HY

HY
1 / 52 PagesView full catalog

HY

Product catalog summary
Overview: The document provides detailed information on the Hygienic Design Cylinder Series HY, which includes types such as HYB, HYC, HYQ, and HYG. These cylinders are designed for environments requiring high hygiene standards, offering water resistance and easy cleaning.
Specifications: Cylinders are available in bore sizes from 20 mm to 100 mm, featuring a flat, grooveless design. They use NBR and FKM for external seals and conform to ISO/VDMA standards, offering a fivefold increase in service life compared to conventional models.
Features: Notable features include a new scraper design, special grease-retaining coating, and optional plug bolt and external cover. They have a breathing port for environments with water dispersion but are not suitable for direct food contact.
Performance: Operating with air, the cylinders require a minimum pressure of 0.15 MPa and a maximum of 1.0 MPa, with a proof pressure of 1.5 MPa. They do not need lubrication and support piston speeds of 50 to 500 mm/s. Temperature ranges are 0 to 70°C without an auto switch and 0 to 60°C with one.
Ordering Information: Instructions include options for auto switches, grease types, and mounting brackets. Auto switches come in various models with lead wire lengths of 0.5 m, 3 m, and 5 m.
Construction and Materials: Components like rod cover, head cover, cylinder tube, piston, and piston rod are made from aluminum alloy and stainless steel. Replacement parts and seal kits are available for maintenance.
Applications: Suitable for high hygiene and water-resistant applications, such as food processing, though not for direct food contact.
Auto Switch Connections and Examples: The document explains potential malfunctions when connecting two switches in parallel and provides examples of switch connections with color-coded wiring and load configurations.
Specifications and Features: Details on auto switch models include wiring type, applicable load, power supply voltage, and other electrical specifications. It highlights oilproof vinyl heavy-duty cords and provides dimensions and weight for each model.
Operating Precautions: Users should consult SMC for non-water-based coolant liquids and ensure trained personnel handle pneumatic systems. Safety measures for maintenance and operation are outlined, including precautions for interlock circuits and surge voltage impacts.
Safety Instructions: System designers are responsible for ensuring compatibility and safety. Guidelines for safe maintenance and operation are provided, along with conditions for contacting SMC.
Exemption from Liability: SMC disclaims liability for damages from abnormal conditions, misuse, or operations outside specified ranges, and for damages from combining products with other devices or software.
Design and Selection Cautions: Users should confirm specifications and use products within specified ranges. Guidelines for wiring and switch placement are provided to prevent malfunctions.
Mounting and Adjustment: Proper mounting and adjustment instructions emphasize using appropriate screws and torque values to prevent damage.
See more

Catalog excerpts

HY-1

Hygienic Design Cylinder A water resistant cylinder configured for easy cleaning resistant configured ISO standard type Series HYC Basic type Series HYQ With guide Series HYG

 Open the catalog to page 1
HY-2

A water resistant cylinder c Scraper Flat, grooveless configuration Eliminates the auto switch groove and the holes for cushion needle holes, etc. Plug bolt (Optional) Conventional Cushion needle HYC Plug bolt (Optional) External cover (Optional) Five times increase in service life compared to conventional model (SMC ratio) Water-proof examination result (Reference data) 1 Hygienic Design Cylinder (HYB, HYQ, HYC, HYG) Water resistance improvement cylinder Comparison with conventional model: Approx. Standard cylinder Washing in water/Temperature: 30°C, Flow rate: 160 cc/min Grease for food (NSF-H1...

 Open the catalog to page 2
HY-3

onfigured for easy cleaning Plug bolt (Optional) New scraper Grease retention in guide rod and cylinder rod Breathing port on guide (PAT.) Water dispersion environment General environment Piping at the breathing port on guide allows breathing outside the water dispersion environment. Special coating (PAT.) Guide accommodates a special coating. Plug 2. Lower side mounting Application: Plug bolts are used to close the mounting hole not used. Mounting hole of the bottom surface is closed. Bore size 2. Lower side mounting Mounting hole of the top and bottom surface is closed. Mounting hole of the...

 Open the catalog to page 3
HY-4

Hygienic Design Cylinder Round Type Without auto switch With auto switch H7BAL Number of auto switches With auto switch (Built-in magnet) Auto switch Port thread type Nil TN TF Without auto switch (Built-in magnet) Refer to table below for selection of applicable auto switch. Auto switch is shipped not assembled with the cylinder. Standard grease (for non-food) Grease for food Note) Select grease for food for use in a water dispersion environment or when washing a product with water. (Water resistance is insufficient with standard grease.) Note) External seal material: Rod scraper, tube gasket,...

 Open the catalog to page 4
HY-5

Hygienic Design Cylinder Round Type Bore size (mm) Action Double acting, Single rod Minimum operating pressure Maximum operating pressure Proof pressure 1.5 MPa Without auto switch 0 to 70°C Ambient and operating fluid temperature With auto switch 0 to 60°C Not required 50 to 500 mm/s (With pressure at 1.0 MPa) Note) Piston speed Cushion Stroke length tolerance Piston rod material Stainless steel 304 / Hard chrome plated Note) Use a cylinder below the allowable kinetic energy. Refer to page 3 for the allowable kinetic energy. Standard Stroke Bore size (mm) ∗ Intermediate strokes of 1 mm each...

 Open the catalog to page 5
HY-6

Series HYB Allowable Kinetic Energy Maximum drive speed (V mm/s) Stroke (mm) • A case where the center of gravity of the load rests 50 mm from the rod end.

 Open the catalog to page 6
HY-7

Hygienic Design Cylinder Round Type

 Open the catalog to page 7
HY-8

Hygienic Design Cylinder Basic Type Without auto switch With auto switch R 50 F M R 50 F M F6B Number of auto switches With auto switch (Built-in magnet and switch rail) Auto switch Port thread type Nil TN TF Refer to table below for selection of applicable auto switch. Auto switch is shipped not assembled with the cylinder. Without auto switch (Built-in magnet and switch rail) Female thread Male thread Note) External seal material: Rod scraper, tube gasket, and rod seal are made from FKM. Cylinder stroke < Mounting bracket > Foot, flange, single clevis, double clevis, and clevis pin < Option...

 Open the catalog to page 8
HY-9

Hygienic Design Cylinder Basic Type Specifications Bore size (mm) Action Fluid Minimum operating pressure Maximum operating pressure Proof pressure Ambient and operating fluid temperature Double acting, Single rod Air 0.2 MPa 0.15 MPa 1.0 MPa 1.5 MPa Without auto switch 0 to 70°C With auto switch 0 to 60°C Not required 50 to 500 mm/s (With pressure at 1.0 MPa) Note) Rubber bumper +1.4 0 mm Stainless steel 304 / Hard chrome plated Lubrication Piston speed Cushion Stroke length tolerance Piston rod material Note) Use a cylinder below the allowable kinetic energy. Refer to page 7 for the allowable...

 Open the catalog to page 9
HY-10

Series HYQ Allowable Load at Rod End Allowable Kinetic Energy (Supply pressure: at P = 0.5 MPa) Maximum drive speed (V mm/s) Stroke (mm) • A case where the center of gravity of the load rests 50 mm from the rod end.

 Open the catalog to page 10
HY-11

Hygienic Design Cylinder Basic Type Construction: ø20, ø25 Basic type Built-in magnet Aluminum alloy Anodic oxide film Head cover Aluminum alloy Anodic oxide film Cylinder tube Aluminum alloy Anodic oxide film Aluminum alloy Stainless steel Hard chromium plated Bushing retainer Aluminum alloy Hexagon socket head cap screw Stainless steel Piston seal Tube gasket Stainless steel (Only built-in magnet) Magnet holder Aluminum alloy (Only built-in magnet) Chromated Switch rail base Stainless steel (Only built-in magnet) Hexagon bolt Stainless steel (Only built-in magnet) Switch rail Stainless steel...

 Open the catalog to page 11
HY-12

Series HYQ Construction: ø32 to ø63 Basic type Built-in magnet Aluminum alloy Anodic oxide film Magnet holder Aluminum alloy (Only built-in magnet) Chromated Head cover Aluminum alloy Anodic oxide film Switch rail base Stainless steel (Only built-in magnet) Cylinder tube Aluminum alloy Anodic oxide film Hexagon bolt Stainless steel (Only built-in magnet) Aluminum alloy Switch rail Stainless steel (Only built-in magnet) Stainless steel Hard chromium plated Bushing retainer Aluminum alloy Hexagon socket head cap screw Stainless steel Piston seal (Only ø63 is common to the bumper A.) Tube gasket...

