video corpo cad

PF3A7*H
40Pages

{{requestButtons}}

Catalog excerpts

PF3A7*H - 1

Digital Flow Switch for Large Flow A wide range of flow measurement is possible with 1 product. ∗2 The flow ratio is 20 : 1 for the existing model (PF2A7२H/Large flow type). Port size Modular Connection Applicable flow range [l/min] 2000 3000 6000 ∗ The port sizes in ( ) are for when a piping adapter (sold separately) is connected The flow rate value and the device status can be figured out easily via the process data. p. 3 Diagnosis items Over current error, Rated/Accumulated flow error, Flow/ Temperature sensor failure, Internal product malfunction Improved resistance to moisture and foreign matter The bypass construction reduces sensor accuracy deterioration and damage. p. 1 New The modular type has been added. New Can be connected to the air combination p. 4 Digital Flow Monitor Allows for the monitoring of remote lines e li

Open the catalog to page 1
PF3A7*H - 2

Digital Flow Switch for Large Flow PF3A7 २H(-L) Series Improved resistance to moisture and foreign matter The bypass construction reduces the moist air or foreign matter in contact with the sensor, reducing sensor accuracy deterioration and damage. Sensor unit Through bore construction • Pressure loss: 75 % reduction∗2 (20 kPa / 5 kPa) Bypass construction • Maintenance-free fluid passage Air containing moisture or foreign matter ∗1 Excludes the modular type ∗2 Compared with the existing model (PF2A7२H/ Large flow type) ∗ 2-screen display: 2-row display of main screen and sub screen Upper...

Open the catalog to page 2
PF3A7*H - 3

Digital Flow Switch for Large Flow PF3A7 २H(-L) Series Smallest settable increment: 2 l/min ∗ For the PF3A703H ∗ 5 l/min for the existing model (PF2A703H/Large flow type) Functions p. 33, 34 ¡Output operation ¡Simple setting mode ¡Display colour ¡Reference condition ¡Response time ¡FUNC output switching function (Analogue output ⇔ External input) ¡Selectable analogue output function ¡External input function ¡Forced output function ¡Accumulated value hold Application ¡Peak/Bottom value display ¡Display OFF mode ¡Setting of security code ¡Key-lock function ¡Reset to the default settings...

Open the catalog to page 3
PF3A7*H - 4

Digital Flow Switch for Large Flow Supports the IO-Link communication protocol Configuration File (IODD File∗1) · Manufacturer · Product part no. · Set value ∗1 IODD File: IODD is an abbreviation of IO Device Description. This file is necessary for setting the device and connecting it to a master. Save the IODD file on the PC to be used to set the device prior to use. Device settings can be set by the master. ter Read the device data. • Switch ON/OFF signal and analogue value • Device information: Manufacturer, Product part number, Serial number, etc. • Normal or abnormal device status •...

Open the catalog to page 4
PF3A7*H - 5

Modular Type Digital Flow Switch PF3A701H/702H(-L) Series 3-Colour Display Flow range Air Combination Connection Examples ˾ For the AC30B-D + PF3A701H Air filter Products do not come assembled. They should be ordered separately and assembled by the customer. Flow switch Spacer with bracket Filter regulator Flow switch Spacer with bracket Piping adapter Piping adapter Simple Specials System Unit with F.R.L is available with the simple special ordering system. The lead time is almost the same as the standard product. Please contact your local sales representative for more details. ˾ A right to...

Open the catalog to page 5
PF3A7*H - 6

Digital Flow Monitor Allows for the monitoring of remote lines PF3A7२H Centralized flow control The flow rate of a flow switch installed in a distant location can be confirmed! Visualisation of settings The sub screen (label) shows the item to be set. Existing model Hysteresis mode Mode Examples Normal output New PFG300 Switches between displays Set value (Threshold value) Reversed output Set value (Threshold value) Window comparator mode Normal output/Lo side Set value (Threshold value) Normal output/Hi side Reversed output/Lo side Set value (Threshold value) Always displayed on one screen...

Open the catalog to page 6
PF3A7*H - 7

Digital Flow Monitor PFG300 Series NPN/PNP switch function Input range selection (for Pressure/Flow rate) The number of stock items can be reduced. The displayed value to the sensor input can be set as required. (Voltage input: 1 to 5 V/Current input: 4 to 20 mA) Display Pressure switch/Flow switch can be displayed. A 5V Voltage input 1 V Current input 4 mA 20 mA Analogue output of 0 to 10 V is also available. A is displayed for 1 V (or 4 mA). B is displayed for 5 V (or 20 mA). The range can be set as required. ˾ Pressure Sensor for General Fluids/PSE570 1000 Voltage output Current output...

