cad

ZB
1 /24Pages

ZB

ZB
1 /24Pages

Catalog excerpts

ZB-1

Compact Vacuum Unit Ejector/Vacuum Pump System Response time _ Vacuum response time: LÖ ms Comparison with other SMC products) «Conditions: Nozzle size 0O.6, when the pressure reaches -60 kPa. vacuum piping size 04/o2.5 x 50 mm Vacuum breaking time: Ü4J ÎM * Conditions: Needle flow rate set to 10 LVmln, when the pressure reaches atmospheric pressure, with supply pressure 0.5 MPa, vacuum piping size 04/o2.5 x 50 mm * Compared with existing model Supply valve, release valve, vacuum break flow adjustment needle, suction filter, and silencer With vacuum pressure switch Vacuum break flow adjustment needle sensor (source of copy) can be copied to the slave sensors. Reduction in setting work Prevention of mistakes in setting Nominal filtration rating: 30 urn Slave side -» 1 unit

 Open the catalog to page 1
ZB-2

ZB-A.qxd 10.9.7 11:58 AM Page 2 Series ZB Unit with release pressure supply port can be selected. Air pressure and release pressure can be adjusted separately. Release pressure can be adjusted to suit the workpiece. Supply valve Port open to atmosphere Release valve Port open to atmosphere Supply valve Air pressure SUP port (PV) Release valve Release pressure SUP port (PD) Release pressure SUP port V Air/Vacuum pressure SUP port Release response time is shortened by 25% by the port open to atmosphere. Vacuum (V) port pressure Having the R port of the supply valve open to atmosphere allows instant...

 Open the catalog to page 2
ZB-3

Easy maintenance Simple installation and removal without the use of screws filter element sound absorbing material Fine adjustment of the vacuum break It can be adjusted from 1 to 14.5 L/min (ANR). * With the supply pressure 0.5 MPa Needle opening [rotations] (Filter element) Filter case Unit either with vacuum pressure*switch latching type valve Latching type can be selected for the supply valve. (Nozzle sizes: Reduces power consumption by reducing energization time when generating vacuum, and prevents workpieces being dropped if there is an instantaneous power Construction which reduces discharge...

 Open the catalog to page 3
ZB-4

Compact Vacuum Unit How to Order Single Unit Vacuum Pump System Q Nominal Nozzle Size Note 1) Vacuum pump system only QExhaust Type pump system Port exhaust Note 2) Names of the ports and functions are as PV: Air pressure SUP port (Ejector) Vacuum pressure SUP port (Vacuum pump system) PD: Release pressure SUP port (For the unit with PD port, select the model with a release valve for O ) Specify the port specification of the body for manifold with the manifold model number. Q Combination of Supply Valve and Release Valve * Vacuum break by port open to atmosphere Note 3) Refer to SUfídU on page...

 Open the catalog to page 4
ZB-5

Compact Vacuum Unit Series ¿D Q Pressure Sensor/Vacuum Pressure Switch Specifications Without pressure sensor/vacuum pressure switch Pressure sensor Vacuum pressure Output: 1 to 5 V, accuracy: ±2% F.S. or less Note7> Output: 1 to 5 V, accuracy: ±2% F.S. or less With unit switching function Note8> With unit switching function [Initial value psi] With unit switching function Note8> With unit switching function [Initial value psi] With unit switching function Note8> With unit switching function [Initial value psi] With unit switching function Note8> With unit switching function [Initial value psi]...

 Open the catalog to page 5
ZB-6

0 Pressure Sensor/Vacuum Pressure Switch Mountable Note> Sensor/switch non-mountable base Sensor/switch mountable base Note) Select "S" when the model with either the pressure sensor or the vacuum pressure switch is selected in ©for the single unit. (Refer Q Common Supply (PV) Port Size Q Common Release Pressure (PD) Port Size Note> Note) Refer to ©on page 1 for the combinations of supply valve and release valve selectable. Common supply : Prepare a part to plug the unused port if the unit is used with an air supply on one side. Example) For M5 x 0.8: M-5P Select the body type 1 or 2 referring...

 Open the catalog to page 6
ZB-7

Compact Vacuum Unit Series ¿D General Specifications Supply Valve/Release Valve Common Specifications Note) Push-locking type only for the latching type Note 1) 10 to 500 Hz for 2 hours in each direction of X, Y and Z (During de-energizing) Note 2) 3 times in each direction of X, Y and Z (During de-energizing) Supply Valve/Release Valve Specifications Note 1) Latching type is applicable only to the ejector nozzle sizes 00.3 and 00.4 Note 2) Inrush: 3.1 W (10 ms after energized); Holding: 0.7 W Note 3) M-type can also be selected when the ejector or the pump system is selected without pressure...

