Vacuum Unit Ejector System Vacuum Pump System Air supply is cut-off when vacuum is reached. Energy saving ejector Air consumption 93% reduction Reduced by the pressure switch for vacuum with energy saving function and efficient ejectors (Under SMC’s measurement conditions) More efficient ejector Suction flow (Compared to other SMC 1-stage ejectors) 50% increase Wiring variations D-sub connector Flat ribbon cable connector Individual wiring
Open the catalog to page 1Vacuum Unit ZK2\3A Series Digital pressure switch with energy saving function reduces air consumption by 90%. *1 Under SMC's measurement conditions While the suction signal is ON, the ON/OFF operation of the supply valve is also performed automatically within the set value. More efficient ejector Energy saving ejector Existing product Air is supplied and exhausted intermittently when the vacuum decreases. Air supply j | Air is supplied and exhausted continuously during the adsorption of the workpiece. Air supply^ 1 8 Atmospheric pressure Vacuum pressure Existing ejector Ejector with energy saving...
Open the catalog to page 2High-noise Reduction Silencer Vacuum Unit ZK2\3A Series Improved low noise and suction flow by adoption of a high-noise reduction silencer Low noise 46 dB (A)*1 *1 Nozzle size: 00.7 (Under SMC's measurement conditions) Nozzle size
Open the catalog to page 3Vacuum Unit ZK2mA Series Piping Wiring Installation time reduced!! Dual 2-port valve (Supply valve/Release valve) M Supply valve: Self-holding∗1 Even if there is a power cut, the vacuum is maintained as long as there is supply air. q he vacuum is maintained during power failure as long as air is supplied. T This can prevent the workpiece from being dropped. w he unit turns on by instantaneous energizing (minimum 20 ms.). Continuous energizing is not necessary. T This can reduce the power consumption. M Linked supply and release valves operation∗1 The self-holding type supply valve will be turned...
Open the catalog to page 4Vacuum Unit ZK2mA Series Pressure Sensor/Switch Variations M ressure switch for vacuum P with energy saving function Pressure switch for vacuum M Pressure switch for vacuum Set value can be copied up to 10 units. Reduction in setting work/Prevention of mistakes in setting ∗1 opy function is not available for C switches with the pressure switch for vacuum with energy saving function. Mounting (Options) M Single unit bracket mounting M Single unit DIN rail mounting M Manifold DIN rail mounting Mounting bracket for single unit Stopper DIN rail mounting bracket
Open the catalog to page 5Vacuum Unit ZK2mA Series Vacuum Unit Variations Single Unit Variations Ejector System Nozzle size Vacuum switch · Pressure sensor · Pressure switch for vacuum · Pressure switch for vacuum with energy saving function Air pressure supply (PV) port ø6, ø1/4" One-touch fittings Without vacuum switch Vacuum break flow adjusting needle Screwdriver operation type long lock nut∗1 Combination of supply valve and release valve Round lock Silencer exhaust Screwdriver operation type∗3 ∗3 Option Exhaust (EXH) port Port exhaust High-noise reduction silencer exhaust Supply valve N.C N.C Self-holding release...
Open the catalog to page 6Vacuum Unit ZK2mA Series Manifold Variations Ejector System Individual wiring D-sub connector Individual port exhaust Manifold stations 1 to 10 stations Complex exhaust∗1 ∗1 he complex exhaust is a combined T exhaust method of the common exhaust from the end plate and the direct exhaust from each station. Wiring type Common air pressure supply (PV) port · D-sub connector · Flat ribbon cable connector · Individual wiring Individual air pressure supply (PV) port∗2 High-noise reduction silencer exhaust · Complex exhaust∗1 · Port exhaust · High-noise reduction silencer exhaust ∗3 When the ejector...
Open the catalog to page 7Vacuum Unit ZK2mA Series Model Selection Guide for the Vacuum Unit ZK2mA Series Valve Without energy With energy How to With valve saving function saving function order Without Pressure sensor/Pressure Pressure switch Supply Release switch for vacuum for vacuum valve valve With valve Single unit Ejector System — Pressure switch for vacuum Without valve With valve Pressure switch for vacuum with energy saving function Pressure switch for vacuum With valve Pressure sensor With valve Pressure sensor Pressure switch for vacuum With valve Pressure switch for vacuum with energy saving function Without...
Open the catalog to page 8, Single Uni^For M^nfQl^Ejector +1 Without | Valve +1 Without | Energy Saving Function • • • p. 13 BanfQJ p. 14 • Vacuum Pump System [SingieUnMVacuum Pump System + Withl Valve +1 Without | Energy Saving Function • ••• p. 15 [For ManifoljVacuum Pump System + With! Valve +1 Without | Energy Saving Function • •• p. 16 Pressure Sensor/Pressure Switch for Vacuum Specifications, Description (Pressure Switch for Vacuum) • ■ p. 22 Pressure Switch for Vacuum with Energy Saving Function Specifications, Internal Circuit and Wiring Example • ■ p. 23
Open the catalog to page 9Ejector System Vacuum Unit Ejector + WE3 Valve + Iwithoutl Energy Saving Function Q Nominal nozzle size * Refer to page 18 for the standard supply pressure per nozzle diameter. e Combination of supply valve and release valve *2 Supply valve maintains vacuum by energization (20 ms or more). Stopping the vacuum turns on the release valve. (Supply valve/Release valve/Pressure switch for vacuum) r ed voltage (Supply valve/Release valve) *4 For the connector length other than 300 mm, order the connector assembly on page 32 separately. 0 Pressure switch for vacuum/Pressure sensor *3 The unit selection...
Open the catalog to page 10Ejector System Vacuum Unit Ejector + [2333 Valve + Wh Energy Saving Function w Nominal nozzle size e Combination of supply valve and release valve * Refer to page 18 for the standard supply pressure per nozzle diameter. r Rated voltage (Supply valve/Release valve) t sure switch for vacuum with energy saving function *2 The unit selection function is not available in Japan due to the New Measurement Law. The unit for the type without the unit selection function is fixed as kPa.
Open the catalog to page 1167 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages