1. Catalogs
  2. SMC PNEUMATIC
  3. 5 Port Solenoid Valve VQC

5 Port Solenoid Valve VQC

5 Port Solenoid Valve VQC
1 / 63 PagesView full catalog

5 Port Solenoid Valve VQC

Product catalog summary
Overview: The document provides comprehensive details on the Series VQC1000/2000 5 Port Solenoid Valve, emphasizing its power-saving features, compatibility with various fieldbus systems, and flexible manifold configurations.
Specifications:
  • RoHS compliant and IP67 enclosure for dust-tight and immersion-proof protection.
  • Power consumption reduced by 60% compared to previous models, with standard usage at 0.4 W and high-pressure usage at 0.95 W.
  • Compatible with fieldbus protocols such as DeviceNet™, PROFIBUS DP, CC-Link, EtherNet/IP™, EtherCAT, and PROFINET.
Features:
  • Self-diagnosis function for maintenance prediction and part identification.
  • Flexible manifold configurations with metal and rubber seal options.
  • Connector type manifold with M12/M8 connector selection.
  • Gateway unit types for decentralized serial wiring, accommodating up to 9 units.
Manifold Options:
  • Kits available for various wiring needs, including D-sub connector, flat ribbon cable, terminal block box, and circular connector.
  • Manifold pitch options of 10.5 mm and 16 mm, with flow-rate characteristics for different configurations.
  • Adjustable connector entry direction for flexible installation.
Applications:
  • Suitable for cylinder bore sizes up to ø80 mm.
  • Usable in configurations like dual 3-port valves and 4-position, 5-port type valves.
Additional Information:
  • Includes a cylinder speed chart for performance guidelines.
  • Detailed ordering information and manifold options for customization.
Procedures:
Instructions for ordering and installing manifold options, using specific codes for port sizes and mounting positions. Procedure for removing port plugs using an M3 screw.
Norms and Standards:
References JIS B 8375-1981 for supply pressure standards and guidelines for cylinder operation and air leakage prevention.
Recommendations:
Use screw piping with M5 threads for long-term cylinder stopping, check for air leakage with detergent, and ensure proper tightening torque. Avoid combining certain valve types with double check blocks.
Key Components and Options:
  • Double Check Block: Maintains cylinder position with a built-in pilot type double check valve and a 3-position exhaust center solenoid valve.
  • Back Pressure Check Valve: Prevents cylinder malfunction due to exhaust entry from other valves.
  • Silencer: Recommended for EXH ports to reduce noise.
  • Individual SUP/EXH Spacers: For individual valve exhaust and supply pressure management.
Dimensions and Formulas:
Detailed dimensions and formulas for calculating manifold lengths based on station count, with tables for L1, L2, and L3 dimensions.
Warnings and Cautions:
Highlights potential air leakage from fittings, importance of proper tightening torque, and avoiding excessive restriction of exhaust in double check blocks. Advises against certain fitting and solenoid valve combinations.
Manual Override and Solenoid Valve Handling:
Instructions for operating manual overrides and mounting/removing solenoid valves, emphasizing proper torque to avoid air leakage.
Fitting Assembly and Replacement:
Process for replacing cylinder port fittings, avoiding scratches and dust on O-rings, and specifying part numbers for fitting assemblies.
Safety Instructions:
Includes need for qualified personnel, grounding for noise reduction, periodic inspections, and warnings against use in explosive or corrosive environments.
EX600 Precautions:
Outlines specific precautions for the EX600 series, including operating within specified ranges and proper mounting and wiring to maintain IP67 protection.
Wiring Precautions:
  • Avoid excessive bending or stretching of cables.
  • Ensure correct wiring to prevent malfunction or damage.
  • Do not wire while energized to prevent damage.
Power Supply and Installation:
  • Use a class 2 power supply unit as per UL1310 for compliance.
  • Operate within specified voltage ranges.
  • Ensure 0 V standard for output and control/input power supplies.
  • Maintain adequate space for maintenance.
Operating Environment:
  • Avoid flammable or explosive atmospheres.
  • Protect against noise and static electricity.
  • Avoid environments with oil, chemicals, or corrosive substances.
Adjustment and Maintenance:
  • Do not operate with wet hands to avoid electrical shock.
  • Ensure safety when using forced input/output functions.
  • Perform periodic inspections and functionality checks after maintenance.
See more