 Open the catalog to page 7
ZB-8

Ejector Exhaust Characteristics/Flow-rate Characteristics Nozzle Size o0.3 Supply Valve, Large Flow Type (N.C.)/ZB03DD- j1 Exhaust Characteristics Flow-rate Characteristics Nozzle Size oQ.4 Supply Valve, Large Flow Type (N.C.)/ZB04DD- j1 Exhaust Characteristics Flow-rate Characteristics Nozzle Size oQ.5 Supply Valve, Large Flow Type (N.C.)/ZB05DD- j1 Exhaust Characteristics Flow-rate Characteristics Nozzle Size o0.6 Supply Valve, Large Flow Type (N.C.)/ZB06DD Exhaust Characteristics Flow-rate Characteristics

 Open the catalog to page 8
ZB-9

Compact Vacuum Unit Series ¿D Nozzle Size o0.3 Supply Valve, Latching Type/ZB03DD-C,2 Exhaust Characteristics Flow-rate Characteristics Nozzle Size o0.4 Supply Valve, Latching Type/ZB04DD-C,2 Exhaust Characteristics Flow-rate Characteristics Vacuum Pump System Flow-rate Characteristics/ZBOO Release Flow-rate Characteristics (Ejector/Pump System) The graph shows the suction flow-rate characteristics of the vacuum pump system at different vacuum pressures. The graph shows the flow-rate characteristics with various supply pressures when the vacuum break flow adjustment needle is opened from the...

 Open the catalog to page 9
ZB-10

Pressure Sensor/Vacuum Pressure Switch Pressure SenSOl7ZB1 -PSD-A (Refer to the PSE series in Best Pneumatics No. 6 and Operation Manual for details.) Vacuum Pressure Sw¡tch/ZB1 -ZSDDDD-A (Refer to the individual catalog ZSE/ISE10 series and Operation Manual for details.) Note 1) If the applied voltage fluctuates around the set value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur. Note 2) Refer to "General Specifications" on page 4 for the specifications not shown In the table. Description (Vacuum Pressure Switch)_ Internal Circuit and...

 Open the catalog to page 10

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36  Pages

  2. IDF series

    12  Pages

  3. MHL2 Series

    24  Pages

  4. JCM Serie

    18  Pages

  5. EX245 Series

    12  Pages

  6. SY

    268  Pages

  7. es70-44c-vx2

    52  Pages

  8. es50-37-kq2

    124  Pages

  9. ex-pcw

    23  Pages

  10. es20-230b-crb2

    59  Pages

  11. VH

    9  Pages

  12. CUJ

    41  Pages

  13. AL

    3  Pages

  14. kj mm

    9  Pages

  15. AQ

    4  Pages

  16. Series MB

    24  Pages

  17. Series LES

    23  Pages

  18. Series LEFB

    16  Pages

  19. Series PF3W

    28  Pages

  20. Series LEY

    7  Pages

  21. Series VHS

    12  Pages

  22. Series CY1S

    28  Pages

  23. AS series

    2  Pages

  24. corporate guide

    13  Pages

  25. ZP

    69  Pages

  26. ZFA

    14  Pages

  27. ZA

    13  Pages

  28. MHF

    32  Pages

  29. MHZ

    68  Pages

  30. CRB

    44  Pages

  31. D

    117  Pages

  32. RB

    23  Pages

  33. CEP

    44  Pages

  34. RSK

    30  Pages

  35. CLK

    51  Pages

  36. MK

    20  Pages

  37. GLJ

    65  Pages

  38. MGJ

    7  Pages

  39. Mx

    36  Pages

  40. MXH

    18  Pages

  41. My3

    56  Pages

  42. my1b

    20  Pages

  43. CC

    15  Pages

  44. J

    14  Pages

  45. CQ2

    51  Pages

  46. VFN

    6  Pages

  47. SY3000

    246  Pages

  48. SJ3A6

    18  Pages

  49. 1301/IW

    14  Pages

  50. CHQ/CHDQ

    19  Pages

  51. AC

    95  Pages

  52. HAW

    4  Pages

  53. HAA

    3  Pages

  54. CRB2

    35  Pages

Archived catalogs

  1. CJ1

    5  Pages

  2. SYJ

    62  Pages

  3. SJ

    78  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.