Catalog excerpts
2-Color Display Digital Pressure Switch > Stainless diaphragm Oil-free (Single-layer diaphragm structure) sensor parts: stainless steel 630 Fitting parts: stainless steel 304 The sensor and fitting parts can be made to order with stainless steel 316L. Irregular value at a glance FI?>J|] ■i>I|] ■iMij ■i>I|j with ©©buttons. Choice of 2 piping directions i:Ull.imfc imi.J.l.lUU.fc J Rated pressure range RoHS compliant
Open the catalog to page 1b Sensor and fitting parts are electron-beam welded. b Choice of VCR® or Swagelok® fitting is available. VCR® compliant Swagelok® compliant Confirmation of the atmospheric pressure of a load lock chamber Applicable Fluid Examples ∗ VCR® and Swagelok® are registered trademarks of Swagelok Company. fluid (JIS-K2 213) b Silicon oil (JIS-K2 213) b Lubricant (JIS-K6301) b Fluorocarbon dioxide drainage b Nitrogen b Air-containing Applications Confirmation of adsorption of work pieces containing moisture Confirmation of supply pressure of cleaning lines Confirmation of working pressure of...
Open the catalog to page 2Can select from 4 indicator patterns of color combinations. Rc1/8 (female threaded) is now available. b R1/4 (VCR® fitting compliant) (Swagelok® fitting compliant) Output display Analog current output is newly added. It lights when OUT1 or OUT2 outputs. Convex rubber button when it is wired for a long distance. is resistant against noise. Convex button is adopted and provides IP65 rating. Improved maneuverability and operability. open collector 1 output open collector 2 outputs Lead wire length open collector 1 output open collector 2 outputs open collector 2 outputs + Analog voltage...
Open the catalog to page 32-Color Display Digital Pressure Switch For General Fluids Series ZSE80/ISE80 How to Order Rated pressure range 80 –0.1 to 1 MPa 80H –0.1 to 2 MPa Made to Order Refer to Table 1 below. For vacuum/ compound pressure Rated pressure range 80 80F Note) Calibration Operating Note) Calibration Symbol Operating manual certificate Symbol manual certificate Nil b (Booklet) — b (Booklet) b K — — — b T Y b (CD-ROM) — b (CD-ROM) b R W Rear ported Note) All texts in both English and Japanese Option 1 Note) Fixed unit ISE80H: MPa Others : MPa, kPa With unit display switching function Fixed SI unit Note)...
Open the catalog to page 42-Color Display Digital Pressure Switch For General Fluids (Vacuum pressure) (Compound pressure) (Positive pressure) (Positive pressure) Rated pressure range Withstand pressure Pressure sensor: Stainless steel 630, Fitting: Stainless steel 304 Wetted parts material Fluids do not corrode stainless steel 630 and 304 R1/4, NPT1/4, G1/4∗, URJ1/4, TSJ1/4, Rc1/8 Piping direction: Rear/Bottom Applicable fluid Port size 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Current consumption NPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs...
Open the catalog to page 5Series ZSE80/ISE80 Analog Output Current output Analog output [mA] Voltage output Rated pressure range Note) Analog output is 0.8 [V] or 3.2 [mA] at the pressure A. Range For vacuum pressure Descriptions LCD Output (OUT1) display (Orange) Lights up when OUT1 is turned ON. Output (OUT2) display (Orange) Displays the current pressure, set mode, selected display unit, and error code. Always use red or green display; or switch between green and red according to the output. Four different display settings are available. Lights up when OUT2 is turned ON. SET button button Use this button to...
Open the catalog to page 62-Color Display Digital Pressure Switch For General Fluids Internal Circuits and Wiring Examples -N Main circuit Main circuit Main circuit Max. 28V, 80 mA Residual voltage 1 V or less Max. 80 mA Residual voltage 1 V or less Max. 28V, 80 mA Residual voltage 1 V or less NPN (2 outputs) + Analog voltage output NPN (2 outputs) + Auto-shift input Gray Analog output Gray Auto-shift input Black OUT1 Load – White OUT2 Main circuit Main circuit Main circuit Black OUT1 Load – White OUT2 Max. 80 mA Residual voltage 1 V or less Max. 28V, 80 mA Residual voltage 1 V or less Max. 28V, 80 mA Residual...
Open the catalog to page 7Atmospheric vent port ø2.6 Piping port Rc1/8 Piping port G1/4
Open the catalog to page 82-Color Display Digital Pressure Switch For General Fluids Atmospheric vent port ø2.6
Open the catalog to page 9Series ZSE80/ISE80 Dimensions With bracket (Rear ported) A With bracket (Rear ported) With bracket (Bottom ported) 4 x ø4.5
Open the catalog to page 102-Color Display Digital Pressure Switch For General Fluids Dimensions Panel mount (Rear ported) Panel-cut dimensions
Open the catalog to page 11Series ZSE80/ISE80 Dimensions Panel mount (Bottom ported) Panel-cut dimensions
Open the catalog to page 122-Color Display Digital Pressure Switch For General Fluids F in brackets stand for the function codes. Refer to the operating manual for how to operate and function codes in detail. Function Details A Auto-shift function (F4) When there are large fluctuations in the supply pressure, the switch may fail to operate correctly. The auto-shift function compensates such supply pressure fluctuations. It measures the pressure at the time of auto-shift signal input and uses it as the reference pressure to correct the set-value on the switch. Auto-preset function, when selected in the initial...
Open the catalog to page 13Series ZSE80/ISE80 Function Details I Unit display switching function (F0) G Error indication function Display units can be switched with this function. Error name Error code Overcurrent error Residual pressure error Applied pressure error Auto-shift error Supply pressure exceeds the maximum set pressure. The value measured at the time of auto-shift input is outside the set pressure range. ∗ After displaying the error code for one second, the switch returns to the measuring mode. It is still applied with pressure that is ±10% over the atmospheric pressure and the upper limit of the rated...
Open the catalog to page 14Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. 1 Wetted parts: Stainless steel 316L 2 Lead wire length 3 m This pressure switch has better corrosion resistance that uses stainless steel 316L for the wetted parts (pressure sensor and fitting). ∗ Refer to How to Order on page 732 for standard specifications. It has a lead wire extended to 3 meters. ∗ Refer to How to Order on page 732 for standard specifications. Option∗ Note 1) Not applicable to the rated pressure –0.1 to 2 MPa specifications (ISE80H). Note 2) A restrictor (equivalent to -X510) is...
Open the catalog to page 15All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages