Group: SMC
Catalog excerpts
Large Size 3 Port Solenoid Valve Series VP3145/3165/3185 Rubber Seal Large flow capacity, small exhaust resistance (Refer to “Flow Characteristic” table.) Note) CE-compliant: D/DL/DS/DZ only (Electrical entry) Series VP 3 port Function plate makes it possible to use solenoid valve as a N.C. or N.O. valve with the port Number of unchanged. solenoids Possible to use in vacuum or under low pressures CE-compliant CE-compliant Note) Note) Electrical entry: D/DL/DS/DZ only Body size Free mounting orientation Thread type Body ported For general For vacuum/low pressure A N.C. (Normally closed) B N.O. (Normally open) Port size Symbol Rc (Nominal size) VP3145 VP3165 VP3185 Symbol Internal pilot Electrical entry How to Order Pilot Valve Assembly G Grommet Conduit terminal T D DIN terminal TL∗ Conduit terminal with indicator light TS∗ Conduit terminal with surge voltage suppressor TZ∗ Conduit terminal with light/surge voltage suppressor DL∗ DIN terminal with indicator light DS∗ DIN terminal with surge voltage suppressor DZ∗ DIN terminal with light/surge voltage suppressor Standard (Internal pilot) External pilot Pilot option Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot. Made to Order (Refer to pages 1875 to 1877 for details.) Coil rated voltage G Grommet 1 100 VAC, 50/60 Hz Conduit terminal T 2 200 VAC, 50/60 Hz D DIN terminal CE-compliant 3∗ 110 VAC, 50/60 Hz TL∗ Conduit terminal with indicator light — Nil 4∗ 220 VAC, 50/60 Hz TS∗ Conduit terminal with surge voltage suppressor Q CE-compliant Note) 5 24 VDC TZ∗ Conduit terminal with light/surge voltage suppressor Note) Electrical entry: 6∗ 12 VDC DL∗ DIN terminal with indicator light D/DL/DS/DZ only 7∗ 240 VAC, 50/60 Hz DS∗ DIN terminal with surge voltage suppressor 9∗ Other DZ∗ DIN terminal with light/surge voltage suppressor ∗ Semi-standard ∗ Semi-standard Note) The pilot valve assembly shown above includes the function plate and gasket.
Open the catalog to page 1External Pilot Use external pilot model in the following cases. • Vacuum or low pressure (0.2 MPa or less): Vacuum/Low pressure type • Using the valve with supply port external throttle: General type • Air pressure of supply port is slow: General type • Resistance in outlet side is small in case of air blowing or filling an air tank: General type Note 1) Keep external pilot pressure within the pressure range below. Note 2) Conversion of internal pilot and external pilot can not be done. Fluid Type of actuation Air N.C. or N.O. (Convertible) External pilot Internal pilot For general For...
Open the catalog to page 2Large Size 3 Port Solenoid Valve Construction/Internal Pilot As in the figure below, this pilot-operated solenoid valve consists of a compact 3 port solenoid valve as the pilot valve and a large 3 port valve as the main valve. The pilot valve controls opening and closing the main valve. N.C. or N.O. function conversion can be done by switching the pilot passage. Overtravel spring Keeps surface pressure against the valve constant and compensates for stroke. Pilot valve Solenoid Manual override Return spring Pilot air supply port Internal pilot Function plate N.C. or N.O. conversion possible...
Open the catalog to page 3Manual override External pilot port Lead wire length 200 mm Mounting hole Note) External pilot port Rc 1/4 is processed for threads in external pilot model only. A B Conduit terminal with indicator light (TL) Light [ ]: With indicator light (TL) Light position
Open the catalog to page 4Large Size 3 Port Solenoid Valve Manual override External pilot port Lead wire length 200 mm (EXH port) Mounting hole Note) External pilot port Rc 1/4 is processed for threads in external pilot model only. Conduit terminal: VP3165-T A B Conduit terminal with indicator light (TL) Light DIN terminal: VP3165-DA B Light position [ ]: With indicator light (TL)
Open the catalog to page 5Manual override External pilot port Lead wire length 200 mm (PE port) (EXH port) Mounting hole Note) External pilot port Rc 1/4 is processed for threads in external pilot model only. A B Conduit terminal with indicator light (TL) Light Light position [ ]: With indicator light (TL)
Open the catalog to page 6Note) CE-compliant: D/DO only (Electrical entry) Please contact SMC for detailed dimensions, specifications and lead times. 1 Main Value Double Acting Type CE marking Port size (IN, OUT port) Grommet (300 mm) Grommet (600 mm) Conduit terminal With connector DIN terminal Without connector With lead wire L plug Without lead wire connector Without connector With lead wire M plug Without lead wire connector Without connector Thread type None CE-compliant∗ Double solenoid Single solenoid External pilot Passage, Type of actuation U, Z spec. CE-compliant ∗ In the case of -X80, only N.C. is...
Open the catalog to page 7Valve configuration Type of actuation Fluid Operating pressure range Pilot pressure Ambient and fluid temperature Lubrication Note 1) Mounting orientation Impact/Vibration resistance Note 2) Note 1) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32). Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a...
Open the catalog to page 8Large Size 3 Port Solenoid Valve Manual override (Non-locking) 1/4 (External pilot port) 2 x ø8.5 (For mounting) • In the case of B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face. • In the case of -X80, VF3240K-1 (Pilot valve) will be mounted. Manual override (Non-locking) Applicable cable O.D. ø4.5 to ø7 1/4 (External pilot port) • In the case of B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face. • In the case of -X80, VF3240K-1 (Pilot valve)...
Open the catalog to page 9All SMC PNEUMATIC catalogs and technical brochures
-
SYJ300/500/700 Series
62 Pages
-
Vacuum Unit ZK2 Series
60 Pages
-
Air Cylinder CJ2 Series
117 Pages
-
AS-FS Series
36 Pages
-
IDF series
12 Pages
-
MHL2 Series
24 Pages
-
JCM Serie
18 Pages
-
EX245 Series
12 Pages
-
Pin Cylinder CJP2/CDJP2/CJP
19 Pages
-
5 Port Solenoid Valve VQC
63 Pages
-
5 Port Solenoid Valve VQ
79 Pages
-
SY
268 Pages
-
5-p0979-0980-hep500
2 Pages
-
5-p0977-0978-aep100
2 Pages
-
5-p0966-0971-lmu
5 Pages
-
5-p0960-0966-alb900
6 Pages
-
5-p0956-0960-ald600
5 Pages
-
5-p0948-0950-al800
3 Pages
-
es70-44c-vx2
52 Pages
-
es50-37-kq2
124 Pages
-
ex-pcw
23 Pages
-
1-p2124-2152-ex510
29 Pages
-
1-p2111-2122-ex500
12 Pages
-
1-p2063-2073-ex260
11 Pages
-
4-p0147-0178-msu-mds
32 Pages
-
es20-230b-crb2
59 Pages
-
VP300/500/700 series
42 Pages
-
1-p1789-1829-vqz100
41 Pages
-
1-p1727-1788-syj300
62 Pages
-
5 Port Solenoid Valve S0700
111 Pages
-
5 Port Solenoid Valve VF
59 Pages
-
5 Port Solenoid Valve SV
127 Pages
-
VH
9 Pages
-
CUJ
41 Pages
-
AL
3 Pages
-
kj mm
9 Pages
-
AQ
4 Pages
-
SY3000/5000-X13
2 Pages
-
Series MB
24 Pages
-
Series LES
23 Pages
-
Series LEFB
16 Pages
-
Series PF3W
28 Pages
-
Series IDG?A/IDG
56 Pages
-
Floating Joint
7 Pages
-
Series IZS40/41/42
32 Pages
-
Series LEY
7 Pages
-
Series VHS
12 Pages
-
Series CY1S
28 Pages
-
SeriesCQ2/CQS/CQ
4 Pages
-
In-line Air Filter
12 Pages
-
5 Port Solenoid Valve
60 Pages
-
Series CQ2/CQS
2 Pages
-
AS series
2 Pages
-
corporate guide
13 Pages
-
ZP
69 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
MHZ
68 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
RSK
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
GLJ
65 Pages
-
MGJ
7 Pages
-
Mx
36 Pages
-
MXH
18 Pages
-
My3
56 Pages
-
my1b
20 Pages
-
CC
15 Pages
-
J
14 Pages
-
CQ2
51 Pages
-
standard cylinder
84 Pages
-
VFN
6 Pages
-
SY3000
246 Pages
-
SJ3A6
18 Pages
-
1301/IW
14 Pages
-
CHQ/CHDQ
19 Pages
-
AC
95 Pages
-
HAW
4 Pages
-
HAA
3 Pages
-
ZB
24 Pages
-
CRB2
35 Pages
-
CJ1
5 Pages
-
SYJ
62 Pages
-
SJ
78 Pages