video corpo
cad

VX3*
1 /41Pages

VX3*

VX3*
1 /41Pages

Catalog excerpts

VX3*-1

CAT.ES70-26 B Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption (DC specification) 4.5 4. W 8 W→ 7 W 10.5 W 0.5 11.5 W → 10. 1.5 6 W→ New VX 3 Series VX31/32 /33

 Open the catalog to page 1
VX3*-2

Solenoid valves for various fluids used in a wide variety of Direct Operated 3 Port Solenoid Valve Flame resistant mold coil material Maintenance is performed easily For Air, Water, Oil, Steam mm Series VX31/32/33 Normally Closed (N.C.) / Normally Open (N.O.) / Common (COM.) Manifold: Normally Closed (N.C.) / Normally Open (N.O.) / Common (COM.)

 Open the catalog to page 2
VX3*-3

Direct Operated 2 Port Pilot Operated 2 Port For Air, Vacuum, Water, Steam, Oil Valve type Port size Pilot Operated 2 Port Valve type Port size 2 Port for Dust Collector (Solenoid type, Air Operated type) Valve type Port size 0ri^dia- Water Hammer Relief, Pilot Operated 2 Port Valve type Port size 0ritÎ!iJia- Pilot Operated 2 Port for Zero Differential Pressure Valve type Port size mm0 Pilot Operated 2 Port for High Pressure Valve type Port size

 Open the catalog to page 3
VX3*-4

Direct Operated 3 Port Solenoid Valve Single Unit Solenoid Coil Coil: Class B, Class H Rated Voltage Body — C37, Stainless steel Seal — NBR, FKM, EPDM, PTFE, FFKM Electrical Entry • Conduit terminal Base — Aluminum Electrical Entry Common SUP/EXH type • Conduit terminal Solenoid Coil Coil: Class B, Class H Rated Voltage

 Open the catalog to page 4
VX3*-5

Standard Specifications * Electrical entry, Grommet with surge voltage suppressor (GS) has a rating of IP40. Solenoid Coil Specifications Note) The values are for an ambient temperature of 20°C and at the rated voltage. AC Specification (Class B coil, Built-in full-wave rectifier type) * There Is no difference In the frequency and the Inrush and energized apparent power, since a rectifying circuit Is used In the AC (Class B). Note) The values are for an ambient temperature of 20°C and at the rated voltage. AC Specification (Class H coil) Note) The values are for an ambient temperature of 20°C...

 Open the catalog to page 5
VX3*-6

Applicable Fluid Check List All Options (Single Unit) • If using for other fluids, please consult with SMC. • Option symbol * Aluminum is only available with the material for a manifold base. * If using for other fluids, please consult with SMC. Note 1)The leakage amount (10~e Pa-m3/s) of "V", "M" options are values when differential pressure is 0.1 MPa. Note 2) "V", "M" and "K" options are for oil-free treatment. Note 3) The dynamic viscosity of the fluid must not exceed 50 mm2/s or less. Note 4) Coil insulation type Class H: AC spec, only, Class B/AC spec: built-in full-wave rectifier type...

 Open the catalog to page 6
VX3*-7

EHEQ/Single Unit (Inert gas, Non-leak, Medium vacuum) Model / Valve Specifications_ Passage symbol Passage symbol Passage symbol Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively. Also, add 60 g for VX31 □□, 80 g for VX32DD and VX33DD respectively for bracket option. Refer to "Glossary" on page 31, for details on the max. operating pressure differential and the max. system pressure. Fluid and Ambient Temperature Note) Dew point temperature: -10°C or less Valve Leakage Internal Leakage / External Leakage Note) The leakage...

 Open the catalog to page 7
VX3*-8

Direct Operated 3 Port Solenoid Valve How to Order (Single Unit) AC/Class B coil (Built-in full-wave rectifier type) Refer to Table (1 ) shown Valve / Body type < Orifice diameter Refer to Table (1 ) shown Solenoid valve option Refer to Table (2) shown Refer to Table (1) shown below for availability. Rated voltage Built-in full-wave rectifier type Electrical entry (AC/DC) • Refer to Table (3) shown below for availability. Refer to page 23 for ordering coil only. GS-With grommet surge voltage suppressor T -With conduit terminal TS -With conduit terminal and surge voltage suppressor TL -With conduit...

 Open the catalog to page 8
VX3*-9

(Inert gas, Non-leak, Medium vacuum) Solenoid Valve for Manifold / Valve Specifications Passage symbol Passage symbol Passage symbol > Refer to "Glossary" on page 31 for details on the max. operating pressure differential and the max. system pressure. Fluid and Ambient Temperature Valve Leakage Internal Leakage / External Leakage *\ Note) The leakage amount (10 * Pa-m7sec) for the "V" option are values .Jj when the differential pressure Is 0.1 MPa.

 Open the catalog to page 9
VX3*-10

Direct Operated 3 Port Solenoid Valve How to Order (Solenoid Valve for Manifold) AC/Class B coil (Built-in full-wave rectifier type) Refer to Table (1 ) shown Valve / Body type ' Orifice diameter Refer to Table (1 ) shown Solenoid valve option Refer to Table (2) shown * Refer to Table (3) shown below for availability. Refer to page 23 for ordering coil only. How to Order Manifold Bases Port size (Individual port) * Common port sizes are all Rc 1/4. * Indicating numbers shown below are Manifold base • Blanking plate part no. Seal material How to Order Manifold Assemblies (Example) Enter the valve...

 Open the catalog to page 10
VX3*-11

Model / Valve Specifications Passage symbol Passage symbol Passage symbol Fluid and Ambient Temperature Valve Leakage Internal Leakage / External Leakage Note) With no freezing

 Open the catalog to page 11
VX3*-12

Direct Operated 3 Port Solenoid Valve How to Order (Single Unit) For Water / Single Unit AC/Class B coil (Built-in full-wave rectifier type) Refer to Table (1 ) shown Orifice diameter Refer to Table (1 ) shown Valve / Body type « Solenoid valve option Refer to Table (2) shown Refer to Table (1 ) shown Thread type •- Rated voltage rectifier type Electrical entry * Peter to Table (3) shown below for availability Refer to page 23 for ordering coil only. GS-With grommet surge voltage suppressor T -With conduit terminal TS -With conduit terminal and surge voltage suppressor TL -With conduit terminal...

 Open the catalog to page 12
VX3*-13

ÍCTgfl/Single Unit Model / Valve Specifications Passage symbol Passage symbol Passage symbo > Refer to "Glossary" on page 31 for details on the max. operating pressure differential anc the max. systerr pressure Fluid and Ambient Temperature Note) Dynamic viscosity: 50 mm2/s or less Valve Leakage Internal Leakage / External Leakage

 Open the catalog to page 13

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. SY3000

    158  Pages

  101. CH(D)2

    175  Pages

  102. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.