JLV20/30-1

High Purity Air Operated Chemical Liquid Valve Suppresses the generation of particles and reduced footprint! Impact energy when the valve is closed (Proportional to V2) Valve closing speed [V] Existing model Flare type LQ3 Series Fully open Fully closed M he special structure allows for reduced impact when the T valve is closed as well as particle generation suppression. Exhaust air Special construction Special construction The special structure optimizes pilot air exhaust and reduces the valve closing speed just before the poppet hits the orifice. M ariations V Body class Valve type Orifice diameter

 Open the catalog to page 1
JLV20/30-2

High Purity Air Operated Chemical Liquid Valve JLV20/30 Series Chemical-resistant materials are used. With indicator Visual confirmation of the valve open/close status Valve open Actuator section PVDF Poppet PTFE Hyper fittings Flare type LQ3 Series PVDF · Flare type collet construction · Triple-seal construction Valve width Mounting pitch Overall length A Valve width Mounting pitch Overall length A Mounting pitch Existing model Valve width M Applicable for applications requiring high pressure/high back pressure Expanded and standardized operating pressure/back pressure range Operating pressure:...

 Open the catalog to page 2
JLV20/30-3

High Purity Air Operated Chemical Liquid Valve JLV 2 0 Z 07 Body class Symbol Pilot port thread type Symbol Thread type Rc1/8 Nil NPT1/8 N G1/8 F Valve type Symbol Applicable tubing size Fitting type Symbol Applicable tubing size 1/4" x 5/32" 3/8" x 1/4" Orifice diameter Cv factor Valve type Withstand pressure Operating pressure (1 R 2) [MPa] Back pressure Valve leakage Pilot air pressure 0 (with water pressure) Pilot port size Fluid temperature Ambient temperature Operating frequency Weight Description Actuator section Body

 Open the catalog to page 3
JLV20/30-4

Pilot port Sensor (Breathing) port (E (When the valve is turned ON)) Precautions Be sure to read this before handling the products. Refer to the back cover for safety instructions. For high purity air operated chemical liquid valve precautions, refer to pages 5 and 6.

 Open the catalog to page 4
JLV20/30-5

Applicable Fluids Material and Fluid Compatibility Check List for High Purity Air Operated Chemical Liquid Valves Chemical Ammonium hydroxide Isobutyl alcohol Isopropyl alcohol Hydrochloric acid Hydrogen peroxide Concentration 5% or less, 50°C or less Ethyl acetate Butyl acetate Nitric acid (except fuming nitric acid) Concentration 10% or less Deionized water (pure water) Sodium hydroxide (caustic soda) Concentration 50% or less Super pure water Hydrofluoric acid Sulfuric acid (except fuming sulfuric acid) Table symbols Phosphoric acid Concentration 80% or less : Can be used v : Can be used in...

 Open the catalog to page 5
JLV20/30-6

JLV20/30 Series High Purity Air Operated Chemical Liquid Valve Precautions 1 Be sure to read this before handling the products. Design / Selection 1. onfirm the specifications. C Give careful consideration to the operating conditions, such as the application, fluid, and environment, and use within the specified operating ranges indicated in the catalog. 2. annot be used as an emergency shutoff valve, etc. C The valves presented in this catalog are not designed to be used as emergency shutoff valves in safety applications. If the valves are used in this type of system, other reliable safety assurance...

 Open the catalog to page 6
JLV20/30-7

JLV20/30 Series High Purity Air Operated Chemical Liquid Valve Precautions 2 Be sure to read this before handling the products. Operating Air Supply 1. se clean air. U Do not use compressed air that contains chemicals, synthetic oils that include organic solvents, salt, corrosive gases, etc., as it can cause damage or malfunction. Operating Environment Warning 1. o not use in a location having an explosive atmosD phere. 2. o not use in a place subject to heavy vibration and/ D or shock. 3. o not use in locations where radiated heat will be D received from nearby heat sources. D 4. o not use in...

 Open the catalog to page 7
JLV20/30-8

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious...

 Open the catalog to page 8

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. Series NCQ2/CQ2

    252  Pages

  9. KQG2

    18  Pages

  10. IDF*E

    48  Pages

  11. SYJ300

    60  Pages

  12. 3000 Series

    272  Pages

  13. MTS8

    23  Pages

  14. CXS-A

    60  Pages

  15. CXSL

    60  Pages

  16. MXQR

    36  Pages

  17. NC(D)Q2-Z

    252  Pages

  18. LEY series

    88  Pages

  19. MXH series

    18  Pages

  20. KQ2

    214  Pages

  21. MXQ series

    198  Pages

  22. Fieldbus System

    92  Pages

  23. CQ2 series

    25  Pages

  24. ISG

    10  Pages

  25. ISE3

    8  Pages

  26. ISE2

    7  Pages

  27. ISE1

    5  Pages

  28. ISA

    59  Pages

  29. IS3000

    2  Pages

  30. IS10/10M/10E

    4  Pages

  31. PSE series

    44  Pages

  32. ISE70/75/75H

    10  Pages

  33. ISE80

    17  Pages

  34. ISE40A

    29  Pages

  35. HED series

    16  Pages

  36. HEC series

    32  Pages

  37. HEB series

    9  Pages

  38. HRG series

    85  Pages

  39. HRZ series

    52  Pages

  40. HRW series

    28  Pages

  41. LQ series

    35  Pages

  42. PA series

    37  Pages

  43. LER series

    62  Pages

  44. LEJ series

    58  Pages

  45. LAT3 series

    24  Pages

  46. LEH series

    103  Pages

  47. CQS series

    59  Pages

  48. CH series

    175  Pages

  49. ARX series

    12  Pages

  50. HRS series

    47  Pages

  51. LES

    59  Pages

  52. MHS

    74  Pages

  53. MHY

    27  Pages

  54. MHC

    27  Pages

  55. MHR

    30  Pages

  56. MHZ series

    78  Pages

  57. MSQ

    37  Pages

  58. MGP

    127  Pages

  59. MXS

    38  Pages

  60. NRB

    10  Pages

  61. MXW

    22  Pages

  62. MHT

    11  Pages

  63. MY3

    54  Pages

  64. CQM

    15  Pages

  65. NCA1

    63  Pages

  66. CM2

    152  Pages

  67. NCM

    91  Pages

  68. NCG

    96  Pages

  69. NCRA1

    5  Pages

  70. CS2

    32  Pages

  71. T/TIA

    1  Page

  72. KR

    7  Pages

  73. KF

    16  Pages

  74. KQ

    80  Pages

  75. AFF

    80  Pages

  76. AMG

    80  Pages

  77. IDF

    16  Pages

  78. HAA

    3  Pages

  79. ZFA

    14  Pages

  80. ZA

    13  Pages

  81. MHF

    32  Pages

  82. CRB

    44  Pages

  83. D

    117  Pages

  84. RB

    23  Pages

  85. CEP

    44  Pages

  86. rsq

    30  Pages

  87. CLK

    51  Pages

  88. MK

    20  Pages

  89. CLJ

    65  Pages

  90. MGJ

    7  Pages

  91. ZSE30A

    17  Pages

  92. IDFB*E

    89  Pages

  93. ISE10

    16  Pages

  94. ITV1000/2000

    50  Pages

  95. AW

    27  Pages

  96. NVFM200

    12  Pages

  97. NVM100

    32  Pages

  98. LLA*A

    36  Pages

  99. VX3*

    41  Pages

  100. SY3000

    158  Pages

  101. CH(D)2

    175  Pages

  102. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.