Serie HRR-1

Circulating Fluid Temperature Controller Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration (UL Standards) ∗ Refer to page 5 for applicable models. An inverter pump mounted option (Option symbol “T1”) has been added for the HRR012 to 030 (200 V). Operable without the need to remove the unit from the rack Front access Space saving Simple to control, service, and maintain with all filters and drainage accessible via the front panel Multiple chillers can be mounted to a 19-inch rack. ∗1 Refer to page 1 for details on 19-inch racks. Drain port DI filter (Option) (Op ption) Bypass valve (Standard) Cooling capacity Particle filter (Standard) Temperature stability Global power supply Monitoring Software Can conduct all setting operations as well as monitor the operating status ¡USB 2.0 type B ¡Compatible OS: Windows 7/10 (.NET Framework 3.5 or higher) ∗ A dedicated driver is required to use with Windows 7. ¡Supported languages: English, German, Japanese, French, Italian, Russian, Spanish, Turkish, Chinese, Korean

 Open the catalog to page 1
Serie HRR-2

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Front access Maintenance DI filter replacement Drain pan (Built-in water leakage sensor) Optional Accessories The leakage sensor detects fluid leakage. The drain pan prevents leaked fluid from pooling at the bottom of the product. Water leakage sensor ∗ Not included for Option Z Discharge of the circulating fluid Drain port (Rc1/4) Handle (Accessory) ∗ Not included for Option Z and the HRR010 Replacement particle filter element Optional Accessories Cleaning of the dustproof filter Space saving Footprint can be reduced...

 Open the catalog to page 2
Serie HRR-3

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Setting and Adjustment A bypass valve and flow sensor are yp built in (standard). Flow rate and pressure adjustment can be seen on the displayed panel. ∗ Option Z does not come with a bypass valve or flow sensor. ∗ Option Z1 does not come with a flow sensor. Open Close Colour LCD screen Current value (displayed in white): Discharge temperature, pressure, flow rate, etc. Angled inlet allows for the easy supply of circulating fluid Easy to check circulating fluid level Set value (displayed in green): Set temperature,...

 Open the catalog to page 3
Serie HRR-4

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Temperature stability: ± 0.1 °C A precision temperature control method which utilises expansion valves and temperature sensors allowed for the realisation of a product with a high temperature stability of ± 0.1 °C. Air-cooled Refrigeration Circulating fluid circuit Refrigeration circuit ∗1 Not included for Options Z and Z1 ∗2 Not included for Option Z Temperature sensor Temperature Pressure sensor sensor (For discharge) Solenoid valve for DI control Bypass Facility water circuit Electric conductivity circuit (For...

 Open the catalog to page 4
Serie HRR-5

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Self-diagnosis function and alarm code display Display of 28 types of alarm codes (For details a p. 29 ) Operation is monitored at all times by the integrated sensor. The applicable alarm code (28 types) is displayed after self-diagnosis. Ex.) AL02 “Low level in tank” Changeable alarm set values Setting item Circulating fluid discharge temperature rise Alarm code Circulating fluid discharge temperature drop Circulating fluid discharge pressure rise Circulating fluid flow rate reduction Lights up LOW a LEVEL a WRN...

 Open the catalog to page 5
Serie HRR-6

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Communication functions Serial communication (RS-232C/RS-485) and contact input/output signals (2 inputs and 3 outputs) are equipped as standard. This allows for communication with the user’s equipment and system construction, depending on the application. Ex. 1 Remote signal I/O through serial communication Ex. 2 Remote operation signal input Remote operation is enabled (to start and stop operation) through serial communication. The chiller can be operated remotely by contact input signals. ¡Circulating fluid...

 Open the catalog to page 6
Serie HRR-7

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Inverter specification mechanical sealless pump HRR010 to 030 Option T1, HRR050-२-40 ¡As the pump has no external leakage of the circulating fluid, a periodic leakage check and replacement of the mechanical seal are not necessary. ¡Circulating fluid pressure adjustable (Pressure adjustment via bypass piping is not required.) ¡There is no pump capacity difference between the 50 Hz and the 60 Hz. Power supply (24 VDC) available Power can be supplied from the contact input/output communication connector to external...

 Open the catalog to page 7
Serie HRR-8

Thermo-chiller/Rack Mount Type Air-cooled Refrigeration Water-cooled Refrigeration Global Supply Network SMC has a comprehensive network in the global market. We now have a presence of more than 560 branch offices and distributors in 83 countries and regions worldwide. With this global network, we are able to provide a global supply of our substantial range of products and high-quality customer service. We also provide full support to local factories, foreign manufacturing companies, and Japanese companies in each country. Circulating Fluid/Facility Water Line Equipment For details, refer to the...

 Open the catalog to page 8
Serie HRR-9

Thermo-chiller/Rack Mount Type HRR Series HRR010 How to Order Air-cooled Refrigeration (Single-phase 100/115 VAC) ············ p. 8-1 Water-cooled Refrigeration (Single-phase 100/115 VAC) ············ p. 8-1 Air-cooled Refrigeration (Single-phase 200 to 230 VAC) ··············· p. 9 Water-cooled Refrigeration (Single-phase 200 to 230 VAC) ··············· p. 9 Specifications Air-cooled Refrigeration (Single-phase 100/115 VAC) ············ p. 8-2 Water-cooled Refrigeration (Single-phase 100/115 VAC) ············ p. 8-3 Air-cooled Refrigeration (Single-phase 200 to 230 VAC) ············· p. 10 Water-cooled...

 Open the catalog to page 9

All SMC catalogs and technical brochures

  1. Série VP/VG

    33  Pages

  2. Série XL

    27  Pages

  3. Série JXC5H/6H

    36  Pages

  4. JMB series

    13  Pages

  5. JCM series

    21  Pages

  6. PF3A7*H

    40  Pages

  7. PF3W

    34  Pages

  8. Water Treatment

    16  Pages

  9. Vacuum Pad

    16  Pages

  10. Rotary Actuator

    40  Pages

  11. Compact Slide

    24  Pages

  12. Air Cylinder

    124  Pages

  13. JMGP series

    16  Pages

  14. ISO Cylinder

    32  Pages

  15. IZD10

    20  Pages

  16. IZH10

    8  Pages

  17. Check Valves

    4  Pages

  18. Series ZL

    20  Pages

  19. Series CM2

    92  Pages

  20. Series IDGA/IDG

    56  Pages

  21. IDH-A

    12  Pages

  22. CP96-C96-B

    74  Pages

  23. CVQ

    24  Pages

  24. HY

    52  Pages

  25. VNA

    10  Pages

  26. Series MXY

    28  Pages

  27. Series MXP

    39  Pages

  28. Air Slide Table

    132  Pages

  29. S0700

    112  Pages

  30. SYJ

    96  Pages

  31. SY - NEW

    164  Pages

  32. VF

    60  Pages

  33. C(D)55 series

    24  Pages

  34. C(D)Q2 series

    216  Pages

  35. MGP series

    36  Pages

  36. 11-LEFS series

    19  Pages

  37. LECS series

    16  Pages

  38. LECPA series

    4  Pages

  39. KQ series

    80  Pages

  40. IDF series

    16  Pages

  41. ZP series

    69  Pages

  42. MHF series

    32  Pages

  43. MHZ series

    68  Pages

  44. CRB series

    44  Pages

  45. MGJ series

    7  Pages

  46. AC series

    98  Pages

  47. VH series

    14  Pages

  48. LVA series

    43  Pages

  49. VDW series

    28  Pages

  50. LVM series

    28  Pages

  51. VX2 series

    32  Pages

  52. MXH series

    32  Pages

  53. MXF series

    12  Pages

  54. CXW series

    48  Pages

  55. CXS series

    76  Pages

  56. CQS series

    40  Pages

  57. CQM series

    28  Pages

  58. CLQ series

    36  Pages

Archived catalogs

  1. KR

    7  Pages

  2. KF

    16  Pages

  3. AFF

    80  Pages

  4. HAA

    3  Pages

  5. ZFA

    14  Pages

  6. ZA

    13  Pages

  7. D

    117  Pages

  8. RB

    23  Pages

  9. cep

    44  Pages

  10. rsq

    30  Pages

  11. CLK

    51  Pages

  12. MK

    20  Pages

  13. CLJ

    65  Pages

  14. ARG

    48  Pages

  15. VXA

    17  Pages

  16. MXU

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.