High Purity Chemical Valve Series LVC/LVA/LVH Integral Fittings/Threaded Ports/Manual Operation (Integral Fittings/Threaded Ports) LVC Air Operated Type Integral Fittings Series LVC P.461 b N.C./N.O. with same configuration/Double acting b Compatible with 100°C fluid temperature LVA LVH LVD LVQ LQ1 a riiall:: ma e r y matte od Bod y B A F New P New LVN TL/TIL LQ3 Series LVC Air Operated Type Threaded Ports Series LVA P.471 b Diaphragm material PTFE, EPR, NBR are selectable teriiall:: er a dy ma t dy ma Bo Bo A/ FA ew New P steel / N Series LVA s Stainles S PP Manual Operation Series LVH Integral fitting type/Threaded type P.481 b Locking and non-locking types available : er al : atteriia l dy ma ody m Bo B A/ / ss steel Stainle PS P F New P New Series LVH 457
Open the catalog to page 1Stable Sealing Surface Guide ring A unique guide ring on the piston rod eliminates lateral motion of the poppet, greatly increasing seal life and reducing particle formation with a stable work surface. Low particle generation Piston bumper Prevents Micro-Bubbles A bumper absorbs piston momentum to minimize impact-induced particles. Diaphragm (PTFE) Special diaphragm construction ensures gentle opening and closing that prevents the formation of micro-bubbles. Back-pressure resistance and long life Buffer Minimal dead space The diaphragm is supported by a buffer that minimizes deformation, which...
Open the catalog to page 2High Purity Chemical Valve Series Integral Fitting Type Series LVC ►►►►►►►►►►►►►►►►►►►►►►►►►►►►P.461 Threaded Type Series LVA 471 With flow rate With bypass With flow rate With indicators Note 1) Refer to the page 471 for the ap- plicable optional body materials. Note 2) Only PFA is applicable as a body
Open the catalog to page 3Manually Operated Series LVH►►►►►►►►►►►►►►►►►►►►►► P.481 Integral Fitting Type_ Threaded Type
Open the catalog to page 4Integral Fitting Type (Hyper Fittings) How to Order Valves (Single Type) Body classi Valve type Note) Refer to variations in valve type combina- Applicable tubing size < Port B (OUT) different dia. size O Basic size # With reducer Note) Applicable fittings for body class 6 Note) Refer to "Variations" in the table below for option combinations. Options can not be combined each other. Pilot port thread type Basic type With flow With flow BfflA Bf^A
Open the catalog to page 5Standard Specifications Note 1 ) Contact SMC if the valve is to be used with vacuum and B -> A flow. Different Diameter Tubing Applicable with Reducer Different diameter tubing can be selected (within a body class) by using a nut and insert bushing (reducer). # w¡tn reduœr Note) Referto page 489 for information on changing tubing sizes. ASpecific Product Precautions , Be sure to read before handling. Refer to front matters 42 and 43 for , i Safety Instructions, and pages 491 and 492 for High Purity Chemical i Connect tubing with special Refer to the pamphlet "High-Purity Fluoropolymer Fittings...
Open the catalog to page 6Integral Fitting Type (Hyper Fittings) SOMOS Suck Back A change of volume inside the suck back valve pulls in liq- uid at the end of the nozzle to prevent dripping. Single type Unit type Adjustment knob knob position. Adjustment knob knob position. Adjustment knob Adjusts the flow rate. knob position. Suck back body Standard Specifications . Note 1) Different diameter tubing shown in ( ) can be selected when used J) with a reducer. Refer to page 489 for details. Body class Valve type 3 Suck back valve Body type Applicable tubing size í Basic size O With reducer With flow rate adjustment The flow...
Open the catalog to page 7Standard type Double acting type With reducer With flow rate adjustment With bypass Parts list Suck back (single type) Actuator section Insert bushing Flow rate adjuster section Suck back (unit type) With indicator
Open the catalog to page 8Integral Fitting Type (Hyper Fittings) Basic type Sensor (Breathing port) R
Open the catalog to page 9With flow rate adjustment With bypass With flow rate adjustment & bypass With indicator Suck back (Single type) Suck back (Unit type)
Open the catalog to page 10Manifold Specifications Note 1) Contact SMC if the manifold will be used with vacuum and A -> P flow. How to Order Manifold Base Body class Base type Stacking type Manifold stations Tubing size for P port and L side connection 1 Tubing size for P port and R side connection Stacking type for manifold Note) Options can not be combined )) each other. » Pilot port thread type
Open the catalog to page 11How to Order Manifold Assembly (Example) Enter the part number of the valves to be mounted together with the manifold base part number. from station 1 on the left ~I~Add the * symbol at the beginning of part numbers for Enter together in order counting from station 1 on the left side, with the A (OUT) ports in front. Manifold variations With flow rate
Open the catalog to page 12Standard Specifications Valve type Applicable tubing size O Basic size # With reducer
Open the catalog to page 13Threaded Type How to Order Valves (Single Type) Body class Note) Refer to "Variations" Thread type Note) Refer to "Variations" in the table be- can not be combined each other. Note) Refer to the "Material" table for the applicable optional body materials.
Open the catalog to page 15Standard Specifications Basic type With flow rate adjustment Note 1) 0 to 60°C when the diaphragm is NBR or EPR. Note 3) Contact SMC if the valve will be used with vacuum and B - ASpecific Product Precautions , Be sure to read before handling. Refer to front matters 42 and 43 for , i Safety Instructions, and pages 491 and 492 for High Purity Chemical 1 1. Avoid using metal fittings with a resin body (taper threads). This can cause damage to the valve body. ■ With flow rate adjustment Adjusts the flow rate by controlling the diaphragm stroke.
Open the catalog to page 16Threaded Type Series L VM Standard type With flow rate adjustment With indicator Double acting type Parts list
Open the catalog to page 17Sensor (Breathing port) R With flow rate With indicator
Open the catalog to page 18With flow rate adjustment With indicator
Open the catalog to page 19Basic type Sensor (Breathing port) U With flow rate With indicator
Open the catalog to page 20Manifold Specifications Note 1) Contact SMC if the manifold will be used with vacuum and A -> P flow. How to Order Manifold Base Base type Stacking type Manifold stations Thread type Port size (port P) Body type Stacking type for manifold Port size (port A) Note) Options can not be combined Thread type
Open the catalog to page 2167 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages