With air temperature adjustment function Stable supply of temperature and pressure controlled dry clean air! Possible to supply compressed Application example Air bearing air with the same conditions Supplying compressed air with constant conditions to and quality regardless of the air bearings mounted on the tool. season. Air flow capacity (l/min[ANR]) IDH4 : 100 to 500 IDH6 : 200 to 800 Machine tool Outlet air temperature adjustment range: Temperature control (Heater) Pressure regulation (Regulator) Dehumidification (Dryer) (possible to extend depending on the conditions) Outlet air temperature stability: Outlet air set pressure range: Outlet air pressure dew point: Nominal filtration rating: Cleaning (Filter) Outlet oil mist concentration: Outlet cleanliness: Particles of 0.3 µm or more: 3.5 particles/l [ANR] or less ∗1 Performance when the operation of each part is stable without fluctuations in operating conditions and power supply. ∗2 Performance of the built-in filter, which depends on the inlet air conditions. Power supply available all over the world Model Air flow capacity (l/min [ANR]) Outlet air temperature Outlet air set Outlet air temperature adjustment range (°C) pressure range (MPa) stability (°C) 15 to 30 Filter nominal filtration rating Temperature control method Heater operation PID control
Open the catalog to page 1Thermo-dryer Compact, Space saving Installation close to a wall is possible. Wall Installation close to a wall is possible with the ventilation holes on the front and top sides. Ventilation hole Dimensions in brackets indicate for IDHȞ6. Unit: mm Convenient Functions Power failure auto-restart function Control temperature failure alarm Even if operation is stopped by unexpected power failure, once the power supply is recovered, the operation will start automatically. If the temperature exceeds the set temperature by an arbitrary amount, an error signal will be generated. ∗If an instantaneous...
Open the catalog to page 2Remote operation, stop, error signal output functions are provided. It is possible to achieve centralised control in a factory with remote operation, stop and error signal output functions. It is possible to operate and stop the dryer remotely. (Note that the dryer should be rested for at least 3 minutes after it is stopped, and should be operated for at least 10 minutes continuously.) ¡ It is possible to receive operation and error signals. ¡ It is possible to synchronise the operation of the dryer with the external air compressor operation to prevent people from forgetting to turn it off and...
Open the catalog to page 3Model Selection The settable range of the outlet air set temperature varies depending on the operating conditions. Be sure to select the model in accordance with the selection method below. Condition Inlet air temperature 20°C Ambient temperature Outlet air pressure dew point Outlet air set temperature Air flow Condition Inlet air temperature 30°C Ambient temperature Outlet air pressure dew point IDH२4 or IDH२6 are selected from Data E . Move to Step 2 . Read the correction factors. IDH२4 or IDH२6 are selected from Data E . Move to Step 2 . Input the operating conditions in the table below and...
Open the catalog to page 4Model Selection Series Condition Inlet air temperature 25°C Condition Inlet air temperature 30°C Ambient temperature Outlet air pressure dew point Ambient temperature Outlet air pressure dew point Outlet air set temperature Air flow IDH२6 is selected from Data E . Move to Step 2 . Air flow of 80 l/min is outside of the range of air flow capacity. Input the operating conditions in the table below and read the correction factors from the tables of Data A to D . Condition Inlet air temperature Ambient temperature Outlet air pressure dew point Data symbol Correction factor A 1.24 Condition Inlet...
Open the catalog to page 5Size Size Rated air flow capacity 400 l/min [ANR] 600 l/min [ANR] Combination of built-in products Voltage Symbol Option symbol Super mist separator · Nominal filtration rating: 0.01 µm (99.9% filtration efficiency) · Outlet oil mist concentration: MAX. 0.01 mg/m3 [ANR] (≈0.008 ppm) · Outlet oil mist concentration: Particles of 0.3 µm or more: 3.5 particles/l [ANR] or less Auto drain normally closed Filterባ (AME) The auto drain which exhausts dehumidified drainage and the auto drain on the built-in filter are changed to the "normally closed" specification. Recommended for small flow rate (100...
Open the catalog to page 6Thermo-dryer Series Standard Specifications Model Fluid Air flow capacity Inlet air temperature Inlet air pressure Ambient temperature Outlet air temperature adjustment range 200 to 800 l/min [ANR] 5 to 40°C Note1) 2) 0.3 to 1.0 MPa Operating range 15 to 35°C (Relative humidity 85% or less) 15 to 30°C 0.15 to 0.85 MPa Outlet air set pressure range (The inlet air pressure should be at least 0.15 MPa higher than the outlet air pressure.) Air flow capacity 400 l/min [ANR] 600 l/min [ANR] Inlet air pressure 0.7 MPa Inlet air temperature 35°C Rated conditions Ambient temperature 30°C Outlet air set...
Open the catalog to page 7Dimensions IDH२4 Temperature controller Pressure adjustment handle Ventilation direction Illuminated switch Evaporation thermometer Filter maintenance port Terminal block Ventilation direction Signal cable outlet (ø17) Grommet with membrane Signal cable outlet (ø17) Grommet with membrane Drain pipe fitting (Applicable tube O.D. ø10) Ventilation air inlet (With dustproof filter) Pressure adjustment handle Ventilation direction Illuminated switch Evaporation thermometer Ventilation direction Filter maintenance port Terminal block Signal cable outlet (ø17) Grommet with membrane Signal cable outlet...
Open the catalog to page 8Condensed Water Calculation Amount of condensed water C−H 20 18.2−3.0=15.2 g/m3 C Ambient temperature (Air compressor intake air temperature) (°C) How to calculate the amount of condensed water Dew Point Conversion Chart 60 50 Atmospheric pressure dew point (°C) How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point 10°C and a pressure 0.7 MPa. 1. Trace the arrow mark Ǟ starting from the point A at a pressure dew point 10°C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark Ǟ starting...
Open the catalog to page 96 Pages
64 Pages
33 Pages
27 Pages
45 Pages
36 Pages
15 Pages
13 Pages
21 Pages
40 Pages
34 Pages
36 Pages
16 Pages
4 Pages
26 Pages
16 Pages
224 Pages
16 Pages
272 Pages
40 Pages
18 Pages
24 Pages
124 Pages
180 Pages
16 Pages
32 Pages
20 Pages
8 Pages
28 Pages
4 Pages
16 Pages
74 Pages
20 Pages
20 Pages
92 Pages
56 Pages
14 Pages
74 Pages
24 Pages
52 Pages
10 Pages
28 Pages
39 Pages
132 Pages
138 Pages
112 Pages
96 Pages
164 Pages
60 Pages
24 Pages
216 Pages
36 Pages
19 Pages
16 Pages
4 Pages
80 Pages
16 Pages
69 Pages
32 Pages
68 Pages
44 Pages
7 Pages
98 Pages
14 Pages
43 Pages
28 Pages
28 Pages
32 Pages
32 Pages
12 Pages
48 Pages
76 Pages
40 Pages
28 Pages
36 Pages