cad

1-p1869-1878-vp3145
10Pages

{{requestButtons}}

Catalog excerpts

1-p1869-1878-vp3145 - 1

Large Size 3 Port Solenoid Valve Series VP3145/3165/3185 Rubber Seal Large flow capacity, small exhaust resistance (Refer to “Flow Characteristic” table.) Note) CE-compliant: D/DL/DS/DZ only (Electrical entry) Series VP 3 port Function plate makes it possible to use solenoid valve as a N.C. or N.O. valve with the port Number of unchanged. solenoids Possible to use in vacuum or under low pressures CE-compliant CE-compliant Note) Note) Electrical entry: D/DL/DS/DZ only Body size Free mounting orientation Thread type Body ported For general For vacuum/low pressure A N.C. (Normally closed) B N.O. (Normally open) Port size Symbol Rc (Nominal size) VP3145 VP3165 VP3185 Symbol Internal pilot Electrical entry How to Order Pilot Valve Assembly G Grommet Conduit terminal T D DIN terminal TL∗ Conduit terminal with indicator light TS∗ Conduit terminal with surge voltage suppressor TZ∗ Conduit terminal with light/surge voltage suppressor DL∗ DIN terminal with indicator light DS∗ DIN terminal with surge voltage suppressor DZ∗ DIN terminal with light/surge voltage suppressor Standard (Internal pilot) External pilot Pilot option Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot. Made to Order (Refer to pages 1875 to 1877 for details.) Coil rated voltage G Grommet 1 100 VAC, 50/60 Hz Conduit terminal T 2 200 VAC, 50/60 Hz D DIN terminal CE-compliant 3∗ 110 VAC, 50/60 Hz TL∗ Conduit terminal with indicator light — Nil 4∗ 220 VAC, 50/60 Hz TS∗ Conduit terminal with surge voltage suppressor Q CE-compliant Note) 5 24 VDC TZ∗ Conduit terminal with light/surge voltage suppressor Note) Electrical entry: 6∗ 12 VDC DL∗ DIN terminal with indicator light D/DL/DS/DZ only 7∗ 240 VAC, 50/60 Hz DS∗ DIN terminal with surge voltage suppressor 9∗ Other DZ∗ DIN terminal with light/surge voltage suppressor ∗ Semi-standard ∗ Semi-standard Note) The pilot valve assembly shown above includes the function plate and gasket.

Open the catalog to page 1
1-p1869-1878-vp3145 - 2

External Pilot Use external pilot model in the following cases. • Vacuum or low pressure (0.2 MPa or less): Vacuum/Low pressure type • Using the valve with supply port external throttle: General type • Air pressure of supply port is slow: General type • Resistance in outlet side is small in case of air blowing or filling an air tank: General type Note 1) Keep external pilot pressure within the pressure range below. Note 2) Conversion of internal pilot and external pilot can not be done. Fluid Type of actuation Air N.C. or N.O. (Convertible) External pilot Internal pilot For general For...

Open the catalog to page 2
1-p1869-1878-vp3145 - 3

Large Size 3 Port Solenoid Valve Construction/Internal Pilot As in the figure below, this pilot-operated solenoid valve consists of a compact 3 port solenoid valve as the pilot valve and a large 3 port valve as the main valve. The pilot valve controls opening and closing the main valve. N.C. or N.O. function conversion can be done by switching the pilot passage. Overtravel spring Keeps surface pressure against the valve constant and compensates for stroke. Pilot valve Solenoid Manual override Return spring Pilot air supply port Internal pilot Function plate N.C. or N.O. conversion possible...

