General-purpose connectors Push Pull connectors One-touch removal/mounting requires fewer work-hours *1 Abbreviation of the Automation Initiative of German (Deutschland) Automobile Manufacturers • PROFIenergy • Shared Device Power supply connector: 7/8 inch Compatible with new functions of • NET Load Class H • MRPD Push Pull connectors Digital input module Digital output module FW (firmware) update function Simultaneous writing is possible from network connection. Web server function Status check and valve ON/OFF are possible on the web browser. Existing model Compact, Lightweight Height: 40 mm reduction Weight: 53.5% reduction (@w465 g b Existing model: 1000 g
Open the catalog to page 1Fieldbus System (For Input/Output) EX245 Series Compatible with PROFIenergy, the energy-saving function Generally, the switching off of the facilities in factories consumes a lot of time to restart them. PROFIenergy enables PROFINET communication to continue while saving energy by minimizing the time for restarting. When the commands for PROFIenergy energy-saving mode are sent from the I/O controller (PLC) to the I/O device (SI unit), the information of time for pausing is also sent (such as lunch breaks, nighttime, weekends, holidays). The SMC SI unit does not require time for restarting. However,...
Open the catalog to page 2Fieldbus System (For Input/Output) EX245 Series MRP/MRPD function MRP (Media Redundancy Protocol) function Even if a communication cable is disconnected or damaged at any location, communication can be continued. Furthermore, it is possible to identify the disconnection point, and the network disconnection time can be made within 200 ms. Normal flow of data Redundancy manager Data flow when the communication cable is disconnected Redundancy manager Client w Disconnected Client e * o use the MRP function, the PLC should be T able to support the MRP function. MRPD (Media Redundancy for Planned...
Open the catalog to page 3Fieldbus System (For Input/Output) EX245 Series Fast Start Up function For the Fast Start Up function, time from power ON to communication connection Save time when connecting and improve productivity In the case of a tool changer, it takes about 10 seconds for communication to be connected in some products after the power to the device installed on the tool is turned ON. For products which support the Fast Start Up function, communication can be operational even faster. * o use the Fast Start Up function, the PLC should be T able to support the Fast Start Up function. Fiber-optic cable maintenance...
Open the catalog to page 4CONTENTS Fieldbus System (For Input/Output) EX245 Series
Open the catalog to page 5Fieldbus System For Input/Output Connector type Digital Input Module EX245-DX1 EX245 -EA2- Digital input module specification Digital input (16 inputs) Digital Output Module EX245-DY1 Digital output module specification Digital output (8 outputs) Refer to the Web Catalog for manifold valve part numbers. Bracket 3 to 5 correspond to the mounting hole pitch of each manifold valve.
Open the catalog to page 6Fieldbus System For Input/Output EX24o Series Common Specifications for All Units/Modules *1 The configuration file can be downloaded from the SMC website, https://www.smcworld.com Digital Input Module *1 An M12 (4-pin) connector can also be connected. Digital Output Module *1 An M12 (4-pin) connector can also be connected.
Open the catalog to page 7EX245 Series Dimensions/Parts Description SI Unit EX245-SPN1A/2A PROFINET connection port M12 connector (4-pin, Socket, D-coded) Power supply connector 7/8 inch connector (5-pin, Socket) PROFINET connection port Push Pull connector EX245-SPN1A: SCRJ EX245-SPN2A: RJ45 Product label Power supply connector Push Pull connector (24 V) Digital Input Module EX245-DX1 Power supply connector 7/8 inch connector (5-pin, Plug) Digital Output Module EX245-DY1 Input connector 8 x M12 connector (5-pin, Socket) Output connector 4 x M12 connector (5-pin, Socket) LED indicator (ON/OFF of the output device) LED...
Open the catalog to page 8EX245 Series Assembly Examples Manifold valve SI unit Digital input module Digital output module End plate Refer to the Web Catalog for order numbers. EX245-SPN1A EX245-DX1 EX245-DY1 EX245-EA2-3 The modules and manifold valve are not assembled at the time of shipment. After assembling the SI unit and manifold valve, assemble the modules. Width across flats: 2.5 mm∗1 Tightening torque JSY : 0.75 to 0.85 N·m SY : 0.75 to 0.85 N·m VQC : 0.5 to 0.7 N·m Manifold valve Manifold valve SI unit Digital input module Digital output module End plate (With bracket) *1 Tightening tool is not included....
Open the catalog to page 10t Communication cable/connector y Field-wireable communication connector u I/O cable with connector, I/O connector q Seal cap q Seal cap w Marker r 7/8 inch connector and related parts Be sure to mount a seal cap on any unused I/O connectors. Otherwise, the specified enclosure cannot be maintained. The signal name of I/O device and each module name can be entered and mounted on each module. For power supply connectors (10 pcs.) Seal cap for communication connector and power supply connector are included when EX245-SPN1A/2A is shipped (2 caps for each unit). r 7/8 Inch Connector and Related Parts...
Open the catalog to page 11t Communication Cable/Connector EX9-AC 005 EN-PSPS (With connector on both sides (Plug/Plug)) Terminal Core wire no. color Plug connector pin arrangement Metal part^^Shield Yellow White Orange Blue Metal parts Connections (Straight cable) Signal name TD+ RD+ TD-RD-Plug connector pin arrangement D-coded EN-PAPA (With angled connector on both sides (Plug/Plug)) Metal parts M12 SPEEDCON Plug connector pin arrangement D-coded sMetalparts Shield Metal parts Connections (Straight cable) Plug connector pin arrangement D-coded
Open the catalog to page 12Terminal Signal name no. Terminal Core wire no. color Plug connector pin arrangement D-coded Green Metal parts Connections (Straight cable) Plug connector pin arrangement 0 Field-wireable Communication Connector PCA-1446553 D-coded Applicable Cable * The table above shows the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.
Open the catalog to page 1399 Pages
117 Pages
36 Pages
12 Pages
24 Pages
18 Pages
12 Pages
19 Pages
63 Pages
79 Pages
268 Pages
2 Pages
2 Pages
5 Pages
6 Pages
5 Pages
3 Pages
52 Pages
124 Pages
23 Pages
29 Pages
12 Pages
11 Pages
32 Pages
59 Pages
10 Pages
42 Pages
41 Pages
62 Pages
111 Pages
59 Pages
127 Pages
9 Pages
41 Pages
3 Pages
9 Pages
4 Pages
2 Pages
24 Pages
23 Pages
16 Pages
28 Pages
56 Pages
7 Pages
32 Pages
7 Pages
12 Pages
28 Pages
4 Pages
12 Pages
60 Pages
2 Pages
2 Pages
13 Pages
69 Pages
14 Pages
13 Pages
32 Pages
68 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
36 Pages
18 Pages
56 Pages
20 Pages
15 Pages
14 Pages
51 Pages
84 Pages
6 Pages
246 Pages
18 Pages
14 Pages
19 Pages
95 Pages
4 Pages
3 Pages
24 Pages
35 Pages
5 Pages
62 Pages
78 Pages
60 Pages
62 Pages