SX series - 1

5 Port Solenoid Valve Rubber Seal Pilot valves are concentrated on one-side, realizing wiring into a bundle and Compact design with large flow Response time 10 ms (Representative value) High reliability and long service life exceeding 50 million cycles or more (The valve may differ from a life under actual operating conditions. It is derived from our life test data.) Improved drainage resistance copper-free applications No exhaust mist, no exhaust noise <Common exhaust type for main and pilot valve> Bright color tone and state The fittings of the cylinder ports can be changed simply for the modification of the port size or for replacement. <Body ported> Indicator light and manual Same manifold base as Series SY The characteristic values shown in the catalog are representative values, not warranting the performance.

Open the catalog to page 1
SX series - 2

Cylinder Speed Chart Body Ported Please confirm the actual conditions with SMC Sizing Program. Bore size — upward actuation * It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being * The average velocity of the cylinder is what the stroke is divided by the total stroke time. * Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Base Mounted (With sub-plate) Bore size upward actuation It is when the cylinder is extending that is meter-out controlled by speed controller which is...

Open the catalog to page 2
SX series - 3

Cylinder Speed Chart Conditions [When using SGP (Steel pipe)]

Open the catalog to page 3
SX series - 6

Manifold Variations Bar stock type Body Ported Individual wiring í Direct piping to the main unit of a valve. Combinations of different fittings are possible. 20 Type P. 1-6-42 SX320 SX520 SX720 Bar stock type Flat ribbon cable í A 26 pins MIL connector permits onehand wiring of external cables in a bundle. 20 P Type N P. 1-6-48 SX320 SX520 SX720 Compact bar stock type Individual wiring í The base mounting facilitates maintenance after valves are changed. Compact bar stock type Flat cable í A 26 pins MIL connector permits one-touch wiring of external cables in a bundle. Bar stock...

Open the catalog to page 6
SX series - 8

Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 1-7-2. Manual Override Operation ■ Non-locking push type Manual override for solenoid B Manual override for solenoid A Push-turn locking slotted type (Type D) After pushing down, turn in the direction of the arrow. If you do not turn, the mechanism is the same as that of a non-locking push type. Manual override for solenoid B Manual override for solenoid A When locking the manual override on the push-turn locking slotted type, be sure to push it down before turning. Turning without first...

Open the catalog to page 8
SX series - 9

Common Connector Assembly for Manifold Caution With the common connector assembly all of the common lead wires are tied together and this reduces wiring time. Common connector assembly part numbers Positive common specifications Negative common specifications For single solenoid For single solenoid SX100-42-4S SX100-43-4S Common Connector Assembly Wiring When only common connector assembly is ordered, wiring should be done as shown in How to Order Common Connector Assembly the illustration to the right. Refer to “How to Use Plug Connector” on page 1-6-8 for further information on socket...

Open the catalog to page 9
SX series - 10

Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 1-7-2. Light/Surge Voltage Suppressor Single solenoid Light/Surge voltage suppressor prevent reverse current Single solenoid Light/Surge voltage suppressor prevent reverse current Surge voltage suppressor Surge voltage suppressor prevent reverse current Double solenoid, 3 position type Light/Surge voltage suppressor prevent reverse current Double solenoid, 3 position type Light/Surge voltage suppressor Diode to prevent reverse current Surge voltage suppressor Surge voltage suppressor Diode...

Open the catalog to page 10
SX series - 12

I For details about certified products conforming to international standards, Body Ported Valve Single Unit 3 position closed center 3 position exhaust center 3 position pressure center Rated voltage Common specifications Positive common Negative common Manual override slotted type Light/Surge voltage Lead wire length Lead wire length With lead wire With lead wire Without lead wire Without lead wire without connector Without connector H * The LN or MN option includes 2 sockets for single solenoid ■v valves and 3 sockets for double solenoid valves. F1: With foot bracket F2: With side bracket...

Open the catalog to page 12
SX series - 13

Body Ported L^r-I Made to Order Specifications I ff^ I (For details, refer to pages Mote) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the...

Open the catalog to page 13
SX series - 14

Body Ported Flow Characteristics/Weight Note) [ ]: Denotes normal position. Note) [ ]: Denotes normal position.

Open the catalog to page 14
SX series - 15

Body Ported Note) [ ]: Denotes normal position.

Open the catalog to page 15
SX series - 16

Body Ported Connector Assembly Positive common specifications Negative common specifications For double solenoid, evinn /M /in Lead wire length For detailed information on connector assembly, refer to page 1-6-8. 3 position closed center/exhaust center/pressure center 3 position closed center 3 position exhaust center 3 position pressure center (This figure shows a closed center type Component Parts

Open the catalog to page 16
SX series - 17

Body Ported Series SX3000/5000/7000 How to Change Port Block Assembly The cylinder port block assembly can easily be changed. When changing block assembly, correct screw torque must be achieved. Cut off the air supply to confirm that no air is left in the manifold before starting operation. Remaining air or inappropriate installation may cause an accident. Ȝ For SX5000 Port block assembly Port block assembly (Cassette type) (Thread type) SV Fittings assembly SZ Mounting screw SY SYJ SX Caution Mounting screw tightening torques SX3000(M2): 0.17 N·m SX 5 000(M3): 0.8 N·m 7 ∗ Refer to “How to...

Open the catalog to page 17

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. HRS series

    47 Pages

  48. LES

    59 Pages

  49. MHS

    74 Pages

  50. MHY

    27 Pages

  51. MHC

    27 Pages

  52. MHR

    30 Pages

  53. MHZ series

    78 Pages

  54. MSQ

    37 Pages

  55. MGP

    127 Pages

  56. MXS

    38 Pages

  57. NRB

    10 Pages

  58. MXW

    22 Pages

  59. MHT

    11 Pages

  60. MY3

    54 Pages

  61. CQM

    15 Pages

  62. NCA1

    63 Pages

  63. CM2

    152 Pages

  64. NCM

    91 Pages

  65. NCG

    96 Pages

  66. NCRA1

    5 Pages

  67. CS2

    32 Pages

  68. T/TIA

    1 Pages

  69. KR

    7 Pages

  70. KF

    16 Pages

  71. KQ

    80 Pages

  72. AFF

    80 Pages

  73. AMG

    80 Pages

  74. IDF

    16 Pages

  75. HAA

    3 Pages

  76. ZFA

    14 Pages

  77. ZA

    13 Pages

  78. MHF

    32 Pages

  79. CRB

    44 Pages

  80. D

    117 Pages

  81. RB

    23 Pages

  82. CEP

    44 Pages

  83. rsq

    30 Pages

  84. CLK

    51 Pages

  85. MK

    20 Pages

  86. CLJ

    65 Pages

  87. MGJ

    7 Pages

  88. ZSE30A

    17 Pages

  89. IDFB*E

    89 Pages

  90. ISE10

    16 Pages

  91. ITV1000/2000

    50 Pages

  92. AW

    27 Pages

  93. NVFM200

    12 Pages

  94. NVM100

    32 Pages

  95. LLA*A

    36 Pages

  96. VX3*

    41 Pages

  97. SY3000

    158 Pages

  98. CH(D)2

    175 Pages

  99. LEHZ

    82 Pages

  100. M(D)SUB

    31 Pages

  101. CXSJ

    58 Pages

  102. CY3B

    39 Pages

  103. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. ACG series

    25 Pages

  4. Shock Absorber

    16 Pages

  5. Silencer

    4 Pages