Vacuum Unit Ejector System Vacuum Pump System Air supply is cut-off when vacuum is reached. Energy saving ejector Air consumption 93% reduction Reduced by the pressure switch for vacuum with energy saving function and efficient ejectors (Under SMC’s measurement conditions) More efficient ejector Suction flow (Compared to other SMC 1-stage ejectors) 50% increase Wiring variations D-sub connector Flat ribbon cable connector Individual wiring

Open the catalog to page 1
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 2

Vacuum Unit ZK2\3A Series Digital pressure switch with energy saving function reduces air consumption by 90%. *1 Under SMC's measurement conditions While the suction signal is ON, the ON/OFF operation of the supply valve is also performed automatically within the set value. More efficient ejector Energy saving ejector Existing product Air is supplied and exhausted intermittently when the vacuum decreases. Air supply j | Air is supplied and exhausted continuously during the adsorption of the workpiece. Air supply^ 1 8 Atmospheric pressure Vacuum pressure Existing ejector Ejector with energy...

Open the catalog to page 2
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 3

High-noise Reduction Silencer Vacuum Unit ZK2\3A Series Improved low noise and suction flow by adoption of a high-noise reduction silencer Low noise 46 dB (A)*1 *1 Nozzle size: 00.7 (Under SMC's measurement conditions) Nozzle size

Open the catalog to page 3
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 4

Vacuum Unit ZK2mA Series Piping Wiring Installation time reduced!! Dual 2-port valve (Supply valve/Release valve) M Supply valve: Self-holding∗1 Even if there is a power cut, the vacuum is maintained as long as there is supply air. q he vacuum is maintained during power failure as long as air is supplied. T This can prevent the workpiece from being dropped. w he unit turns on by instantaneous energizing (minimum 20 ms.). Continuous energizing is not necessary. T This can reduce the power consumption. M Linked supply and release valves operation∗1 The self-holding type supply valve will be...

Open the catalog to page 4
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 5

Vacuum Unit ZK2mA Series Pressure Sensor/Switch Variations M ressure switch for vacuum P with energy saving function Pressure switch for vacuum M Pressure switch for vacuum Set value can be copied up to 10 units. Reduction in setting work/Prevention of mistakes in setting ∗1 opy function is not available for C switches with the pressure switch for vacuum with energy saving function. Mounting (Options) M Single unit bracket mounting M Single unit DIN rail mounting M Manifold DIN rail mounting Mounting bracket for single unit Stopper DIN rail mounting bracket

Open the catalog to page 5
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 6

Vacuum Unit ZK2mA Series Vacuum Unit Variations Single Unit Variations Ejector System Nozzle size Vacuum switch · Pressure sensor · Pressure switch for vacuum · Pressure switch for vacuum with energy saving function Air pressure supply (PV) port ø6, ø1/4" One-touch fittings Without vacuum switch Vacuum break flow adjusting needle Screwdriver operation type long lock nut∗1 Combination of supply valve and release valve Round lock Silencer exhaust Screwdriver operation type∗3 ∗3 Option Exhaust (EXH) port Port exhaust High-noise reduction silencer exhaust Supply valve N.C N.C Self-holding...

Open the catalog to page 6
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 7

Vacuum Unit ZK2mA Series Manifold Variations Ejector System Individual wiring D-sub connector Individual port exhaust Manifold stations 1 to 10 stations Complex exhaust∗1 ∗1 he complex exhaust is a combined T exhaust method of the common exhaust from the end plate and the direct exhaust from each station. Wiring type Common air pressure supply (PV) port · D-sub connector · Flat ribbon cable connector · Individual wiring Individual air pressure supply (PV) port∗2 High-noise reduction silencer exhaust · Complex exhaust∗1 · Port exhaust · High-noise reduction silencer exhaust ∗3 When the...

Open the catalog to page 7
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 8

Vacuum Unit ZK2mA Series Model Selection Guide for the Vacuum Unit ZK2mA Series Valve Without energy With energy How to With valve saving function saving function order Without Pressure sensor/Pressure Pressure switch Supply Release switch for vacuum for vacuum valve valve With valve Single unit Ejector System — Pressure switch for vacuum Without valve With valve Pressure switch for vacuum with energy saving function Pressure switch for vacuum With valve Pressure sensor With valve Pressure sensor Pressure switch for vacuum With valve Pressure switch for vacuum with energy saving function...