 Open the catalog to page 12
HY-13

Hygienic Design Cylinder Basic Type Dimensions Without auto switch: HYQB20, 25 Q H thread effective depth C Rod end male thread Width across flats KA Width across flats B1 Rod End Male Thread Bore size Bore size Stroke range 50 or less 50 or less Note 1) Refer to page 32 for details about the rod end nut, mounting bracket and accessory bracket. Note 2) When the unit is installed, ensure that dirt does not collect in the rod end (threaded portion).

 Open the catalog to page 13
HY-14

Series HYQ Dimensions With auto switch: HYDQB20, 25 Q H thread effective depth C [Width across flats 3] Rod end male thread Width across flats KA Width across flats B1 Rod End Male Thread Bore size Bore size Stroke range 50 or less 50 or less Note 1) The [ ] value denotes dimensions with the auto switch D-F6 mounted, which is dedicated to the Hygienic Design Cylinder. Note 2) Refer to page 32 for details about the rod end nut, mounting bracket and accessory bracket. Note 3) When the unit is installed, ensure that dirt does not collect in the rod end (threaded portion).

 Open the catalog to page 14

All SMC catalogs and technical brochures

  1. Serie HRR

    64  Pages

  2. Série VP/VG

    33  Pages

  3. Série XL

    27  Pages

  4. Série JXC5H/6H

    36  Pages

  5. JMB series

    13  Pages

  6. JCM series

    21  Pages

  7. PF3A7*H

    40  Pages

  8. PF3W

    34  Pages

  9. Water Treatment

    16  Pages

  10. Vacuum Pad

    16  Pages

  11. Rotary Actuator

    40  Pages

  12. Compact Slide

    24  Pages

  13. Air Cylinder

    124  Pages

  14. JMGP series

    16  Pages

  15. ISO Cylinder

    32  Pages

  16. IZD10

    20  Pages

  17. IZH10

    8  Pages

  18. Check Valves

    4  Pages

  19. Series ZL

    20  Pages

  20. Series CM2

    92  Pages

  21. Series IDGA/IDG

    56  Pages

  22. IDH-A

    12  Pages

  23. CP96-C96-B

    74  Pages

  24. CVQ

    24  Pages

  25. VNA

    10  Pages

  26. Series MXY

    28  Pages

  27. Series MXP

    39  Pages

  28. Air Slide Table

    132  Pages

  29. S0700

    112  Pages

  30. SYJ

    96  Pages

  31. SY - NEW

    164  Pages

  32. VF

    60  Pages

  33. C(D)55 series

    24  Pages

  34. C(D)Q2 series

    216  Pages

  35. MGP series

    36  Pages

  36. 11-LEFS series

    19  Pages

  37. LECS series

    16  Pages

  38. LECPA series

    4  Pages

  39. KQ series

    80  Pages

  40. IDF series

    16  Pages

  41. ZP series

    69  Pages

  42. MHF series

    32  Pages

  43. MHZ series

    68  Pages

  44. CRB series

    44  Pages

  45. MGJ series

    7  Pages

  46. AC series

    98  Pages

  47. VH series

    14  Pages

  48. LVA series

    43  Pages

  49. VDW series

    28  Pages

  50. LVM series

    28  Pages

  51. VX2 series

    32  Pages

  52. MXH series

    32  Pages

  53. MXF series

    12  Pages

  54. CXW series

    48  Pages

  55. CXS series

    76  Pages

  56. CQS series

    40  Pages

  57. CQM series

    28  Pages

  58. CLQ series

    36  Pages

Archived catalogs

  1. KR

    7  Pages

  2. KF

    16  Pages

  3. AFF

    80  Pages

  4. HAA

    3  Pages

  5. ZFA

    14  Pages

  6. ZA

    13  Pages

  7. D

    117  Pages

  8. RB

    23  Pages

  9. cep

    44  Pages

  10. rsq

    30  Pages

  11. CLK

    51  Pages

  12. MK

    20  Pages

  13. CLJ

    65  Pages

  14. ARG

    48  Pages

  15. VXA

    17  Pages

  16. MXU

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.