Group: SMC
Catalog excerpts
3 Port Solenoid Valve Series Selectable power consumption! Low wattage specification added ∗ VP300/500 Power consumption 0.35 W (Without light) 0.4 W (With light) [With power saving circuit] [Starting 1.55 W, Holding 0.55 W] ∗ Conventional model: 2.0 W With DC light Power consumption is reduced by power saving circuit. Built-in full-wave rectifier (AC) Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state.(Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown below. Electrical power waveform of energy saving type Applied voltage Noise is considerably reduced by changing it to DC mode with a full-wave rectifier. apparent power Conventional 5.6 VA → 1.55 VA [Standard] Longer life expectancy: 50 million cycles or more (Conventional: 20 million cycles) ∗ Based on SMC test conditions. Energy saving strainer in the pilot valve Unexpected troubles due to foreign matter can be prevented. Rubber material: HNBR Note) Be sure to mount an air filter on the inlet side. With power saving circuit Ozone-resistant specification ∗ The pilot valve poppet is made of FKM.
Open the catalog to page 1Model Selection by Operating Conditions q Solenoid Valve: Single Unit Series Port size Electrical entry Light/surge voltage suppressor Manual override Body ported L-type plug connector Non-locking push type M-type plug connector External pilot N.C./N.O. Solenoid valve Base mounted With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar) With light/surge voltage suppressor (Non-polar) Push-turn locking slotted type With light/surge voltage suppressor DIN (EN1753 01-803) terminal Conduit terminal Push-turn locking lever type Power...
Open the catalog to page 2Model Selection by Operating Conditions w Solenoid Valve: Manifold Series Applicable stations Note) Manifold base model Base mounted Solenoid valve Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or more.
Open the catalog to page 3Rubber Seal 3 Port/Pilot Poppet Type Body Ported/Single Unit Series VP300/500/700 Note) Only DIN and conduit terminal types are available for AC mode. Refer to the electrical entry for details. Body ported Series 3 5 7 Pilot type Thread type Internal pilot External pilot Standard (0.7 MPa) High-pressure type (1.0 MPa) Without bracket With bracket Standard With power saving circuit (DC only) Note) Be sure to select the power saving circuit type when it is continuously energized for a long time. (Refer to page 1861 for details.) ∗ T type is only available for DC mode. When T is selected, only...
Open the catalog to page 4Pilot Poppet Type Body Ported/Single Unit Low power consumption 1.5 W (DC) Possible to use as either a selector or divider valve Possible to change from N.C. to N.O. • Refer to page 1862 for changing the type of actuation. Possible to use in vacuum applications Up to –100 kPa Specifications Fluid Type of actuation Standard Internal pilot Operating pressure range (MPa) High-pressure type Standard External pilot High-pressure type Operating pressure range (MPa) Pilot pressure range Ambient and fluid temperature (°C) Max. operating frequency (Hz) Manual override Pilot exhaust type Lubrication...
Open the catalog to page 5Series VP300/500/700 Flow Characteristics/Weight Model Port size Note) Values without bracket Application Example (1) Blow-off valve (2) Pressure release valve External pilot External pilot (7) Double-acting cylinder drive (8) Double-acting cylinder drive (Exhaust center) N.O. (R)3 Vacuum releasing air Atmospheric pressure External pilot or micro pressure (6) Single-acting cylinder drive External pilot Construction Body ported Symbol Pilot type Bracket Assembly Part No. Aluminum die-casted Adapter plate Piston Poppet valve Description Bracket (With 2 screws) Aluminum/HNBR Resin Stainless...
Open the catalog to page 6Pilot Poppet Type Body Ported/Single Unit How to Order Pilot Valve Assembly Caution When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit type), or vice versa. Valve model: ∗ Select from the below in accordance with the valve used. 5 G Z Light/surge voltage suppressor Nil Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar) With light/surge voltage suppressor (Non-polar) V211 Pilot valve assembly Note) There is no S...
Open the catalog to page 7Series VP300/500/700 Series VP300/Body Ported/Dimensions Grommet (G) 1/8, 1/4 2(A) port M5 x 0.8 External pilot port (External pilot specification: R) Manual override 20.4 16 57.6 Approx. 300 (Lead wire length) (Indicator light) e betw een p orts) 1/8, 1/4 1(P), 3(R) port Approx. 300 (Lead wire length) DC without light/surge voltage suppressor (Mounting groove for M5 thread) ∗ Refer to page 1857 separately when piping to PE port is required. Approx. 300 (Lead wire length) M-type plug connector (M) Approx. 300 (Lead wire length) L-type plug connector (L) (Indicator light) [ ]: Without...
