Refrigerateci Air Dryer Large Size Series New temperature environment! the large air-cooled type Ambient temperature 45°C at max. [Conventional large type: 40°C] Inlet air temperature 60°C at max. [Conventional large type: 50°C] Energy Saving design with secondary heater (SMC's original new design!) Exhaust heat reduced by 25% at max. (12 kw—9 kW)^o Ambient temperature increase suppressed (Air-cooled type) Facility water reduced (Water-cooled type) Employs a heat exchanger made of high corrosion-resistant stainless steel. •Dustproof filter •With a lamp to indicate when to check the dustproof filter •Only access from front side is required to check electrical equipment [Patent Pending] [Air-cooled type] Exhausting direction four directions!! Space saving One side can be installed flat Installation space reduced by Air-cooled type [Water-cooled type] , Facility water piping port Rated inlet Standard condition Compressor intake
Open the catalog to page 1Refrigerated Air Dryer Tolerant of high temperature environment (ambient temperature 45 C), Energy saving design! Air-cooled type can be used at ambient temperature 45 C. Secondary heater helps the heat radiation of the condenser allows use at ambient temperature 45 C. New dryer Conventional dryer It cannot radiate heat if the ambient temperature is excessive. Compressed Secondary heater cools the refrigerant and air outlet reduces the load to the It is warmed by condenser. the secondary heater, preventing condensation of the piping on the outlet side. Secondary heater Condenser Compressor for...
Open the catalog to page 2• Dustproof filter Dustproof filter • Only access from front side is required to check electrical equipment and dustproof filter. [Air-cooled type] Exhausting direction can be selected from four directions!! Auto drain tube can be connected in two directions, left or right. [Water-cooled type] Facility water piping port Facility water outlet Facility water inlet Facility water outlet Facility water inlet Avoid exhausting air onto adjacent Temperature control (Space saving). Either the left or right can be installed flat against a wall! Note) Installation space reduced by Note) For air-cooled...
Open the catalog to page 3Model Selection The corrected air flow capacity, which considers the user's operating conditions, is required for selecting air dryer. Select using the following procedures. Obtain the correction factors © to ® suitable for your operating condition from the below table. Note) Values obtained from the below "Correction Factors" Max. coefficient value is 1.5 Correction factor is 1.5 when the calculation result is 1.5 or greater. lair flow capacity. Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air flow rate -r (correction factor©x©x©x©] Corrected...
Open the catalog to page 4Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 60 C, Max. ambient temperature: 45 C) Note) Note that the above value is for reference only. Check the actual compressor capacity. Note 1) Enter alphabetically when multiple options are combined. Note 2) The following combination is not available. • The option B and heat exhausting direction 3 (Heat exhaust from the top cannot be achieved with easy outdoor installation Heat exhausting direction available. (Heat exhausting face can be specified on one side only.) Note) Note that the above value Is for reference only....
Open the catalog to page 5Standard Specifications: Air-cooled Type Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure 20°C, relative humidity 65%] Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure 32°C] Note 3) The operation range does not guarantee the use with normal air flow capacity. When operating conditions are different from the rated specifications, please select a model in accordance with Model Selection (page 1 ) Note 4) Install a circuit breaker with a sensitivity 30 mA. Replacement Parts Note 5) Part number of only the exhaust mechanism...
Open the catalog to page 6Standard Specifications: Water-cooled Type Note 1) Airflow capacity under the standard condition (ANR) [atmospheric pressure 20°C, relative humidity 65%] Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure 32°C] Note 3) The operation range does not guarantee the use with normal air flow capacity. When operating conditions are different from the rated specifications, please select a model in accordance with Model Selection (page 1). Note 4) Facility water flow rate that satisfies the conditions in which the facility water inlet temperature is 32°C and the...
Open the catalog to page 7Series IDF100F/125F/150F Dimensions IDF100F: Air-cooled type 670 1120 Ventilation air inlet Ventilation direction (When symbol 1 is specified.) 4 x Eyebolt I.D. 25 267 Ventilation direction (When no symbol is specified.) Ventilation direction 1375 1276 Ventilation direction (When symbol 2 is specified.) 460 51 335 Ventilation direction (When symbol 3 is specified.) Terminal block for power supply Ventilation direction 40 Terminal block for signal 20 712 2 752 64 700 75 Drain tube (O.D. ø10, Length approx. 2 m) (Can also be connected on the other side.) 107 1 Signal cable outlet (Electric wire...
Open the catalog to page 8Refrigerated Air Dryer Series IDF1 OOF/125F/150F Ventilation direction (When symbol 3 is specified.) Terminal block Terminal block Power cable holder (Electric wire diameter o18 to 023) Ventilation direction Ball valve Ventilation direction \ Heavy duty auto drain Drain tube (Electric wire diameter 017 oi Grommet with membrane (Can also be connected on the other side.) Facility water Terminal block Facility water Inlet Facility water \Facility water inlet Power cable holder (Electric wire diameter 0I8 to 023) Heavy duty auto drain (Electric wire diameter 0I7 or less) Grommet with membrane other...
Open the catalog to page 9Refer to "How to Order" page 2 for optional models. [Air-cooled (Water-coolec type only) type only) Easy outdoor installation specification It can be installed outdoors under the eaves of a building, by mounting louvers at the ventilation air inlet and on the side in the heat exhausting direction and drip proof covers over the switch, etc. However, the product should be installed in a location where it will not come into direct contact with rain or snow. (On the opposite side when ventilation from the left is specified.) Same dimensions as the standard specifications Anti-corrosive treatment...
Open the catalog to page 106 Pages
64 Pages
33 Pages
27 Pages
45 Pages
36 Pages
15 Pages
13 Pages
21 Pages
40 Pages
34 Pages
36 Pages
16 Pages
4 Pages
26 Pages
16 Pages
224 Pages
16 Pages
272 Pages
40 Pages
18 Pages
24 Pages
124 Pages
180 Pages
16 Pages
32 Pages
20 Pages
8 Pages
28 Pages
4 Pages
16 Pages
74 Pages
20 Pages
20 Pages
92 Pages
56 Pages
14 Pages
12 Pages
74 Pages
24 Pages
52 Pages
10 Pages
28 Pages
39 Pages
132 Pages
138 Pages
112 Pages
96 Pages
164 Pages
60 Pages
24 Pages
216 Pages
36 Pages
19 Pages
16 Pages
4 Pages
80 Pages
69 Pages
32 Pages
68 Pages
44 Pages
7 Pages
98 Pages
14 Pages
43 Pages
28 Pages
28 Pages
32 Pages
32 Pages
12 Pages
48 Pages
76 Pages
40 Pages
28 Pages
36 Pages