cad

5 Port Solenoid Valve VQC
63Pages

{{requestButtons}}

Catalog excerpts

5 Port Solenoid Valve VQC - 1

5 Port Solenoid Valve i seal )[ Rubber seal) Connector Type Manifold Power saving (Reduced by 60% compared to existing model)

Open the catalog to page 1
5 Port Solenoid Valve VQC - 2

Connector Type Manifold Series VQC1000/2000 Power saving IP67 enclosure compatible Dust-tight, Immersion-proof Standard: W (Reduced by % compared to existing model) High-pressure (1 MPa, Metal seal): W Accommodates gateway-type serial wiring. Gateway unit types include DeviceNet™, PROFIBUS DP, and EtherNet/IP™. Because just one gateway unit controls up to 4 branch lines, it offers much more freedom in choosing valve mounting locations in comparison with other serial units. Manifolds and input blocks can be mounted near the actuator, allowing for use of short air piping or electric wiring....

Open the catalog to page 2
5 Port Solenoid Valve VQC - 3

Compact and high flow Flow-rate characteristics Note) Metal seal Rubber seal C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Applicable cylinder bore size (mm) Note) Flow-rate characteristics: 2-position single, 4/2 → 5/3 (A/B → R1/R2) Connector entry direction can be changed with a single push. (F/P kit) The connector entry direction can be changed from the top to the side by simply pressing the manual release button. It is not necessary to use the manual release button when switching from the side to the top. A wide variety of prepackaged wiring configurations S kit (Flat ribbon cable) Our six...

Open the catalog to page 3
5 Port Solenoid Valve VQC - 4

Series VQC/Base Sonic conductance C [dm3/(s·bar)] Applicable cylinder bore size Serial transmission Gateway application Compatible network Compatible network • DeviceNet™ • DeviceNet™ • PROFIBUS DP • PROFIBUS DP • EtherNet/IP™ • CC-Link Decentralized • EtherNet/IP™ Serial Wiring • EtherCAT Gateway application • PROFINET requires a gateway unit and communication cable separately. Please contact SMC for details. Compatible network Compatible network • DeviceNet™ • PROFIBUS DP • CC-Link • AS-Interface • CANopen • EtherNet/IP™ • DeviceNet™ • CC-Link • PROFIBUS DP Output • CC-Link • EtherCAT •...

Open the catalog to page 4
5 Port Solenoid Valve VQC - 5

5 Port Solenoid Valve D-sub connector Flat ribbon cable Terminal block box Electrical entry D-sub connector Conforming to MIL D-sub connector Flat ribbon cable Conforming to MIL flat ribbon cable connector (Terminal block) Terminal block is compactly arranged on one side. Lead wire IP67 enclosure with use of multiple wire cable with sheath and waterproof connector Port size Circular connector Circular connector IP67 enclosure with use of waterproof circular connector Cylinder port 26 pins 25-core cable 25 pins

Open the catalog to page 5
5 Port Solenoid Valve VQC - 6

Cylinder Speed Chart This chart is provided as guidelines only. For performance under various conditions, use SMC's Model Selection Program before making a judgment. Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm ø6 Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm ø40 Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Perpendicular, upward actuation Horizontal actuation ∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. ∗ The...

Open the catalog to page 6
5 Port Solenoid Valve VQC - 7

VQC1000/2000 Model, Standard/Manifold Specifications. .. P. 1172 0kit (Serial transmission [Fieldbus system]) EX600 0 kit (Serial transmission) EX250 p -j-jgo Q kit (Flat ribbon cable) p -|-|gg

Open the catalog to page 7
5 Port Solenoid Valve VQC - 8

Base Mounted Plug-in Unit Series VQC1000 How to Order Manifold Base mounted plug-in Enter EX600-compliant S kit only. ······ Stations 01 The maximum number of stations differs depending on the electrical entry. (Refer to Kit type/Electrical entry/Cable length.) Note) In case of compatibility with the S kit/AS-Interface, the maximum number of solenoids is as shown below, so please be careful of the number of stations. • 8 in/8 out: Maximum 8 solenoids • 4 in/4 out: Maximum 4 solenoids Cylinder port size ····· Enter EX250-compliant S kit only. Input block specification PNP sensor input...

Open the catalog to page 8
5 Port Solenoid Valve VQC - 9

Base Mounted Plug-in Unit SJ ∗ Numbers in parentheses represent the maximum number of solenoids in case of mixed single and double wiring. The maximum number of stations is determined by the total number of solenoids. When ordering mixed wiring, please add the option symbol “-K”. Kit type/Electrical entry/Cable length (Serial transmission: EX500 gateway-type) (Serial transmission (Fieldbus system): EX600 integrated-type (I/O)) Note) A separate gateway unit and communication cable are required. (Serial transmission: EX260 integrated-type (for output)) Without SI unit DeviceNet™ PROFIBUS DP...

Open the catalog to page 9
5 Port Solenoid Valve VQC - 10

Series VQC1000 SI Unit Part No. EX500 Symbol Positive common (NPN) Negative common (PNP) Positive common (NPN) Negative common (PNP) AS-Interface, 4 in/4 out, 31 slave modes, EX250-SAS5 2 power supply systems AS-Interface, 8 in/8 out, 31 slave modes, EX250-SAS7 1 power supply systems AS-Interface, 4 in/4 out, 31 slave modes, EX250-SAS9 1 power supply systems SDY CANopen SDZEN EtherNet/IP™ Number SI unit part no. Communication of connector outputs Positive common (NPN) Negative common (PNP) EtherCAT PROFINET EtherNet/IP™ Note) When the communication connector specification is D-sub, the...

Open the catalog to page 10
5 Port Solenoid Valve VQC - 11

Plug-in Unit Base Mounted Note) Rubber seal only Nil: Non-locking push type (Tool required) A Standard (0.4 W) High-speed response type (0.95 W) High-pressure type (1.0 MPa, 0.95 W) Negative common External pilot C: Locking type (Manual) VQ5 D: Slide locking type Light/surge voltage suppressor Note) Only 24 VDC is available with the S kit. (Tool required) Coil voltage Note 1) When two or more symbols are specified, indicate them alphabetically. However, combination of “B” and “K” is not possible. Note 2) Metal seal only Note 3) When “-COM.” is specified for the SI unit, select and mount the...

Open the catalog to page 11
5 Port Solenoid Valve VQC - 12

Series VQC1000 Refer to pages 1202 through to 1205 for details. Blanking plate assembly C6 (EXH port) ø6 One-touch fitting C6 (SUP port) ø6 One-touch fitting Blanking plate with connector Back pressure check valve assembly [-B] EXH block plate assembly C3, C4 Name plate [-N] VVQ1000- N -(1 to Max. stations) NC Connector assembly Manifold Options IP40 compliant DIN rail mounting bracket [-D] Blanking plug Direct EXH outlet with built-in silencer [-S] Elbow fitting assembly Port plug Dual flow fitting assembly Special electrical wiring specifications [-K] Wiring example) D-sub connector...

Open the catalog to page 12

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36 Pages

  2. IDF series

    12 Pages

  3. MHL2 Series

    24 Pages

  4. JCM Serie

    18 Pages

  5. EX245 Series

    12 Pages

  6. SY

    268 Pages

  7. es70-44c-vx2

    52 Pages

  8. es50-37-kq2

    124 Pages

  9. ex-pcw

    23 Pages

  10. es20-230b-crb2

    59 Pages

  11. VH

    9 Pages

  12. CUJ

    41 Pages

  13. AL

    3 Pages

  14. kj mm

    9 Pages

  15. AQ

    4 Pages

  16. Series MB

    24 Pages

  17. Series LES

    23 Pages

  18. Series LEFB

    16 Pages

  19. Series PF3W

    28 Pages

  20. Series LEY

    7 Pages

  21. Series VHS

    12 Pages

  22. Series CY1S

    28 Pages

  23. AS series

    2 Pages

  24. ZP

    69 Pages

  25. ZFA

    14 Pages

  26. ZA

    13 Pages

  27. MHF

    32 Pages

  28. MHZ

    68 Pages

  29. CRB

    44 Pages

  30. D

    117 Pages

  31. RB

    23 Pages

  32. CEP

    44 Pages

  33. RSK

    30 Pages

  34. CLK

    51 Pages

  35. MK

    20 Pages

  36. GLJ

    65 Pages

  37. MGJ

    7 Pages

  38. Mx

    36 Pages

  39. MXH

    18 Pages

  40. My3

    56 Pages

  41. my1b

    20 Pages

  42. CC

    15 Pages

  43. J

    14 Pages

  44. CQ2

    51 Pages

  45. VFN

    6 Pages

  46. SY3000

    246 Pages

  47. SJ3A6

    18 Pages

  48. 1301/IW

    14 Pages

  49. CHQ/CHDQ

    19 Pages

  50. AC

    95 Pages

  51. HAW

    4 Pages

  52. HAA

    3 Pages

  53. ZB

    24 Pages

  54. CRB2

    35 Pages

  55. CJ1

    5 Pages

  56. SYJ

    62 Pages

  57. SJ

    78 Pages

Archived catalogs