5 Port Solenoid Valve - 1

5 Port Solenoid Valve powe ced 5w 0.5 w 55 1. (Con 0 W) . al: 2 ion vent RoHS tion: p m onsu rc Redu New power [With uit] circ saving ard] [Stand With ght DC li Power consumption is reduced by power saving circuit. Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown below. Electrical power waveform with power saving circuit Series VF3000 Built-in full-wave rectifier (AC) Noise reduction Noise is considerably reduced by changing it to DC mode with a full-wave rectifier. Reduced apparent power Conventional: 5.6 VA 1.55 VA Built-in strainer in the pilot valve Unexpected troubles due to foreign matter can be prevented. Note) Be sure to mount an air filter on the inlet side. Applied voltage 24 V Rubber material: HNBR Ozone-resistant specification The pilot valve poppet is made of FKM. 0V Standard 1.55 W Energy saving 0.55 W With power saving circuit 0W 40 ms Strainer New Low wattage specification added VF1000/3000 Power consumption Series VF1000/3000/5000 0.35 W (Without light) 0.4 W (With light) CAT.ES11-99C

Open the catalog to page 1
5 Port Solenoid Valve - 2

Series VF1000/3000/5000 Model Selection by Operating Conditions q Single Unit Series Sonic conductance C [dm3/(s·bar)] VF1000 Type of actuation Port size Voltage Electrical entry Light/Surge voltage suppressor Manual override 2-position single VF1000 (B)2 0.76 4(A) (EB)3 1 5(EA) (P) VF3000 VF5000 Grommet M5 x 0.8 1/8 (A)4 2(B) (EA)5 1 3(EB) (P) L-type plug connector 2-position double VF1000 VF3000 (B)2 4(A) Non-locking push type Body ported (EB)3 1 5(EA) (P) 4.0 VF3000 VF5000 (A)4 2(B) 1/8 1/4 (EA)5 1 3(EB) (P) 3-position closed center (A)4 VF5000 DC 2(B) With surge voltage suppressor (EA)5...

Open the catalog to page 2
5 Port Solenoid Valve - 4

Cylinder Speed Chart © Please check the actual conditions with SMC Body Ported Model Selection Program. * With when using steel piping Base Mounted * With ^ when using steel piping

Open the catalog to page 4
5 Port Solenoid Valve - 5

Cylinder Speed Chart w Use as a guide for selection. Please check the actual conditions with SMC Model Selection Program. Conditions Body Ported Body ported Series CJ2 Series CM2 Series MB, CA2 Series CS1 Tubing x Length VF1120-01 T0604 x 1 m T0806 x 1 m — Speed controller AS3002F-06 AS3002F-08 — Tubing x Length VF3130-02 — AN101-01 Silencer Speed controller T1075 x 1 m AS3002F-06 — AS4002F-10 T0604 x 1 m — — AN110-01 Silencer Tubing x Length VF5120-03 T0604 x 1 m T1075 x 1 m T1209 x 1 m Speed controller AS3002F-06 AS4002F-10 AS4002F-12 AN30-03 Silencer AN302-03 Body Ported [when using SGP...

Open the catalog to page 5
5 Port Solenoid Valve - 6

Pilot Operated 5 Port Solenoid Valve Series VF1000/3000/5000 Single Unit Body Ported How to Order Valve Body ported VF 3 1 3 0 5 G Note) Only DIN and conduit terminal types are available with AC mode. Refer to the electrical entry for details. 1 01 Series 1 3 5 VF1000 VF3000 VF5000 Bracket Type of actuation 1 2 3 4 5 Nil F N T EA/EB port VF5000 3: Main/Pilot valve common Nil T VF1000 Double type only Standard With power saving circuit (DC only) Note) Be sure to select the power saving circuit type when it is continuously energized for long periods of time. (Refer to page 51 for details.) T...

Open the catalog to page 6
5 Port Solenoid Valve - 7

Pilot Operated 5 Port Solenoid Valve Body Ported/Single Unit Series VF1000/3000/5000 Specifications Model VF1000 VF3000 VF5000 Fluid Series VF1000 Series VF3000 Series VF5000 Air 0.15 to 0.7 Operating Standard 2-position single/3-position 2-position double 0.1 to 0.7 pressure Highrange 0.15 to 1.0 pressure 2-position single/3-position (MPa) type 2-position double 0.1 to 1.0 Ambient and fluid temperature ( C) –10 to 50 (No freezing) 10 10 5 2-position single/double Max. operating frequency (Hz) — 3 3 3-position Non-locking push type Push-turn locking slotted type Manual override Push-turn...

Open the catalog to page 7
5 Port Solenoid Valve - 9

Pilot Operated 5 Port Solenoid Valve Body Ported/Single Unit Series VF1000/3000/5000 Construction: Body Ported 2-position single VF1000 Symbol 2-position single VF1000 (B)2 4(A) u wr (B) (A) 2 4 qe (A)4 t w u q e (B) 2 (A) 4 y (EB)3 1 5(EA) (P) VF3000 VF5000 VF3000/5000 t 2(B) 3 1 5 (EB) (P) (EA) (EA)5 1 3(EB) (P) r 5 (EA) 1 (P) 3 (EB) y 2-position double Symbol 2-position single VF1000 (B)2 4(A) u wr t w u q (A) 4 (B) (A) 2 4 q (B) 2 (EB)3 1 5(EA) (P) VF3000 VF5000 (A)4 2(B) 3 1 5 (EB) (P) (EA) t (EA)5 1 3(EB) (P) 5 (EA) r 3-position closed center/exhaust center/pressure center Symbol (A)...

