Vacuum Unit Ejector System Vacuum Pump System Air supply is cut-off when vacuum is reached. Energy saving ejector Air consumption 93% reduction Reduced by the pressure switch for vacuum with energy saving function and efficient ejectors (Under SMC’s measurement conditions) More efficient ejector Suction flow (Compared to other SMC 1-stage ejectors) 50% increase Wiring variations D-sub connector Flat ribbon cable connector Individual wiring
Open the catalog to page 1Vacuum Unit ZK2\3A Series Digital pressure switch with energy saving function reduces air consumption by 90%. *1 Under SMC's measurement conditions While the suction signal is ON, the ON/OFF operation of the supply valve is also performed automatically within the set value. More efficient ejector Energy saving ejector Existing product Air is supplied and exhausted intermittently when the vacuum decreases. Air supply j | Air is supplied and exhausted continuously during the adsorption of the workpiece. Air supply^ 1 8 Atmospheric pressure Vacuum pressure Existing ejector Ejector with energy...
Open the catalog to page 2High-noise Reduction Silencer Vacuum Unit ZK2\3A Series Improved low noise and suction flow by adoption of a high-noise reduction silencer Low noise 46 dB (A)*1 *1 Nozzle size: 00.7 (Under SMC's measurement conditions) Nozzle size
Open the catalog to page 3Vacuum Unit ZK2mA Series Piping Wiring Installation time reduced!! Dual 2-port valve (Supply valve/Release valve) M Supply valve: Self-holding∗1 Even if there is a power cut, the vacuum is maintained as long as there is supply air. q he vacuum is maintained during power failure as long as air is supplied. T This can prevent the workpiece from being dropped. w he unit turns on by instantaneous energizing (minimum 20 ms.). Continuous energizing is not necessary. T This can reduce the power consumption. M Linked supply and release valves operation∗1 The self-holding type supply valve will be...
Open the catalog to page 4Vacuum Unit ZK2mA Series Pressure Sensor/Switch Variations M ressure switch for vacuum P with energy saving function Pressure switch for vacuum M Pressure switch for vacuum Set value can be copied up to 10 units. Reduction in setting work/Prevention of mistakes in setting ∗1 opy function is not available for C switches with the pressure switch for vacuum with energy saving function. Mounting (Options) M Single unit bracket mounting M Single unit DIN rail mounting M Manifold DIN rail mounting Mounting bracket for single unit Stopper DIN rail mounting bracket
Open the catalog to page 5Vacuum Unit ZK2mA Series Vacuum Unit Variations Single Unit Variations Ejector System Nozzle size Vacuum switch · Pressure sensor · Pressure switch for vacuum · Pressure switch for vacuum with energy saving function Air pressure supply (PV) port ø6, ø1/4" One-touch fittings Without vacuum switch Vacuum break flow adjusting needle Screwdriver operation type long lock nut∗1 Combination of supply valve and release valve Round lock Silencer exhaust Screwdriver operation type∗3 ∗3 Option Exhaust (EXH) port Port exhaust High-noise reduction silencer exhaust Supply valve N.C N.C Self-holding...
Open the catalog to page 6Vacuum Unit ZK2mA Series Manifold Variations Ejector System Individual wiring D-sub connector Individual port exhaust Manifold stations 1 to 10 stations Complex exhaust∗1 ∗1 he complex exhaust is a combined T exhaust method of the common exhaust from the end plate and the direct exhaust from each station. Wiring type Common air pressure supply (PV) port · D-sub connector · Flat ribbon cable connector · Individual wiring Individual air pressure supply (PV) port∗2 High-noise reduction silencer exhaust · Complex exhaust∗1 · Port exhaust · High-noise reduction silencer exhaust ∗3 When the...
Open the catalog to page 7Vacuum Unit ZK2mA Series Model Selection Guide for the Vacuum Unit ZK2mA Series Valve Without energy With energy How to With valve saving function saving function order Without Pressure sensor/Pressure Pressure switch Supply Release switch for vacuum for vacuum valve valve With valve Single unit Ejector System — Pressure switch for vacuum Without valve With valve Pressure switch for vacuum with energy saving function Pressure switch for vacuum With valve Pressure sensor With valve Pressure sensor Pressure switch for vacuum With valve Pressure switch for vacuum with energy saving function...
Open the catalog to page 8, Single Uni^For M^nfQl^Ejector +1 Without | Valve +1 Without | Energy Saving Function • • • p. 13 BanfQJ p. 14 • Vacuum Pump System [SingieUnMVacuum Pump System + Withl Valve +1 Without | Energy Saving Function • ••• p. 15 [For ManifoljVacuum Pump System + With! Valve +1 Without | Energy Saving Function • •• p. 16 Pressure Sensor/Pressure Switch for Vacuum Specifications, Description (Pressure Switch for Vacuum) • ■ p. 22 Pressure Switch for Vacuum with Energy Saving Function Specifications, Internal Circuit and Wiring Example • ■ p. 23
Open the catalog to page 9Ejector System Vacuum Unit Ejector + WE3 Valve + Iwithoutl Energy Saving Function Q Nominal nozzle size * Refer to page 18 for the standard supply pressure per nozzle diameter. e Combination of supply valve and release valve *2 Supply valve maintains vacuum by energization (20 ms or more). Stopping the vacuum turns on the release valve. (Supply valve/Release valve/Pressure switch for vacuum) r ed voltage (Supply valve/Release valve) *4 For the connector length other than 300 mm, order the connector assembly on page 32 separately. 0 Pressure switch for vacuum/Pressure sensor *3 The unit...
Open the catalog to page 10Ejector System Vacuum Unit Ejector + [2333 Valve + Wh Energy Saving Function w Nominal nozzle size e Combination of supply valve and release valve * Refer to page 18 for the standard supply pressure per nozzle diameter. r Rated voltage (Supply valve/Release valve) t sure switch for vacuum with energy saving function *2 The unit selection function is not available in Japan due to the New Measurement Law. The unit for the type without the unit selection function is fixed as kPa.
Open the catalog to page 11All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages