cad

ex-pcw
1 /23Pages

ex-pcw

ex-pcw
1 /23Pages

Catalog excerpts

ex-pcw-1

Position Detection Switch Flow Sensor Pressure Control Pressure Sensor Simple parallel wiring type Ȝ Branch unit separates each manufacturer’s 32 point Input/Output (I/O) into 16 point common pin layout. Ȝ Conversion to a common pin layout, allows connection of the pin to SMC manifold solenoid valves and other manufacturers’ relay terminals without restriction. Ȝ Power can be supplied to the PLC I/O unit. Ȝ Compatible branch units are available for each PLC manufacturer’s I/O. Ȝ Without time delay unlike serial transmission. Ȝ Easy visual understanding at a glance, offering simple start-up, de-bug and trouble shooting maintenance. Length Measuring/ Counter Branch unit offers commonality Static Electricity Elimination Equipment Reduced-wiring Fieldbus System ed! y add ewl e is n nection n typ n e-co touch co labor. g One- es wirin c redu Improved wiring efficiency and ease of operation Alphabetical Index Ȝ Dedicated cable reduces wiring-equivalent to a serial transmission system. Ȝ One-touch type connector offers standardized wiring to prevent incorrect connection and vastly improved operational efficiency.

 Open the catalog to page 1
ex-pcw-2

A revolutionary new wiring system... Compatible PLC Manufacturers OMRON Corporation Mitsubishi Electric Corporation Sharp Corporation KEYENCE CORPORATION Direct connected branch unit Note) Applicable e-con type PLC manufacturers: OMRON Corporation, Mitsubishi Electric Corporation e-con 16 point branch unit (with cover) e-con 8 point unit (with cover) e-con 8 point unit (circuit board) 32 point unit with terminal block

 Open the catalog to page 2
ex-pcw-3

8 point unit with terminal block Alphabetical Index Length Measuring/ Counter Static Electricity Elimination Equipment Reduced-wiring Fieldbus System Position Detection Switch Flow Sensor Pressure Control Series PCW Pressure Sensor The PC wiring system simplifies wiring between a PLC and all types of connected equipment. PC Wiring System Branch unit

 Open the catalog to page 3
ex-pcw-4

Standardized pin layout Once 32 point terminal block unit or branch unit is replaced, no further wiring/design is necessary. Company A’s PLC I/O card Connector pin assignment (pin layout) Company B’s PLC I/O card Connector pin assignment (pin layout) General purpose terminal block unit Terminal block layout General purpose terminal block unit Terminal block layout + + + + - Poor performance in maintenance. Wiring must be redesigned again. PC wiring 32 point terminal block unit Terminal block layout Input device (sensor)/ output device (solenoid valve, etc.) to be connected. PC Wiring system brings...

 Open the catalog to page 4
ex-pcw-5

PCW-EC (e-con Type) Circuit board type With cover (DIN rail mount) Circuit board type Circuit board type With cover (DIN rail mount) With cover (DIN rail mount) Unit with e-con combines branch unit with 16 point unit. 16 point unit with e-con allows common models used for both I/O units. 8 point unit with e-con allows common models used for both I/O units. Can use two 8 point I/O units in a cascade connection. PC Wiring System /Series P. 594 Branch unit: PLC direct connected type Branch unit 8 point branch unit Directly mounted on PLC I/O card. Connected to PLC I/O card via connection cable....

 Open the catalog to page 5
ex-pcw-6

PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage Rated current 24 VDC Power supply line Communication line Insulation resistance Withstand voltage Impact resistance Screw tightening torque (Phillips head Terminal block screwdriver/flat head screwdriver) specifications Wire stripping length (recommended) Connecting wire size Input/output connector Ambient temperature e-con connector No need for special tools and wire stripping. Weight Model q Insert the electric cables into the cover. Option (e-con Connector) Model 1 pc. w Press with pliers. 10 seconds for 4 cables....

 Open the catalog to page 6
ex-pcw-7

Series PCW-EC 16 Point Input/Output Branch Unit Dimensions Flow Sensor Position Detection Switch With cover (DIN rail mount compatible) 45 28.3 Reduced-wiring Fieldbus System Models Input Note Circuit board type With cover (DIN rail mount compatible) Circuit board type With cover (DIN rail mount compatible) Length Measuring/ Counter ∗ Refer to pages 3 to 4 in CAT.02-20 about the circuit diagram. Alphabetical Index With cover (DIN rail mount compatible) Pressure Control Pressure Sensor 4-ø3.2 circuit board mounting hole Static Electricity Elimination Equipment Circuit board type Circuit board...