Open the catalog to page 7
PF3A7*H - 8

Digital Flow Switch for Large Flow PF3A7 २H(-L) Series Flow Switch Flow Rate Variations Series Compatibility with the PFG300 digital flow monitor Applicable Detection Smallest settable fluid method increment Thermal type 1 l/min (Thermistor) 2 l/min Thermal 5 l/min type (Platinum sensor) 10 l/min Large flow type Large flow type Bypass 1 l/min flow type Large flow type p. 11, 13 Large flow type Modular type Modular type Dry air Thermal N2 type Ar (MEMS) CO2 Thermal type Dry air (MEMS) 1 l/min N2 PFG300 Bypass flow type Thermal type Dry air (MEMS) 1 l/min PFG300 N2 Bypass flow type Applicable...

Open the catalog to page 8
PF3A7*H - 9

Digital Flow Switch for Large Flow PF3A7 २H(-L) Series Flow Switch Variations / Basic Performance Table Power supply voltage Temperature characteristics (25 °C standard) ±2 % F.S. Monitor unit: (Fluid: Dry air) ±0.1 % F.S. Analogue output: Analogue output: ±0.3 % F.S. ±5 % F.S. ±1 % F.S. Monitor unit: (Fluid: Dry air) ±0.1 % F.S. ±1 % F.S. Monitor unit: (Fluid: Dry air) ±0.1 % F.S. Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode: Variable Window...

Open the catalog to page 9
PF3A7*H - 11

CONTENTS 3-Colour Display 3-Colour Display Digital Flow Switch PF3A7 २H Series IO-Link Compatible Large Flow Type Digital Flow Switch PF3A7 २H-L Series Modular Type Digital Flow Switch PF3A7 २H Series IO-Link Compatible Modular Type Digital Flow Switch PF3A7 २H-L Series Digital Flow Monitor PFG300 Series Large Flow Type 3-Colour Display Large Flow Type Digital Flow Switch PF3A7२H Series How to Order ································································································································ p. 11 Specifications...

Open the catalog to page 11

All SMC catalogs and technical brochures

  1. Serie HRR

    64 Pages

  2. Série VP/VG

    33 Pages

  3. Série XL

    27 Pages

  4. JMB series

    13 Pages

  5. JCM series

    21 Pages

  6. PF3W

    34 Pages

  7. Vacuum Pad

    16 Pages

  8. Compact Slide

    24 Pages

  9. Air Cylinder

    124 Pages

  10. JMGP series

    16 Pages

  11. ISO Cylinder

    32 Pages

  12. IZD10

    20 Pages

  13. IZH10

    8 Pages

  14. Check Valves

    4 Pages

  15. Series ZL

    20 Pages

  16. Series CM2

    92 Pages

  17. IDH-A

    12 Pages

  18. CP96-C96-B

    74 Pages

  19. CVQ

    24 Pages

  20. HY

    52 Pages

  21. VNA

    10 Pages

  22. Series MXY

    28 Pages

  23. Series MXP

    39 Pages

  24. Air Slide Table

    132 Pages

  25. S0700

    112 Pages

  26. SYJ

    96 Pages

  27. SY - NEW

    164 Pages

  28. VF

    60 Pages

  29. C(D)55 series

    24 Pages

  30. C(D)Q2 series

    216 Pages

  31. MGP series

    36 Pages

  32. 11-LEFS series

    19 Pages

  33. LECS series

    16 Pages

  34. LECPA series

    4 Pages

  35. KQ series

    80 Pages

  36. IDF series

    16 Pages

  37. ZP series

    69 Pages

  38. MHF series

    32 Pages

  39. MHZ series

    68 Pages

  40. CRB series

    44 Pages

  41. MGJ series

    7 Pages

  42. AC series

    98 Pages

  43. VH series

    14 Pages

  44. LVA series

    43 Pages

  45. VDW series

    28 Pages

  46. LVM series

    28 Pages

  47. VX2 series

    32 Pages

  48. MXH series

    32 Pages

  49. MXF series

    12 Pages

  50. CXW series

    48 Pages

  51. CXS series

    76 Pages

  52. CQS series

    40 Pages

  53. CQM series

    28 Pages

  54. CLQ series

    36 Pages

Archived catalogs

  1. KR

    7 Pages

  2. KF

    16 Pages

  3. AFF

    80 Pages

  4. HAA

    3 Pages

  5. ZFA

    14 Pages

  6. ZA

    13 Pages

  7. D

    117 Pages

  8. RB

    23 Pages

  9. cep

    44 Pages

  10. rsq

    30 Pages

  11. CLK

    51 Pages

  12. MK

    20 Pages

  13. CLJ

    65 Pages

  14. ARG

    48 Pages

  15. VXA

    17 Pages

  16. MXU

    12 Pages