Open the catalog to page 3
1-p1869-1878-vp3145 - 4

Manual override External pilot port Lead wire length 200 mm Mounting hole Note) External pilot port Rc 1/4 is processed for threads in external pilot model only. A B Conduit terminal with indicator light (TL) Light [ ]: With indicator light (TL) Light position

Open the catalog to page 4
1-p1869-1878-vp3145 - 5

Large Size 3 Port Solenoid Valve Manual override External pilot port Lead wire length 200 mm (EXH port) Mounting hole Note) External pilot port Rc 1/4 is processed for threads in external pilot model only. Conduit terminal: VP3165-T A B Conduit terminal with indicator light (TL) Light DIN terminal: VP3165-DA B Light position [ ]: With indicator light (TL)

Open the catalog to page 5
1-p1869-1878-vp3145 - 6

Manual override External pilot port Lead wire length 200 mm (PE port) (EXH port) Mounting hole Note) External pilot port Rc 1/4 is processed for threads in external pilot model only. A B Conduit terminal with indicator light (TL) Light Light position [ ]: With indicator light (TL)

Open the catalog to page 6
1-p1869-1878-vp3145 - 7

Note) CE-compliant: D/DO only (Electrical entry) Please contact SMC for detailed dimensions, specifications and lead times. 1 Main Value Double Acting Type CE marking Port size (IN, OUT port) Grommet (300 mm) Grommet (600 mm) Conduit terminal With connector DIN terminal Without connector With lead wire L plug Without lead wire connector Without connector With lead wire M plug Without lead wire connector Without connector Thread type None CE-compliant∗ Double solenoid Single solenoid External pilot Passage, Type of actuation U, Z spec. CE-compliant ∗ In the case of -X80, only N.C. is...

Open the catalog to page 7
1-p1869-1878-vp3145 - 8

Valve configuration Type of actuation Fluid Operating pressure range Pilot pressure Ambient and fluid temperature Lubrication Note 1) Mounting orientation Impact/Vibration resistance Note 2) Note 1) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32). Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a...

Open the catalog to page 8
1-p1869-1878-vp3145 - 9

Large Size 3 Port Solenoid Valve Manual override (Non-locking) 1/4 (External pilot port) 2 x ø8.5 (For mounting) • In the case of B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face. • In the case of -X80, VF3240K-1 (Pilot valve) will be mounted. Manual override (Non-locking) Applicable cable O.D. ø4.5 to ø7 1/4 (External pilot port) • In the case of B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face. • In the case of -X80, VF3240K-1 (Pilot valve)...

Open the catalog to page 9

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36 Pages

  2. IDF series

    12 Pages

  3. MHL2 Series

    24 Pages

  4. JCM Serie

    18 Pages

  5. EX245 Series

    12 Pages

  6. SY

    268 Pages

  7. es70-44c-vx2

    52 Pages

  8. es50-37-kq2

    124 Pages

  9. ex-pcw

    23 Pages

  10. es20-230b-crb2

    59 Pages

  11. VH

    9 Pages

  12. CUJ

    41 Pages

  13. AL

    3 Pages

  14. kj mm

    9 Pages

  15. AQ

    4 Pages

  16. Series MB

    24 Pages

  17. Series LES

    23 Pages

  18. Series LEFB

    16 Pages

  19. Series PF3W

    28 Pages

  20. Series LEY

    7 Pages

  21. Series VHS

    12 Pages

  22. Series CY1S

    28 Pages

  23. AS series

    2 Pages

  24. ZP

    69 Pages

  25. ZFA

    14 Pages

  26. ZA

    13 Pages

  27. MHF

    32 Pages

  28. MHZ

    68 Pages

  29. CRB

    44 Pages

  30. D

    117 Pages

  31. RB

    23 Pages

  32. CEP

    44 Pages

  33. RSK

    30 Pages

  34. CLK

    51 Pages

  35. MK

    20 Pages

  36. GLJ

    65 Pages

  37. MGJ

    7 Pages

  38. Mx

    36 Pages

  39. MXH

    18 Pages

  40. My3

    56 Pages

  41. my1b

    20 Pages

  42. CC

    15 Pages

  43. J

    14 Pages

  44. CQ2

    51 Pages

  45. VFN

    6 Pages

  46. SY3000

    246 Pages

  47. SJ3A6

    18 Pages

  48. 1301/IW

    14 Pages

  49. CHQ/CHDQ

    19 Pages

  50. AC

    95 Pages

  51. HAW

    4 Pages

  52. HAA

    3 Pages

  53. ZB

    24 Pages

  54. CRB2

    35 Pages

  55. CJ1

    5 Pages

  56. SYJ

    62 Pages

  57. SJ

    78 Pages

Archived catalogs