Open the catalog to page 9
5 Port Solenoid Valve - 10

Series VF1000/3000/5000 How to Order Pilot Valve Assembly (With a gasket and two mounting screws) Caution When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit type), or vice versa. Valve model: 5 G Z VF Select from the below in accordance with the valve used. 1 Grommet or L/M-type V2 11 5 G Z Light/Surge voltage suppressor Nil Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar) With light/surge voltage suppressor...

Open the catalog to page 10
5 Port Solenoid Valve - 11

Pilot Operated 5 Port Solenoid Valve Body Ported/Single Unit Series VF1000/3000/5000 Dimensions: Series VF1000/Body Ported 1-M5 (-F) 44.5 11.8 1.7 12 80 (6) (Lead wire length) (45) 17.5 2 x ø5.5 (For mounting) (1.6) 41.5 (16) (26) M5 x 0.8, 1/8 [1(P) port] 1.3 ø2.2 (PE port) 12 35 14.5 6 21.5 M5 x 0.8 [5(EA), 3(EB) port] ) s) ort 5EA 3EB G: Approx. 300 H: Approx. 600 ts np (6) (13 . (D 4) bet istan wee ce np orts ) (Indicator light) 4A 2B ee 80 (Lead wire length) - + (1.6) 41.5 Manual override tw G: Approx. 300 H: Approx. 600 10 4A 2B 26.4 Manual override 11.5 12 6) ce or 6. tan n p is e e...

Open the catalog to page 11
5 Port Solenoid Valve - 12

Series VF1000/3000/5000 Dimensions: Series VF1000/Body Ported 1/8 [4(A), 2(B) port] Manual override (Lead wire length) 44.5 47.5 124.4 (Lead wire length) 5EA 6 21.5 4A 11.5 G: Approx. 300 H: Approx. 600 (13 betw (Dis .4) een tance port s) (Indicator light) 1-01 (D 6.6 bet istanc ) w por een e ts) 2B 1.7 6 47.5 124.4 G: Approx. 300 H: Approx. 600 (1 12 26.4 4A 2B - + 10 26.4 1.7 .7) (11 nce ta n (Disetwee s) b port M5 x 0.8 [4(A), 2(B) port] Manual override G H Grommet (G) (H): VF1220- (4) 1-M5 1.7 G H 1.7 2-position double Grommet (G) (H): VF1220- M5 x 0.8, 1/8 [1(P) port] 1.3 2 x ø2.2 (PE...

Open the catalog to page 12

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36 Pages

  2. IDF series

    12 Pages

  3. MHL2 Series

    24 Pages

  4. JCM Serie

    18 Pages

  5. EX245 Series

    12 Pages

  6. SY

    268 Pages

  7. es70-44c-vx2

    52 Pages

  8. es50-37-kq2

    124 Pages

  9. ex-pcw

    23 Pages

  10. es20-230b-crb2

    59 Pages

  11. VH

    9 Pages

  12. CUJ

    41 Pages

  13. AL

    3 Pages

  14. kj mm

    9 Pages

  15. AQ

    4 Pages

  16. Series MB

    24 Pages

  17. Series LES

    23 Pages

  18. Series LEFB

    16 Pages

  19. Series PF3W

    28 Pages

  20. Series LEY

    7 Pages

  21. Series VHS

    12 Pages

  22. Series CY1S

    28 Pages

  23. AS series

    2 Pages

  24. ZP

    69 Pages

  25. ZFA

    14 Pages

  26. ZA

    13 Pages

  27. MHF

    32 Pages

  28. MHZ

    68 Pages

  29. CRB

    44 Pages

  30. D

    117 Pages

  31. RB

    23 Pages

  32. CEP

    44 Pages

  33. RSK

    30 Pages

  34. CLK

    51 Pages

  35. MK

    20 Pages

  36. GLJ

    65 Pages

  37. MGJ

    7 Pages

  38. Mx

    36 Pages

  39. MXH

    18 Pages

  40. My3

    56 Pages

  41. my1b

    20 Pages

  42. CC

    15 Pages

  43. J

    14 Pages

  44. CQ2

    51 Pages

  45. VFN

    6 Pages

  46. SY3000

    246 Pages

  47. SJ3A6

    18 Pages

  48. 1301/IW

    14 Pages

  49. CHQ/CHDQ

    19 Pages

  50. AC

    95 Pages

  51. HAW

    4 Pages

  52. HAA

    3 Pages

  53. ZB

    24 Pages

  54. CRB2

    35 Pages

  55. CJ1

    5 Pages

  56. SYJ

    62 Pages

  57. SJ

    78 Pages