IDH-A
1 /12Pages

IDH-A

IDH-A
1 /12Pages

Catalog excerpts

IDH-A-1

With air temperature adjustment function Stable supply of temperature and pressure controlled dry clean air! Possible to supply compressed Application example Air bearing air with the same conditions Supplying compressed air with constant conditions to and quality regardless of the air bearings mounted on the tool. season. Air flow capacity (l/min[ANR]) IDH4 : 100 to 500 IDH6 : 200 to 800 Machine tool Outlet air temperature adjustment range: Temperature control (Heater) Pressure regulation (Regulator) Dehumidification (Dryer) (possible to extend depending on the conditions) Outlet air temperature stability: Outlet air set pressure range: Outlet air pressure dew point: Nominal filtration rating: Cleaning (Filter) Outlet oil mist concentration: Outlet cleanliness: Particles of 0.3 µm or more: 3.5 particles/l [ANR] or less ∗1 Performance when the operation of each part is stable without fluctuations in operating conditions and power supply. ∗2 Performance of the built-in filter, which depends on the inlet air conditions. Power supply available all over the world Model Air flow capacity (l/min [ANR]) Outlet air temperature Outlet air set Outlet air temperature adjustment range (°C) pressure range (MPa) stability (°C) 15 to 30 Filter nominal filtration rating Temperature control method Heater operation PID control

 Open the catalog to page 1
IDH-A-2

Thermo-dryer Compact, Space saving Installation close to a wall is possible. Wall Installation close to a wall is possible with the ventilation holes on the front and top sides. Ventilation hole Dimensions in brackets indicate for IDHȞ6. Unit: mm Convenient Functions Power failure auto-restart function Control temperature failure alarm Even if operation is stopped by unexpected power failure, once the power supply is recovered, the operation will start automatically. If the temperature exceeds the set temperature by an arbitrary amount, an error signal will be generated. ∗If an instantaneous...

 Open the catalog to page 2
IDH-A-3

Remote operation, stop, error signal output functions are provided. It is possible to achieve centralised control in a factory with remote operation, stop and error signal output functions. It is possible to operate and stop the dryer remotely. (Note that the dryer should be rested for at least 3 minutes after it is stopped, and should be operated for at least 10 minutes continuously.) ¡ It is possible to receive operation and error signals. ¡ It is possible to synchronise the operation of the dryer with the external air compressor operation to prevent people from forgetting to turn it off and...

 Open the catalog to page 3
IDH-A-4

Model Selection The settable range of the outlet air set temperature varies depending on the operating conditions. Be sure to select the model in accordance with the selection method below. Condition Inlet air temperature 20°C Ambient temperature Outlet air pressure dew point Outlet air set temperature Air flow Condition Inlet air temperature 30°C Ambient temperature Outlet air pressure dew point IDH२4 or IDH२6 are selected from Data E . Move to Step 2 . Read the correction factors. IDH२4 or IDH२6 are selected from Data E . Move to Step 2 . Input the operating conditions in the table below and...

 Open the catalog to page 4
IDH-A-5

Model Selection Series Condition Inlet air temperature 25°C Condition Inlet air temperature 30°C Ambient temperature Outlet air pressure dew point Ambient temperature Outlet air pressure dew point Outlet air set temperature Air flow IDH२6 is selected from Data E . Move to Step 2 . Air flow of 80 l/min is outside of the range of air flow capacity. Input the operating conditions in the table below and read the correction factors from the tables of Data A to D . Condition Inlet air temperature Ambient temperature Outlet air pressure dew point Data symbol Correction factor A 1.24 Condition Inlet...

 Open the catalog to page 5
IDH-A-6

Size Size Rated air flow capacity 400 l/min [ANR] 600 l/min [ANR] Combination of built-in products Voltage Symbol Option symbol Super mist separator · Nominal filtration rating: 0.01 µm (99.9% filtration efficiency) · Outlet oil mist concentration: MAX. 0.01 mg/m3 [ANR] (≈0.008 ppm) · Outlet oil mist concentration: Particles of 0.3 µm or more: 3.5 particles/l [ANR] or less Auto drain normally closed Filterባ (AME) The auto drain which exhausts dehumidified drainage and the auto drain on the built-in filter are changed to the "normally closed" specification. Recommended for small flow rate (100...

 Open the catalog to page 6
IDH-A-7

Thermo-dryer Series Standard Specifications Model Fluid Air flow capacity Inlet air temperature Inlet air pressure Ambient temperature Outlet air temperature adjustment range 200 to 800 l/min [ANR] 5 to 40°C Note1) 2) 0.3 to 1.0 MPa Operating range 15 to 35°C (Relative humidity 85% or less) 15 to 30°C 0.15 to 0.85 MPa Outlet air set pressure range (The inlet air pressure should be at least 0.15 MPa higher than the outlet air pressure.) Air flow capacity 400 l/min [ANR] 600 l/min [ANR] Inlet air pressure 0.7 MPa Inlet air temperature 35°C Rated conditions Ambient temperature 30°C Outlet air set...

 Open the catalog to page 7
IDH-A-8

Dimensions IDH२4 Temperature controller Pressure adjustment handle Ventilation direction Illuminated switch Evaporation thermometer Filter maintenance port Terminal block Ventilation direction Signal cable outlet (ø17) Grommet with membrane Signal cable outlet (ø17) Grommet with membrane Drain pipe fitting (Applicable tube O.D. ø10) Ventilation air inlet (With dustproof filter) Pressure adjustment handle Ventilation direction Illuminated switch Evaporation thermometer Ventilation direction Filter maintenance port Terminal block Signal cable outlet (ø17) Grommet with membrane Signal cable outlet...

 Open the catalog to page 8
IDH-A-9

Condensed Water Calculation Amount of condensed water C−H 20 18.2−3.0=15.2 g/m3 C Ambient temperature (Air compressor intake air temperature) (°C) How to calculate the amount of condensed water Dew Point Conversion Chart 60 50 Atmospheric pressure dew point (°C) How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point 10°C and a pressure 0.7 MPa. 1. Trace the arrow mark Ǟ starting from the point A at a pressure dew point 10°C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark Ǟ starting...

 Open the catalog to page 9

All SMC catalogs and technical brochures

  1. Serie HRR

    64  Pages

  2. Série VP/VG

    33  Pages

  3. Série XL

    27  Pages

  4. Série JXC5H/6H

    36  Pages

  5. JMB series

    13  Pages

  6. JCM series

    21  Pages

  7. PF3A7*H

    40  Pages

  8. PF3W

    34  Pages

  9. Water Treatment

    16  Pages

  10. Vacuum Pad

    16  Pages

  11. Rotary Actuator

    40  Pages

  12. Compact Slide

    24  Pages

  13. Air Cylinder

    124  Pages

  14. JMGP series

    16  Pages

  15. ISO Cylinder

    32  Pages

  16. IZD10

    20  Pages

  17. IZH10

    8  Pages

  18. Check Valves

    4  Pages

  19. Series ZL

    20  Pages

  20. Series CM2

    92  Pages

  21. Series IDGA/IDG

    56  Pages

  22. CP96-C96-B

    74  Pages

  23. CVQ

    24  Pages

  24. HY

    52  Pages

  25. VNA

    10  Pages

  26. Series MXY

    28  Pages

  27. Series MXP

    39  Pages

  28. Air Slide Table

    132  Pages

  29. S0700

    112  Pages

  30. SYJ

    96  Pages

  31. SY - NEW

    164  Pages

  32. VF

    60  Pages

  33. C(D)55 series

    24  Pages

  34. C(D)Q2 series

    216  Pages

  35. MGP series

    36  Pages

  36. 11-LEFS series

    19  Pages

  37. LECS series

    16  Pages

  38. LECPA series

    4  Pages

  39. KQ series

    80  Pages

  40. IDF series

    16  Pages

  41. ZP series

    69  Pages

  42. MHF series

    32  Pages

  43. MHZ series

    68  Pages

  44. CRB series

    44  Pages

  45. MGJ series

    7  Pages

  46. AC series

    98  Pages

  47. VH series

    14  Pages

  48. LVA series

    43  Pages

  49. VDW series

    28  Pages

  50. LVM series

    28  Pages

  51. VX2 series

    32  Pages

  52. MXH series

    32  Pages

  53. MXF series

    12  Pages

  54. CXW series

    48  Pages

  55. CXS series

    76  Pages

  56. CQS series

    40  Pages

  57. CQM series

    28  Pages

  58. CLQ series

    36  Pages

Archived catalogs

  1. KR

    7  Pages

  2. KF

    16  Pages

  3. AFF

    80  Pages

  4. HAA

    3  Pages

  5. ZFA

    14  Pages

  6. ZA

    13  Pages

  7. D

    117  Pages

  8. RB

    23  Pages

  9. cep

    44  Pages

  10. rsq

    30  Pages

  11. CLK

    51  Pages

  12. MK

    20  Pages

  13. CLJ

    65  Pages

  14. ARG

    48  Pages

  15. VXA

    17  Pages

  16. MXU

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.