Open the catalog to page 8
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 9

, Single Uni^For M^nfQl^Ejector +1 Without | Valve +1 Without | Energy Saving Function • • • p. 13 BanfQJ p. 14 • Vacuum Pump System [SingieUnMVacuum Pump System + Withl Valve +1 Without | Energy Saving Function • ••• p. 15 [For ManifoljVacuum Pump System + With! Valve +1 Without | Energy Saving Function • •• p. 16 Pressure Sensor/Pressure Switch for Vacuum Specifications, Description (Pressure Switch for Vacuum) • ■ p. 22 Pressure Switch for Vacuum with Energy Saving Function Specifications, Internal Circuit and Wiring Example • ■ p. 23

Open the catalog to page 9
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 10

Ejector System Vacuum Unit Ejector + WE3 Valve + Iwithoutl Energy Saving Function Q Nominal nozzle size * Refer to page 18 for the standard supply pressure per nozzle diameter. e Combination of supply valve and release valve *2 Supply valve maintains vacuum by energization (20 ms or more). Stopping the vacuum turns on the release valve. (Supply valve/Release valve/Pressure switch for vacuum) r ed voltage (Supply valve/Release valve) *4 For the connector length other than 300 mm, order the connector assembly on page 32 separately. 0 Pressure switch for vacuum/Pressure sensor *3 The unit...

Open the catalog to page 10
ZK2-A Series - Vacuum Unit Generator System and Vacuum Pump System - 11

Ejector System Vacuum Unit Ejector + [2333 Valve + Wh Energy Saving Function w Nominal nozzle size e Combination of supply valve and release valve * Refer to page 18 for the standard supply pressure per nozzle diameter. r Rated voltage (Supply valve/Release valve) t sure switch for vacuum with energy saving function *2 The unit selection function is not available in Japan due to the New Measurement Law. The unit for the type without the unit selection function is fixed as kPa.

Open the catalog to page 11

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. HRS series

    47 Pages

  48. LES

    59 Pages

  49. MHS

    74 Pages

  50. MHY

    27 Pages

  51. MHC

    27 Pages

  52. MHR

    30 Pages

  53. MHZ series

    78 Pages

  54. MSQ

    37 Pages

  55. MGP

    127 Pages

  56. MXS

    38 Pages

  57. NRB

    10 Pages

  58. MXW

    22 Pages

  59. MHT

    11 Pages

  60. MY3

    54 Pages

  61. CQM

    15 Pages

  62. NCA1

    63 Pages

  63. CM2

    152 Pages

  64. NCM

    91 Pages

  65. NCG

    96 Pages

  66. NCRA1

    5 Pages

  67. CS2

    32 Pages

  68. T/TIA

    1 Pages

  69. KR

    7 Pages

  70. KF

    16 Pages

  71. KQ

    80 Pages

  72. AFF

    80 Pages

  73. AMG

    80 Pages

  74. IDF

    16 Pages

  75. HAA

    3 Pages

  76. ZFA

    14 Pages

  77. ZA

    13 Pages

  78. MHF

    32 Pages

  79. CRB

    44 Pages

  80. D

    117 Pages

  81. RB

    23 Pages

  82. CEP

    44 Pages

  83. rsq

    30 Pages

  84. CLK

    51 Pages

  85. MK

    20 Pages

  86. CLJ

    65 Pages

  87. MGJ

    7 Pages

  88. ZSE30A

    17 Pages

  89. IDFB*E

    89 Pages

  90. ISE10

    16 Pages

  91. ITV1000/2000

    50 Pages

  92. AW

    27 Pages

  93. NVFM200

    12 Pages

  94. NVM100

    32 Pages

  95. LLA*A

    36 Pages

  96. VX3*

    41 Pages

  97. SY3000

    158 Pages

  98. CH(D)2

    175 Pages

  99. LEHZ

    82 Pages

  100. M(D)SUB

    31 Pages

  101. CXSJ

    58 Pages

  102. CY3B

    39 Pages

  103. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages