Fan Type Ionizer RoHS Thinnest and Fastest Thickness Rapid static neutralisation Slim design Model Thickness (Depth) Extensive rapid static neutralisation [mm] Offset voltage (Ion balance) Installation distance ∗ When neutralising static electricity from 1000 V to 100 V at a distance of 300 mm from the workpiece (front surface). When air flow of IZF31 is maximum.
Open the catalog to page 1˾ Extensive Rapid Static Neutralisation Extensive static neutralisation ̈For the IZF21. For details about the IZF31, refer to page 8. ̈Refer to page 4 for flow rate adjustment and the description below for angle adjustment of the adjustable louver. At maximum flow rate 300 mm 6s 8s 4s At maximum flow rate, with adjustable louver/largest angle 300 mm At maximum flow rate, with adjustable louver/smallest angle 300 mm Extensive static neutralisation area can be covered with adjustable louver. Angle adjustment trimmer for adjustable louver Adjustable in 5-stages from wide to narrow angle 90-degree...
Open the catalog to page 2Rapid static neutralisation Installation distance and discharge time (Discharge time from 1000 V to 100 V) 20 ˾ Stable Static Neutralisation Performance, Easier Maintenance The emitters life is almost doubled with averaging function. + Polarity exchanged The life of the emitters is almost doubled by switching the polarity of the applied high voltage every time the power is supplied hence averaging the wear level of the emitters. Built-in sensor constantly monitors offset voltage. Automatic balance adjustment function achieves stable offset voltage and reduces adjustment time. Prevents reduction...
Open the catalog to page 3˾ Stable Static Neutralisation Performance, Easier Maintenance Emitter contamination can be reduced by automatic cleaning function. Cleaning arms are installed inside. Emitter cleaning is started by external input or operation button. The emitter points are cleaned with a brush by the motor driven rotating cleaning arms, which reduces the emitters' contamination. Cleaning brush Operation button Automatic cleaning unit Contamination of the emitters can be detected. Emitter contamination level is constantly monitored. When maintenance is required, the user is alerted by a signal output and the...
Open the catalog to page 4Fan Type Ionizer series IZF Flow Rate Adjustment Function Flow rate is adjustable in 10 steps using the flow rate adjustment dial. The flow rate adjustment dial is removable to prevent unexpected changes of adjustment. Flow Rate Adjustment Range Prevents ingress of lint and foreign matter to the motor and possibility of short-circuit between emitters!
Open the catalog to page 5Application Examples Static neutralisation on a conveyor Neutralising static electricity on PET bottles Neutralising static electricity from films Static neutralisation in a narrow space Trip-resistance during conveying/Prevents adhesion of dust. Prevents winding failure./Prevents adhesion of dust. Neutralising static electricity on molded goods Neutralising static electricity on film molded goods Static neutralisation on packaging materials made from polystyrene foam. Improves detachability of molded goods from a die. Sticking and scattering prevention on a conveyor Darkening due to dust adhesion...
Open the catalog to page 6• Fan Type Ionizer Series IZF21/31 Technical Data/ Static Neutralisation Performance Fan Type Ionizer Series IZF10 Technical Data/ Static Neutralisation Performance
Open the catalog to page 7Technical Data Static Neutralisation Performance Note) Static neutralisation performance is based on data using charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the EN 613405-1:2007 standars. Use only as a guideline for model selection because the value varies depending on the material and/or size of objects. q Installation Distance and Discharge Time (Discharge time from 1000 V to 100 V) 15 Air flow level: 1 10 Air flow level: 10 5 0 IZF31-S (With automatic cleaning unit) IZF21-S (With automatic cleaning unit) 15 Air flow level: 1 10 Air flow level: 10 5 0 15 Air flow level:...
Open the catalog to page 8Technical Data Series IZF21/31 Static Neutralisation Performance Note) Static neutralisation performance is based on data using charged plate (size: 150 mm x 150 mm capacitance: 20 pF) as defined in the EN 61340-5-1:2007 standars. Use only as a guideline for model selection because the value varies depending on the material and/or size of objects ©Static Neutralisation Range
Open the catalog to page 9Fan Type Ionizer Series IZF21/31 ∗ Filter + Filter holder Automatic cleaning unit, Louver None With automatic cleaning unit With adjustable louver With automatic cleaning unit + adjustable louver Power supply cable, AC adapter — Z R N With power supply cable (3 m) With power supply cable (10 m) With AC adapter (without AC cable) None None With filter∗
Open the catalog to page 10Emitter cartridge Technical Data Accessories (for Individual Parts) For IZF21 For IZF31 ∗ 4 retaining bolts are included. Power supply cable IZS41 CP Automatic cleaning unit Power supply cable — Z Power supply cable (3 m) Power supply cable (10 m) Total length: 1 m Total length: 2 m Power supply cable length Air suction side filter ∗ Available in 1 m increments from 1 m to 20 m. Use standard power supply cables for 3 m and 10 m lengths. Air suction side filter Filter holder Filter Filter + Filter holder Cleaning arm (for automatic cleaning unit) AC adapter (without AC cable) Adjustable louver Accessories...
Open the catalog to page 11Maximum air flow Applied voltage Ion generation method Method of applying voltage Offset voltage (Ion balance) Note) Power supply voltage Current consumption Input signal Output signal Ionizer stop signal Cleaning input signal Maintenance signal Error signal 4400 l/min ±5 kV Corona discharge type DC type ±5 V 24 VDC ±10 % Connect with +24 V Connect with 0 V Connect with 0 V Voltage range: 19 VDC to Voltage range: 5 VDC or less Voltage range: 5 VDC or less power supply voltage Current consumption: 5 mA or less Current consumption: 5 mA or less Current consumption: 5 mA or less Maximum load current:...
Open the catalog to page 12Error signal Turns OFF if power supply failure, incorrect high voltage, fan motor failure, CPU failure, excess OUT current on the output circuit, emitter cartridge mounting failure, or automatic cleaning failure (B contact) (for product with automatic cleaning function) is detected. (ON when there is no problem) — — Pin no. Cable colour Signal name Signal direction Description A1 Brown +24 VDC IN B1 Connect the power supply to operate the ionizer. A2 Blue 0V IN B2 A3 Green F. G. — Ground terminal with 100 Ω or less to use it as a reference electric potential for ionizer. Signal input to turn...
Open the catalog to page 136 Pages
64 Pages
33 Pages
27 Pages
45 Pages
36 Pages
15 Pages
13 Pages
21 Pages
40 Pages
34 Pages
36 Pages
16 Pages
4 Pages
26 Pages
16 Pages
224 Pages
16 Pages
272 Pages
40 Pages
18 Pages
24 Pages
124 Pages
180 Pages
16 Pages
32 Pages
20 Pages
8 Pages
4 Pages
16 Pages
74 Pages
20 Pages
20 Pages
92 Pages
56 Pages
14 Pages
12 Pages
74 Pages
24 Pages
52 Pages
10 Pages
28 Pages
39 Pages
132 Pages
138 Pages
112 Pages
96 Pages
164 Pages
60 Pages
24 Pages
216 Pages
36 Pages
19 Pages
16 Pages
4 Pages
80 Pages
16 Pages
69 Pages
32 Pages
68 Pages
44 Pages
7 Pages
98 Pages
14 Pages
43 Pages
28 Pages
28 Pages
32 Pages
32 Pages
12 Pages
48 Pages
76 Pages
40 Pages
28 Pages
36 Pages