cad

Series IZS40/41/42
32Pages

{{requestButtons}}

Catalog excerpts

Series IZS40/41/42 - 1

Ionizer New RoHS Potential amplitude: 25 V or less Rapid elimination of static electricity: Fastest time: 0.1 seconds Note 1) Dual AC type Note 2) Series IZS42 Potential amplitude is reduced with Dual AC type. Feedback sensor type Series IZS41 Rapid elimination of static electricity by a feedback sensor Standard type Series IZS40 Simple operation: Can be controlled by powering the ionizer ON. Note 1) IZS42, Installation height: 300 mm Note 2) Conditions/With feedback sensor Charged voltage: 1000 V 100 V Discharged object: Charged plate (150 mm x 150 mm, capacitance 20 pF) Installation distance: 200 mm (Tungsten electrode needle with air purge) Series IZS40/41/42 CAT.ES100-97A

Open the catalog to page 1
Series IZS40/41/42 - 2

Dual AC type Series IZS42 (Potential amplitude reduction specification) Potential amplitude: 25 V or less 80% reduction compared to the conventional model (Compared to the IZS31 series at the installation height of 300 mm) Potential amplitude is reduced with SMC independent Dual AC type sensor. Static electricity elimination may be achieved without causing damage to a device which is sensitive to electrostatic discharge (ESD). Potential amplitude applied to the applicable workpiece is reduced even if it the workpiece is mounted within close proximity of the ionizer. Independent Dual AC type...

Open the catalog to page 2
Series IZS40/41/42 - 3

_ . f_0_. (High speed static electricity Feedback SenSOr type Series /Zo4 7 elimination specification)^ Note) An ion balance sensor 'Rapid elimination of static electricity by a feedback sensor The speed of static electricity elimination has been increased by reading the workpiece's electrostatic potential by the feedback sensor (option) and continuously emitting ions with a reverse polarity. With sensor Without sensor Without sensor With sensor Feedback sensor Detects the polarity of a discharged object Supply pressure: 0.1 MPa Operation frequency: 30 Hz Electrode cartridge with rapid...

Open the catalog to page 3
Series IZS40/41/42 - 4

Reduction of adjustment and maintenance labor by auto balance sensor 'S? « Built-in type (Standard) The sensor is installed within the ionizer body and may be mounted anywhere. Monitoring the amount of ion emitted from an ionizer, the autobalance sensor maintains the initial ion balance by adjusting the +/- ion supply rate. Monitoring +/- return current rHigh accuracy type (Option) • The ion balance near the workpiece is accurately adjusted. • The object is not affected by the height of installation or any disturbance interference Auto balance sensor Low maintenance electrode cartridges are...

Open the catalog to page 4
Series IZS40/41/42 - 5

Refer to Features 5 for Models and Functions. Setting ionizer with remote controller “Ion balance adjustment at external signal input” or “Ion balance adjustment at any time” can be selectable. The auto balance sensor may be connected only when adjusting the ion balance. Automatic ion balancing by means of signal input Ion balance value (V) IZS 42 Total number of ionizers that may be connected IZS41: Max. 8 units. IZS42: Max. 5 units. 25 0 May be used to adjust and set several ionizers remotely. Can recognize and control up to 16 ionizers through address setting. Frequency setting Ion...

Open the catalog to page 5
Series IZS40/41/42 - 6

Ionizer Series IZS40/41/42 Models and Functions IZS42 IZS41 IZS40 Series Method of applying voltage Sensor (Auto balance) Dual AC AC, Sensing AC, DC AC, DC Built-in type (Standard) — High accuracy type (Option) — Feedback sensor (Option) — I/O — Transition wiring may be used. Note 1) — Electrode needle contamination detector — Incorrect high voltage ion discharge detection Low maintenance electrode Energy saving type de-ionizing Cartridge High speed de-ionizing With one-touch fitting (ø6, ø8, ø10) Bracket mount Non-standard bar length (Made to Order) Note 1) Order transition wiring...

Open the catalog to page 6
Series IZS40/41/42 - 7

Application Examples Eliminating static electricity from films Eliminating static electricity on film molded goods · Prevents adhesion of dust. · Prevents winding failure due to wrinkles etc. · Prevents attaching to conveyer. · Prevents dispersion of finished goods. Eliminating static electricity during wafer transfer Eliminating static electricity from packing films · Prevents breakage due to discharge between wafers and hands. · Prevents the filled substance from adhering to the packing film. · Reduces packing mistakes. Eliminating static electricity from lens Eliminating static...

Open the catalog to page 7
Series IZS40/41/42 - 8

Series IZS40/41/42 Technical Data Static Electricity Elimination Characteristics Note) Static electricity elimination features are based on the data using the charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S. ANSI standards (ANSI/ESD, STM3.1-2006). Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject. q Installation Distance and De-ionization Time (Electricity Elimination from 1000 V to 100 V) IZS40, 41 Static electricity elimination time (sec) 1) Without air purge 20 18 16 14 12...

Open the catalog to page 8
Series IZS40/41/42 - 9

Technical Data Series IZS40/41/42 2) With high speed de-ionizing cartridge, With air purge- Supply pressure: 0.1 MPa (8.6 L/min [ANR] per cartridge) 3) With energy saving type de-ionizing cartridge, With air purge- Supply pressure: 0.1 MPa (4.3 L/min [ANR] per cartridge) Supply pressure: 0.3 MPa (17.6 L/min [ANR] per cartridge) Supply pressure: 0.3 MPa (8.6 L/min [ANR] per cartridge) Supply pressure: 0.5 MPa (26.4 L/min [ANR] per cartridge) Supply pressure: 0.5 MPa (13.3 L/min [ANR] per cartridge)

Open the catalog to page 9
Series IZS40/41/42 - 10

Series IZS40/41/42 Static Electricity Elimination Characteristics Note) Static electricity elimination features are based on the data using the charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S. ANSI standards (ANSI/ESD, STM3.1-2006). Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject. w Static Electricity Elimination Range IZS40, 41 Frequency: 30 Hz 250 200 150 100 0 50 50 0 50 100 150 200 250 Installation distance in depth from ionizer to workpiece - Charged object location (mm)...

Open the catalog to page 10

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36 Pages

  2. IDF series

    12 Pages

  3. MHL2 Series

    24 Pages

  4. JCM Serie

    18 Pages

  5. EX245 Series

    12 Pages

  6. SY

    268 Pages

  7. es70-44c-vx2

    52 Pages

  8. es50-37-kq2

    124 Pages

  9. ex-pcw

    23 Pages

  10. es20-230b-crb2

    59 Pages

  11. VH

    9 Pages

  12. CUJ

    41 Pages

  13. AL

    3 Pages

  14. kj mm

    9 Pages

  15. AQ

    4 Pages

  16. Series MB

    24 Pages

  17. Series LES

    23 Pages

  18. Series LEFB

    16 Pages

  19. Series PF3W

    28 Pages

  20. Series LEY

    7 Pages

  21. Series VHS

    12 Pages

  22. Series CY1S

    28 Pages

  23. AS series

    2 Pages

  24. ZP

    69 Pages

  25. ZFA

    14 Pages

  26. ZA

    13 Pages

  27. MHF

    32 Pages

  28. MHZ

    68 Pages

  29. CRB

    44 Pages

  30. D

    117 Pages

  31. RB

    23 Pages

  32. CEP

    44 Pages

  33. RSK

    30 Pages

  34. CLK

    51 Pages

  35. MK

    20 Pages

  36. GLJ

    65 Pages

  37. MGJ

    7 Pages

  38. Mx

    36 Pages

  39. MXH

    18 Pages

  40. My3

    56 Pages

  41. my1b

    20 Pages

  42. CC

    15 Pages

  43. J

    14 Pages

  44. CQ2

    51 Pages

  45. VFN

    6 Pages

  46. SY3000

    246 Pages

  47. SJ3A6

    18 Pages

  48. 1301/IW

    14 Pages

  49. CHQ/CHDQ

    19 Pages

  50. AC

    95 Pages

  51. HAW

    4 Pages

  52. HAA

    3 Pages

  53. ZB

    24 Pages

  54. CRB2

    35 Pages

  55. CJ1

    5 Pages

  56. SYJ

    62 Pages

  57. SJ

    78 Pages

Archived catalogs