Catalog excerpts

5 Port Solenoid Valve VQC-1

5 Port Solenoid Valve i seal )[ Rubber seal) Connector Type Manifold Power saving (Reduced by 60% compared to existing model)

 Open the catalog to page 1
5 Port Solenoid Valve VQC-2

Connector Type Manifold Series VQC1000/2000 Power saving IP67 enclosure compatible Dust-tight, Immersion-proof Standard: W (Reduced by % compared to existing model) High-pressure (1 MPa, Metal seal): W Accommodates gateway-type serial wiring. Gateway unit types include DeviceNet™, PROFIBUS DP, and EtherNet/IP™. Because just one gateway unit controls up to 4 branch lines, it offers much more freedom in choosing valve mounting locations in comparison with other serial units. Manifolds and input blocks can be mounted near the actuator, allowing for use of short air piping or electric wiring. The...

 Open the catalog to page 2
5 Port Solenoid Valve VQC-3

Compact and high flow Flow-rate characteristics Note) Metal seal Rubber seal C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Applicable cylinder bore size (mm) Note) Flow-rate characteristics: 2-position single, 4/2 → 5/3 (A/B → R1/R2) Connector entry direction can be changed with a single push. (F/P kit) The connector entry direction can be changed from the top to the side by simply pressing the manual release button. It is not necessary to use the manual release button when switching from the side to the top. A wide variety of prepackaged wiring configurations S kit (Flat ribbon cable) Our six standard...

 Open the catalog to page 3
5 Port Solenoid Valve VQC-4

Series VQC/Base Sonic conductance C [dm3/(s·bar)] Applicable cylinder bore size Serial transmission Gateway application Compatible network Compatible network • DeviceNet™ • DeviceNet™ • PROFIBUS DP • PROFIBUS DP • EtherNet/IP™ • CC-Link Decentralized • EtherNet/IP™ Serial Wiring • EtherCAT Gateway application • PROFINET requires a gateway unit and communication cable separately. Please contact SMC for details. Compatible network Compatible network • DeviceNet™ • PROFIBUS DP • CC-Link • AS-Interface • CANopen • EtherNet/IP™ • DeviceNet™ • CC-Link • PROFIBUS DP Output • CC-Link • EtherCAT • PROFINET...

 Open the catalog to page 4
5 Port Solenoid Valve VQC-5

5 Port Solenoid Valve D-sub connector Flat ribbon cable Terminal block box Electrical entry D-sub connector Conforming to MIL D-sub connector Flat ribbon cable Conforming to MIL flat ribbon cable connector (Terminal block) Terminal block is compactly arranged on one side. Lead wire IP67 enclosure with use of multiple wire cable with sheath and waterproof connector Port size Circular connector Circular connector IP67 enclosure with use of waterproof circular connector Cylinder port 26 pins 25-core cable 25 pins

 Open the catalog to page 5
5 Port Solenoid Valve VQC-6

Cylinder Speed Chart This chart is provided as guidelines only. For performance under various conditions, use SMC's Model Selection Program before making a judgment. Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm ø6 Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm ø40 Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Perpendicular, upward actuation Horizontal actuation ∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. ∗ The average...

 Open the catalog to page 6
5 Port Solenoid Valve VQC-7

VQC1000/2000 Model, Standard/Manifold Specifications. .. P. 1172 0kit (Serial transmission [Fieldbus system]) EX600 0 kit (Serial transmission) EX250 p -j-jgo Q kit (Flat ribbon cable) p -|-|gg

 Open the catalog to page 7
5 Port Solenoid Valve VQC-8

Base Mounted Plug-in Unit Series VQC1000 How to Order Manifold Base mounted plug-in Enter EX600-compliant S kit only. ······ Stations 01 The maximum number of stations differs depending on the electrical entry. (Refer to Kit type/Electrical entry/Cable length.) Note) In case of compatibility with the S kit/AS-Interface, the maximum number of solenoids is as shown below, so please be careful of the number of stations. • 8 in/8 out: Maximum 8 solenoids • 4 in/4 out: Maximum 4 solenoids Cylinder port size ····· Enter EX250-compliant S kit only. Input block specification PNP sensor input (Positive...

