ series

    7  Pages

  46. AC series

    98  Pages

  47. VH series

    14  Pages

  48. LVA series

    43  Pages

  49. VDW series

    28  Pages

  50. LVM series

    28  Pages

  51. VX2 series

    32  Pages

  52. MXH series

    32  Pages

  53. MXF series

    12  Pages

  54. CXW series

    48  Pages

  55. CXS series

    76  Pages

  56. CQS series

    40  Pages

  57. CQM series

    28  Pages

  58. CLQ series

    36  Pages

Archived catalogs

  1. KR

    7  Pages

  2. KF

    16  Pages

  3. AFF

    80  Pages

  4. HAA

    3  Pages

  5. ZFA

    14  Pages

  6. ZA

    13  Pages

  7. D

    117  Pages

  8. RB

    23  Pages

  9. cep

    44  Pages

  10. rsq

    30  Pages

  11. CLK

    51  Pages

  12. MK

    20  Pages

  13. CLJ

    65  Pages

  14. ARG

    48  Pages

  15. VXA

    17  Pages

  16. MXU

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.