Open the catalog to page 8Pilot Poppet Type Body Ported/Single Unit Series VP500/Body Ported/Dimensions Grommet (G) 1/4, 3/8 2(A) port 1/8 External pilot port (External pilot specification: R) Approx. 300 (Lead wire length) Manual override (Indicator light) DC without light/surge voltage suppressor Approx. 300 (Lead wire length) (Mounting groove for M5 thread) etwee n port s) 1/4, 3/8 1(P), 3(R) port 123.5 ∗ Refer to page 1857 separately when piping to PE port is required. Approx. 300 (Lead wire length) DIN terminal (D, Y) Applicable cable O.D. ø4.5 to ø7 M-type plug connector (M) Approx. 300 (Lead wire length)...
Open the catalog to page 9Series VP300/500/700 Series VP700/Body Ported/Dimensions Grommet (G) 1/8 External pilot port (External pilot specification: R) 106.8 Approx. 300 (Lead wire length) (Mounting groove for M6 thread) Approx. 300 (Lead wire length) (Indicator light) DC without light/surge voltage suppressor 107.5 ∗ Refer to page 1857 separately when piping to PE port is required. Approx. 300 (Lead wire length) M-type plug connector (M) Approx. 300 (Lead wire length) L-type plug connector (L) (Indicator light) [ ]: Without indicator light Unless otherwise indicated, dimensions are the same as Grommet (G).
Open the catalog to page 10All SMC PNEUMATIC catalogs and technical brochures
-
SYJ300/500/700 Series
62 Pages
-
Vacuum Unit ZK2 Series
60 Pages
-
Air Cylinder CJ2 Series
117 Pages
-
AS-FS Series
36 Pages
-
IDF series
12 Pages
-
MHL2 Series
24 Pages
-
JCM Serie
18 Pages
-
EX245 Series
12 Pages
-
Pin Cylinder CJP2/CDJP2/CJP
19 Pages
-
5 Port Solenoid Valve VQC
63 Pages
-
5 Port Solenoid Valve VQ
79 Pages
-
SY
268 Pages
-
5-p0979-0980-hep500
2 Pages
-
5-p0977-0978-aep100
2 Pages
-
5-p0966-0971-lmu
5 Pages
-
5-p0960-0966-alb900
6 Pages
-
5-p0956-0960-ald600
5 Pages
-
5-p0948-0950-al800
3 Pages
-
es70-44c-vx2
52 Pages
-
es50-37-kq2
124 Pages
-
ex-pcw
23 Pages
-
1-p2124-2152-ex510
29 Pages
-
1-p2111-2122-ex500
12 Pages
-
1-p2063-2073-ex260
11 Pages
-
4-p0147-0178-msu-mds
32 Pages
-
es20-230b-crb2
59 Pages
-
1-p1869-1878-vp3145
10 Pages
-
1-p1789-1829-vqz100
41 Pages
-
1-p1727-1788-syj300
62 Pages
-
5 Port Solenoid Valve S0700
111 Pages
-
5 Port Solenoid Valve VF
59 Pages
-
5 Port Solenoid Valve SV
127 Pages
-
VH
9 Pages
-
CUJ
41 Pages
-
AL
3 Pages
-
kj mm
9 Pages
-
AQ
4 Pages
-
SY3000/5000-X13
2 Pages
-
Series MB
24 Pages
-
Series LES
23 Pages
-
Series LEFB
16 Pages
-
Series PF3W
28 Pages
-
Series IDG?A/IDG
56 Pages
-
Floating Joint
7 Pages
-
Series IZS40/41/42
32 Pages
-
Series LEY
7 Pages
-
Series VHS
12 Pages
-
Series CY1S
28 Pages
-
SeriesCQ2/CQS/CQ
4 Pages
-
In-line Air Filter
12 Pages
-
5 Port Solenoid Valve
60 Pages
-
Series CQ2/CQS
2 Pages
-
AS series
2 Pages
-
corporate guide
13 Pages
-
ZP
69 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
MHZ
68 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
RSK
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
GLJ
65 Pages
-
MGJ
7 Pages
-
Mx
36 Pages
-
MXH
18 Pages
-
My3
56 Pages
-
my1b
20 Pages
-
CC
15 Pages
-
J
14 Pages
-
CQ2
51 Pages
-
standard cylinder
84 Pages
-
VFN
6 Pages
-
SY3000
246 Pages
-
SJ3A6
18 Pages
-
1301/IW
14 Pages
-
CHQ/CHDQ
19 Pages
-
AC
95 Pages
-
HAW
4 Pages
-
HAA
3 Pages
-
ZB
24 Pages
-
CRB2
35 Pages
-
CJ1
5 Pages
-
SYJ
62 Pages
-
SJ
78 Pages