Group: SMC
Catalog excerpts
Handheld Electrostatic Meter Easy-to-use handheld electrostatic meter Rated charge amount range: ± Minimum display unit: Compact & Lightweight: 85g (excluding dry dell batteries) Peak & Bottom display function Zero clear function Auto power-off function LOW battery indicator Backlight for reading in the dark
Open the catalog to page 1Handheld Electrostatic Meter High-voltage measuring handle ∗ The ground wire and soft case Accessories and Options / Part Numbers for Individual Parts Ground wire (1.5 m) / Accessories Soft case / Accessories High-voltage measuring handle / Option High-voltage measuring handle kV 0.0 ±2 ion tens Ex tial at ten -OFF nds Po Exte in ed WER 15m asur ess splay Me TO PO Pr6sec E Di for AU ss! MOD Pre R WE OM POWER Bottom PO TT ss! / BO Pre AK k ER Pea POW PE G 6 mal 2 LR Nor Vx AN Y 1.5 JAP IN ER TT MADE BA Ground wire Soft case Rated charge amount range Minimum display unit Measurement distance...
Open the catalog to page 2Handheld Electrostatic Meter Dimensions (Unit: mm) Display part Measured Potential AUTO POWER-OFF Extension Press Extends at for 6sec POWER 15min PEAK / BOTTOM MODE Display POWER Normal Press! Bottom BEST DETECTING POSITION 50mm Do not apply a strong impact on the sensing part. Sensor part BEST DETECTING POSITION 50mm
Open the catalog to page 3Series IZH10 Names and Functions of Individual Parts LCD display • Charged electricity display • Peak/bottom value display Peak display “P” Bottom display “b” Measured Potential AUTO POWER-OFF Extension Press Extends at for 6sec POWER 15min PEAK / BOTTOM MODE Display POWER Normal Ground terminal Press! Bottom BATTERY 1.5V x 2 LR6 MADE IN JAPAN Battery LOW “L” LIGHT button • Backlight ON/OFF POWER button • Power ON/OFF • Mode switching Function Details A Peak/Bottom display function The function constantly detects and updates the maximum and minimum electrostatic potential value and allows...
Open the catalog to page 4Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of “Caution”, “Warning” or “Danger”. To ensure safety, be sure to observe ISO 4414 Note 1) and other safety practices. Caution : Warning : Danger : Operator error could result in injury or equipment damage. Operator error could result in serious injury or loss of life. In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 4414 : Pneumatic fluid power --General rules...
Open the catalog to page 5Handheld Electrostatic Meter Precautions Be sure to read this before handling. Refer to the back page 1 for Safety Precautions. Handling Precautions Warning 1. Do not make any modifications (including exchanging the printed circuit board) to the product. It may cause human injuries and damage. 2. Use the device in the specified range. Using it out of the specified range may result in fires, electric shock, or damage. Confirm the specifications before using. 3. Measurement near high-voltage Avoid measuring near high-voltage exceeding specifications as it can be dangerous. 4. Handling of...
Open the catalog to page 6EUROPEAN SUBSIDIARIES: Austria SMC Pneumatik GmbH (Austria). Girakstrasse 8, A-2100 Korneuburg Phone: +43 2262-62280, Fax: +43 2262-62285 E-mail: office@smc.at http://www.smc.at France SMC Pneumatique, S.A. 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: contact@smc-france.fr http://www.smc-france.fr Netherlands SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam Phone: +31 (0)20-5318888, Fax: +31 (0)20-5318880 E-mail: info@smcpneumatics.nl http://www.smcpneumatics.nl Spain...
Open the catalog to page 8All SMC catalogs and technical brochures
-
Serie HRR
64 Pages
-
Série VP/VG
33 Pages
-
Série XL
27 Pages
-
Série ACG/ARG/AWG
45 Pages
-
Série JXC5H/6H
36 Pages
-
LEJS100-X400 series
15 Pages
-
JMB series
13 Pages
-
JCM series
21 Pages
-
PF3A7*H
40 Pages
-
PF3W
34 Pages
-
Compact Guide Cylinder with Lock
36 Pages
-
Water Treatment
16 Pages
-
Food & Packaging Industry
4 Pages
-
Digital Gap Checker
26 Pages
-
Vacuum Pad
16 Pages
-
One-touch Fittings
224 Pages
-
Soft Start-up Valve
16 Pages
-
Electric Actuator
272 Pages
-
Rotary Actuator
40 Pages
-
Compact Guide Cylinder
18 Pages
-
Compact Slide
24 Pages
-
Air Cylinder
124 Pages
-
LEFB, LEFG-BS series
180 Pages
-
JMGP series
16 Pages
-
ISO Cylinder
32 Pages
-
IZD10
20 Pages
-
Fan Type Lonizer
28 Pages
-
Check Valves
4 Pages
-
Compact Cylinder/Clean series
16 Pages
-
3 port solenoid Valve
74 Pages
-
Vacuum Ejector Series ZM
20 Pages
-
Series ZL
20 Pages
-
Series CM2
92 Pages
-
Series IDGA/IDG
56 Pages
-
Platform Cylinder Series CXT
14 Pages
-
IDH-A
12 Pages
-
CP96-C96-B
74 Pages
-
CVQ
24 Pages
-
HY
52 Pages
-
VNA
10 Pages
-
Series MXY
28 Pages
-
Series MXP
39 Pages
-
Air Slide Table
132 Pages
-
Compact Cylinder Series CQ2
138 Pages
-
S0700
112 Pages
-
SYJ
96 Pages
-
SY - NEW
164 Pages
-
VF
60 Pages
-
C(D)55 series
24 Pages
-
C(D)Q2 series
216 Pages
-
MGP series
36 Pages
-
11-LEFS series
19 Pages
-
LECS series
16 Pages
-
LECPA series
4 Pages
-
KQ series
80 Pages
-
IDF series
16 Pages
-
ZP series
69 Pages
-
MHF series
32 Pages
-
MHZ series
68 Pages
-
CRB series
44 Pages
-
MGJ series
7 Pages
-
AC series
98 Pages
-
VH series
14 Pages
-
LVA series
43 Pages
-
VDW series
28 Pages
-
LVM series
28 Pages
-
VX2 series
32 Pages
-
MXH series
32 Pages
-
MXF series
12 Pages
-
CXW series
48 Pages
-
CXS series
76 Pages
-
CQS series
40 Pages
-
CQM series
28 Pages
-
CLQ series
36 Pages