 Open the catalog to page 7
ex-pcw-8

Series PCW-EC 16 Point Input/Output Unit Models Circuit board type Circuit board type With cover (DIN rail mount compatible) ∗ Refer to page 5 in CAT.02-20 for the circuit diagram. Dimensions 4-ø3.2 circuit board mounting hole Circuit board type + With cover (DIN rail mount compatible) With cover (DIN rail mount compatible) DC24V MADE IN JAPAN

 Open the catalog to page 8
ex-pcw-9

Series PCW-EC 8 Point Input/Output Unit Models PCW-EC08Z00 PCW-EC08Z01 Circuit board type Pressure Sensor Circuit board type With cover (DIN rail mount compatible) ∗ Refer to page 6 in CAT.02-20 for the circuit diagram. Pressure Control 4-ø3.2 circuit board mounting hole Circuit board type Flow Sensor With cover (DIN rail mount compatible) Reduced-wiring Fieldbus System Position Detection Switch With cover (DIN rail mount compatible) Length Measuring/ Counter Static Electricity Elimination Equipment Alphabetical Index

 Open the catalog to page 9
ex-pcw-10

Series PCW Common Specifications Rated voltage Rated current 24 VDC Power supply line Communication line Insulation resistance Impact resistance Terminal block Withstand voltage Power terminal (Phillips screw driver/Flat head screw driver) I/O terminal (Phillips screw driver/ Flat head screw driver) Wire stripping Power terminal length (recommended) I/O terminal Screw tightening torque Connecting wire size Power terminal I/O terminal Cable Specifications PVC sheath Power lines With power lines Model Flat cable Without power lines Power lines Note) The flat ribbon cable without power lines are...

 Open the catalog to page 10
ex-pcw-11

Branch Unit: PLC Direct Connected Type Specifications Weight Ambient temperature Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Pressure Sensor Pressure Control Models Input Circuit diagram Page 9 in CAT.E02-20 Page 10 in CAT.E02-20 Two pieces are required for 64 points of input/output. Note 1) Combine one piece each of PCW-993106 and PCW-993108 (the PLC connection side connectors are reversed). Note 2) Combine one piece each of PCW-993107 and PCW-993109 (the PLC connection side connectors are...

 Open the catalog to page 11

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36  Pages

  2. IDF series

    12  Pages

  3. MHL2 Series

    24  Pages

  4. JCM Serie

    18  Pages

  5. EX245 Series

    12  Pages

  6. SY

    268  Pages

  7. es70-44c-vx2

    52  Pages

  8. es50-37-kq2

    124  Pages

  9. es20-230b-crb2

    59  Pages

  10. VH

    9  Pages

  11. CUJ

    41  Pages

  12. AL

    3  Pages

  13. kj mm

    9  Pages

  14. AQ

    4  Pages

  15. Series MB

    24  Pages

  16. Series LES

    23  Pages

  17. Series LEFB

    16  Pages

  18. Series PF3W

    28  Pages

  19. Series LEY

    7  Pages

  20. Series VHS

    12  Pages

  21. Series CY1S

    28  Pages

  22. AS series

    2  Pages

  23. corporate guide

    13  Pages

  24. ZP

    69  Pages

  25. ZFA

    14  Pages

  26. ZA

    13  Pages

  27. MHF

    32  Pages

  28. MHZ

    68  Pages

  29. CRB

    44  Pages

  30. D

    117  Pages

  31. RB

    23  Pages

  32. CEP

    44  Pages

  33. RSK

    30  Pages

  34. CLK

    51  Pages

  35. MK

    20  Pages

  36. GLJ

    65  Pages

  37. MGJ

    7  Pages

  38. Mx

    36  Pages

  39. MXH

    18  Pages

  40. My3

    56  Pages

  41. my1b

    20  Pages

  42. CC

    15  Pages

  43. J

    14  Pages

  44. CQ2

    51  Pages

  45. VFN

    6  Pages

  46. SY3000

    246  Pages

  47. SJ3A6

    18  Pages

  48. 1301/IW

    14  Pages

  49. CHQ/CHDQ

    19  Pages

  50. AC

    95  Pages

  51. HAW

    4  Pages

  52. HAA

    3  Pages

  53. ZB

    24  Pages

  54. CRB2

    35  Pages

Archived catalogs

  1. CJ1

    5  Pages

  2. SYJ

    62  Pages

  3. SJ

    78  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.