 Open the catalog to page 8
5 Port Solenoid Valve VQC-9

Base Mounted Plug-in Unit SJ ∗ Numbers in parentheses represent the maximum number of solenoids in case of mixed single and double wiring. The maximum number of stations is determined by the total number of solenoids. When ordering mixed wiring, please add the option symbol “-K”. Kit type/Electrical entry/Cable length (Serial transmission: EX500 gateway-type) (Serial transmission (Fieldbus system): EX600 integrated-type (I/O)) Note) A separate gateway unit and communication cable are required. (Serial transmission: EX260 integrated-type (for output)) Without SI unit DeviceNet™ PROFIBUS DP CC-Link...

 Open the catalog to page 9
5 Port Solenoid Valve VQC-10

Series VQC1000 SI Unit Part No. EX500 Symbol Positive common (NPN) Negative common (PNP) Positive common (NPN) Negative common (PNP) AS-Interface, 4 in/4 out, 31 slave modes, EX250-SAS5 2 power supply systems AS-Interface, 8 in/8 out, 31 slave modes, EX250-SAS7 1 power supply systems AS-Interface, 4 in/4 out, 31 slave modes, EX250-SAS9 1 power supply systems SDY CANopen SDZEN EtherNet/IP™ Number SI unit part no. Communication of connector outputs Positive common (NPN) Negative common (PNP) EtherCAT PROFINET EtherNet/IP™ Note) When the communication connector specification is D-sub, the enclosure...

 Open the catalog to page 10
5 Port Solenoid Valve VQC-11

Plug-in Unit Base Mounted Note) Rubber seal only Nil: Non-locking push type (Tool required) A Standard (0.4 W) High-speed response type (0.95 W) High-pressure type (1.0 MPa, 0.95 W) Negative common External pilot C: Locking type (Manual) VQ5 D: Slide locking type Light/surge voltage suppressor Note) Only 24 VDC is available with the S kit. (Tool required) Coil voltage Note 1) When two or more symbols are specified, indicate them alphabetically. However, combination of “B” and “K” is not possible. Note 2) Metal seal only Note 3) When “-COM.” is specified for the SI unit, select and mount the valve...

 Open the catalog to page 11

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36  Pages

  2. IDF series

    12  Pages

  3. MHL2 Series

    24  Pages

  4. JCM Serie

    18  Pages

  5. EX245 Series

    12  Pages

  6. SY

    268  Pages

  7. es70-44c-vx2

    52  Pages

  8. es50-37-kq2

    124  Pages

  9. ex-pcw

    23  Pages

  10. es20-230b-crb2

    59  Pages

  11. VH

    9  Pages

  12. CUJ

    41  Pages

  13. AL

    3  Pages

  14. kj mm

    9  Pages

  15. AQ

    4  Pages

  16. Series MB

    24  Pages

  17. Series LES

    23  Pages

  18. Series LEFB

    16  Pages

  19. Series PF3W

    28  Pages

  20. Series LEY

    7  Pages

  21. Series VHS

    12  Pages

  22. Series CY1S

    28  Pages

  23. AS series

    2  Pages

  24. corporate guide

    13  Pages

  25. ZP

    69  Pages

  26. ZFA

    14  Pages

  27. ZA

    13  Pages

  28. MHF

    32  Pages

  29. MHZ

    68  Pages

  30. CRB

    44  Pages

  31. D

    117  Pages

  32. RB

    23  Pages

  33. CEP

    44  Pages

  34. RSK

    30  Pages

  35. CLK

    51  Pages

  36. MK

    20  Pages

  37. GLJ

    65  Pages

  38. MGJ

    7  Pages

  39. Mx

    36  Pages

  40. MXH

    18  Pages

  41. My3

    56  Pages

  42. my1b

    20  Pages

  43. CC

    15  Pages

  44. J

    14  Pages

  45. CQ2

    51  Pages

  46. VFN

    6  Pages

  47. SY3000

    246  Pages

  48. SJ3A6

    18  Pages

  49. 1301/IW

    14  Pages

  50. CHQ/CHDQ

    19  Pages

  51. AC

    95  Pages

  52. HAW

    4  Pages

  53. HAA

    3  Pages

  54. ZB

    24  Pages

  55. CRB2

    35  Pages

Archived catalogs

  1. CJ1

    5  Pages

  2. SYJ

    62  Pages

  3. SJ

    78  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.