1. Catalogs
  2. SMC Corporation of America
  3. Self-seal Fittings Catalog
video corpo
cad

Self-seal Fittings Catalog
1 /13Pages

Self-seal Fittings Catalog

Self-seal Fittings Catalog
1 /13Pages

Catalog excerpts

Self-seal Fittings Catalog-1

Air does not exhaust after removal of tubing. > The body and the threaded portion can rotate.Pipe tape is not necessary. > Tubing materialTubing O.D.Nylon, Soft nylon, Polyurethane4, 6, 踸8, 10, 12 > FluidAir1.0 MPa3.0 MPa踖5 to 60 Proof pressureAmbient and fluid temperatureThreadThread seal (Standard)Copper-free (Standard) C (No freezing)JIS B 0203 (Taper thread for piping)Mounting sectionNut sectionWith thread sealJIS B 0211 Class 2 (Metric fine thread)Brass parts are all electroless nickel plated Maximum operating pressure > BodyC3604BD, PBTC3604BD (Thread portion)Stainless steel 304Stainless steel 304, POMPOMNBRStudChuck, Spring Guide Collet, Release buttonPOM Valve, RetainerC3604BD, POM StopperSeal, O-ring >

 Open the catalog to page 1
Self-seal Fittings Catalog-2

Male connector Straight union KCH P. 69 KCH P. 60 Use to pipe in the same direction from female thread.Use to pipe at right angles to female thread.Use to connect tubes in both 90 Male elbow Straight plug for frequent use It can save tube cutting labor in the case of frequent tube installation and removal. Use to connect a self- seal fitting and a tube in the same dierection. KCL P. 69 KCH P. 60 > Union tee directions.Use to branch line in the same direction. 2 branched ports has a self-seal function.Use to add the self-seal mechanism to the usual One-touch fittings, Series KQ.Use to connect...

 Open the catalog to page 2
Self-seal Fittings Catalog-3

1. First, tighten it by hand, then give it an additional 1/6 turn with the wrench. Excessive tightening may damage the threaded portion or deform the gasket to cause air leakage. Insufficient tightening may leave the thread loosened or cause air leakage. > 1. When inserting/removing the tubing is difficult under a pressurized condition, it should be inserted or removed by lowering the pressure or after fully exhausting. > Cut the tube perpendicularly, taking care not to damage the outside surface. (Use tube cutter TK-1, 2 or 3. Do not cut the tube with cutting pliers, nippers, scissors, etc.)...

 Open the catalog to page 3
Self-seal Fittings Catalog-7

These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger" . To ensure safety, be sure to observe ISO 4414 > Note 1) , JIS B 8370 > Note 2) and other safety practices. > Operator error could result in injury or equipment damage. Operator error could result in serious injury or loss of life. In extreme conditions, there is a possible result of serious injury or loss of life. Note 1)ISO 4414: Pneumatic fluid power--General rules relating to systems.Note 2)JIS...

 Open the catalog to page 7
Self-seal Fittings Catalog-8

If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break down or malfunction. 1. Confirm the specifications. > Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated. Do not use the product outside their design parameters. Please contact SMC when using the products in applications other than compressed air (including vacuum). 1.Do not use in environments where the product is directly exposed to corrosive gases, chemicals, salt water, water or...

 Open the catalog to page 8
Self-seal Fittings Catalog-10

CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied.It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and components are exported to the member Nations of the EU. Once A manufacturer himselfӔ declares a product to be safe by means of CE marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. CE Mark SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in accordance with CETOP...

 Open the catalog to page 10
Self-seal Fittings Catalog-11

Mark of compliance for CSAMark of compliance for CSA/UL > TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE StandardWith CE symbol for simple visual recognition CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting...

 Open the catalog to page 11
Self-seal Fittings Catalog-12

SMC Pneumatics (U.K.) Ltd. 9 08-563888 FAX: 01 9 08-561185GERMANY Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K. TEL: 01 SMC Pneumatik GmbH Boschring 13-15 D-6332 9 Egelsbach, GermanyTEL: 06103-4020 FAX: 06103-40213 9 ITALY SMC Italia S.p.A. 9 271365 FAX: 02- 9 271365FRANCE Via Garibaldi 62 I-20061 Carugate Milano, Italy TEL: 02- SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 FranceTEL: 01-64-76-10-00 FAX: 01-64-76-10-10SWEDEN SMC Pneumatics Sweden AB EkhagsvҤgen 2 9 -31, S-141 05 Huddinge, Sweden...

 Open the catalog to page 12
Self-seal Fittings Catalog-13

FINLAND 9 -85 SMC Pneumatics Finland OY 9 5-80 FAX: 0 9 -85 9 5-85 9 5NORWAY AUSTRALIA 9 354-8222 FAX: 02- SMC Pneumatics (Australia) Pty.Ltd. 9 8 9 4-571 9 PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 0 SMC Pneumatics Norway A/S 9 0-20 FAX: 67-12- 9 0-21BELGIUM (Distributor) 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02- NEW ZEALAND 9 -573-7007 FAX: 0 SMC Pneumatics (New Zealand) Ltd. 9 -573-7002TAIWAN Vollsveien 13C, Granfoss NҦringspark N-1366 LYSAKER, Norway TEL: 67-12- SMC Pneumatics N.V./S.A. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 0 SMC Pneumatics...

 Open the catalog to page 13

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. VX3*

    41  Pages

  101. SY3000

    158  Pages

  102. CH(D)2

    175  Pages

  103. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.