Group: SMC
Catalog excerpts
Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature: Max. 45 °C Inlet air temperature: Max. 65 °C 810 m3/h (23 % increase compared to the existing model) Power supply voltage Single-phase 230 VAC (50 Hz) New An option with cool compressed air output has been added. An option with Chinese labels and a Chinese operation manual has been added. A bypass piping set has been added as an optional accessory.
Open the catalog to page 1Refrigerated Air Dryer IDFA Series Applicable for the hightemperature environments Increased air flow capacity IDFA60 Existing model Ambient temperature IDFA Series IDFA Series New stainless steel heat exchanger helps reduce the load of the compressor The temperature range for normal operating conditions is indicated by the green zone. Evaporation thermometer Dustproof filter provided as a standard accessory Prevents clogging of the condenser Can be installed without tools All electrical components are located in the front of the product. The electrical components can be checked by removing...
Open the catalog to page 2Refrigerated Air Dryer IDFA Series Series Variations Rated inlet condition Air flow capacity [m3/h] Rated ambient temperature Dew point 3 °C Dew point 7 °C Dew point 10 °C Port size Cool compressed air output · Anti-corrosive treatment for copper tube New With Chinese labels and a Chinese operation manual · With a heavy-duty auto drain · With an earth leakage breaker · With a terminal block for operating, error, and remote operation signals · With a timer controlled solenoid valve type auto drain Optional accessories · Foundation bolt set · Piping adapter New Bypass piping set Auto Drain...
Open the catalog to page 3Refrigerated Air Dryer IDFA Series Protect Pneumatic Equipment from Moisture! An air dryer removes the vapour from the moist compressed air delivered by the compressor and prevents it from causing the pneumatic equipment to fail. ¡Malfunctioning of valves and actuators caused by dripping grease Effects of moisture on equipment ¡Generation of water droplets ¡Decomposition of auto drain caused by rusting inside pipes oom Micro mist or r ss separator Main line filter Mist separator Control panel The malfunction of air bearings of 3D measurement device, etc. Washing machine
Open the catalog to page 4IDFA Series Model Selection Air dryers should be selected based on the corrected air flow capacity while taking operating environment and facility into account. Select the air dryer model in accordance with the following procedure. IDFA Selection Example A Ambient temperature Condition Inlet air temperature 40 °C Read the correction factors. Read the correction factors A to C suitable to the operating conditions. Air flow rate Outlet air pressure dew point Data symbol ∗1 Values obtained from the table below Calculate the corrected air flow capacity. Obtain the corrected air flow capacity from...
Open the catalog to page 5IDFA60/70/80/90 Series (Max. inlet air temperature: 65 °C, Max. ambient temperature: 45 °C) Description None Cool compressed air output Anti-corrosive treatment for copper tube With Chinese labels and a Chinese operation manual With a heavy-duty auto drain (The maximum operating pressure is 1.6 MPa.) With an earth leakage breaker With a terminal block for operating, error, and remote operation signals With a timer controlled solenoid valve type auto drain (The maximum operating pressure is 1.6 MPa.) ∗ When multiple options are combined, indicate symbols in alphabetical order. ∗ The...
Open the catalog to page 6IDFA Series Standard Specifications Model Specifications Fluid Inlet air temperature [°C] Inlet air pressure [MPa] Ambient temperature (Humidity) [°C] Outlet air pressure 3 °C Standard dew point Outlet air pressure condition 7 °C dew point (ANR)∗2 Air Outlet air pressure 10 °C flow dew point Outlet air pressure capacity 3 °C dew point [m3/h] Compressor Outlet air pressure intake 7 °C dew point condition∗3 Outlet air pressure 10 °C dew point Inlet air pressure [MPa] Inlet air temperature [°C] Ambient temperature [°C] Power supply voltage (Frequency) Electric spec. Maximum air flow capacity Power...
Open the catalog to page 7IDFA Series Construction (Air/Refrigerant Circuit) Humid, hot air coming into the air dryer will be cooled down by a cooler re-heater (heat exchanger). Water condensed at this time will be removed from the air by an auto drain and drained out automatically. Air separated from the water will be heated by a cooler reheater (heat exchanger) to obtain the dried air, which goes through to the outlet side. Evaporation thermometer Compressed air outlet Cooler re-heater Ball valve Auto drain Capillary tube High pressure switch Volume control valve Pressure switch Drain outlet Accumulator Compressor...
Open the catalog to page 8IDFA Series Optional Accessories Foundation Bolt Set Piping Adapter For fixing the air dryer to the foundations. Easy to secure by striking the axle. E (Width across flats) For converting the thread type of an IN/ OUT fitting for air dryers. Female thread B side Male thread A side Nominal thread size Stainless steel Thread type and port size Male thread A side Female thread B side Weight: 5 kg Compressed air inlet Rc1 (405) Compressed air outlet Rc1 Max. operating pressure: 1.0 MPa ∗ Not applicable to the moderate pressure specification Prepare a bypass piping set suitable for the...
Open the catalog to page 9IDFA Series Option symbol Cool compressed air output Cool outlet air (10 °C) can be supplied. The air flow with this option is smaller than that of the standard air dryer. (Refer to the table below.) If the air dryer is used out of the scope of the rated specifications or conditions, select a model according to page 4 and apply the air flow capacity shown in the table below to the data D. Option symbol With a heavy-duty auto drain (applicable to moderate pressure) The float type auto drain used in the standard air dryer is replaced with a heavy-duty auto drain (ADH 4 0 0 0 - 0 4 ) which enables...
Open the catalog to page 10All SMC catalogs and technical brochures
-
Serie HRR
64 Pages
-
Série VP/VG
33 Pages
-
Série XL
27 Pages
-
Série ACG/ARG/AWG
45 Pages
-
Série JXC5H/6H
36 Pages
-
LEJS100-X400 series
15 Pages
-
JMB series
13 Pages
-
JCM series
21 Pages
-
PF3A7*H
40 Pages
-
PF3W
34 Pages
-
Compact Guide Cylinder with Lock
36 Pages
-
Water Treatment
16 Pages
-
Food & Packaging Industry
4 Pages
-
Digital Gap Checker
26 Pages
-
Vacuum Pad
16 Pages
-
One-touch Fittings
224 Pages
-
Soft Start-up Valve
16 Pages
-
Electric Actuator
272 Pages
-
Rotary Actuator
40 Pages
-
Compact Guide Cylinder
18 Pages
-
Compact Slide
24 Pages
-
Air Cylinder
124 Pages
-
LEFB, LEFG-BS series
180 Pages
-
JMGP series
16 Pages
-
ISO Cylinder
32 Pages
-
IZD10
20 Pages
-
IZH10
8 Pages
-
Fan Type Lonizer
28 Pages
-
Check Valves
4 Pages
-
Compact Cylinder/Clean series
16 Pages
-
3 port solenoid Valve
74 Pages
-
Vacuum Ejector Series ZM
20 Pages
-
Series ZL
20 Pages
-
Series CM2
92 Pages
-
Series IDGA/IDG
56 Pages
-
Platform Cylinder Series CXT
14 Pages
-
IDH-A
12 Pages
-
CP96-C96-B
74 Pages
-
CVQ
24 Pages
-
HY
52 Pages
-
VNA
10 Pages
-
Series MXY
28 Pages
-
Series MXP
39 Pages
-
Air Slide Table
132 Pages
-
Compact Cylinder Series CQ2
138 Pages
-
S0700
112 Pages
-
SYJ
96 Pages
-
SY - NEW
164 Pages
-
VF
60 Pages
-
C(D)55 series
24 Pages
-
C(D)Q2 series
216 Pages
-
MGP series
36 Pages
-
11-LEFS series
19 Pages
-
LECS series
16 Pages
-
LECPA series
4 Pages
-
KQ series
80 Pages
-
IDF series
16 Pages
-
ZP series
69 Pages
-
MHF series
32 Pages
-
MHZ series
68 Pages
-
CRB series
44 Pages
-
MGJ series
7 Pages
-
AC series
98 Pages
-
VH series
14 Pages
-
LVA series
43 Pages
-
VDW series
28 Pages
-
LVM series
28 Pages
-
VX2 series
32 Pages
-
MXH series
32 Pages
-
MXF series
12 Pages
-
CXW series
48 Pages
-
CXS series
76 Pages
-
CQS series
40 Pages
-
CQM series
28 Pages
-
CLQ series
36 Pages