ISE70/75/75H
10Pages

{{requestButtons}}

Catalog excerpts

ISE70/75/75H - 1

2-Color Display Digital Pressure Switch Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure For General Fluids For Air Metal Body Type (Die-cast aluminum) • Selectable from four patterns ON Easily identifiable abnormal readings • Lead wire with M12 connector (5 m) • Straight and right-angled connectors Functions With Bracket • User-selectable mounting orientation • Anti-chattering • Display calibration • Zero-out • Key lock • Unit display switching (Fixed SI unit in Japan) • Withstand pressure: Rated pressure x 3 • Model with initial display settings of PSI is also available as standard. • Port size PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH

Open the catalog to page 1
ISE70/75/75H - 2

2-Color Display Digital Pressure Switch For Air With bracket 2 settings NPN open collector 2 outputs ((Pin no.: 2, 4) Fixed setting: NPN open collector 1 output (Pin no.: 4) + PNP open collector 1 output (Pin no.: 2) PNP open collector 1 output (Pin no.: 4) 2 settings PNP open collector 2 outputs (Pin no.: 2, 4) Note) Mounting screws are not included. With unit display switching function Fixed SI unit Note) Pressure unit: psi (Initial value) With unit display switching function Lead wire with M12 connector (5 m), straight Lead wire with M12 connector (5 m), right-angled Note) Fixed unit:...

Open the catalog to page 2
ISE70/75/75H - 3

2-Color Display Digital Pressure Switch For Air Rated pressure range Set pressure range Withstand pressure Applicable fluid Power supply voltage 12 to 24 VDC±10%, Ripple (p-p) 10% or less (with power supply polarity protection) Current consumption Switch output Output -27: 2 settings; NPN open collector 2 outputs (Pin no.: 2, 4) Output -43: Fixed setting; NPN open collector 1 output (Pin no.: 4) + PNP open collector 1 output (Pin no.: 2) Note 1) Output -65: PNP open collector 1 output (Pin no.: 4) Output -67: 2 settings; PNP open collector 2 outputs (Pin no.: 2, 4) 80 mA Max. load current...

Open the catalog to page 3
ISE70/75/75H - 4

2-Color Display Digital Pressure Switch For General Fluids None With bracket 2 settings NPN open collector 2 outputs (Pin no.: 2, 4) Fixed setting: NPN open collector 1 output (Pin no.: 4) + PNP open collector 1 output (Pin no.: 2) PNP open collector 1 output (Pin no.: 4) 2 settings PNP open collector 2 outputs (Pin no.: 2, 4) None Lead wire with M12 connector (5 m), straight With unit display switching function Display unit Lead wire with M12 connector (5 m), right-angled Pressure unit: psi (Initial value) With unit display switching function Note) Fixed unit: MPa Optional Part No. When...

Open the catalog to page 4
ISE70/75/75H - 5

2-Color Display Digital Pressure Switch For General Fluids Withstand pressure Model Rated pressure range Set pressure resolution Applicable fluid 0.1 MPa Fluid or gas that will not corrode stainless steel 304, 430 and 630 Power supply voltage 12 to 24 VDC±10%, Ripple (p-p) 10% or less (with power supply polarity protection) Current consumption Switch output Output -27: 2 settings; NPN open collector 2 outputs (Pin no.: 2, 4) Output -43: Fixed setting; NPN open collector 1 output (Pin no.: 4) + PNP open collector 1 output (Pin no.: 2) Note 1) Output -65: PNP open collector 1 output (Pin no.:...

Open the catalog to page 5
ISE70/75/75H - 6

Indication light (Green) MPa Displays the switch operation status. Lights up when OUT1 is turned ON. Use this button to switch the mode and set the set value. Displays the current pressure condition, set mode and error code. The display mode can be selected from four options: fixed green single-color reading, fixed red single-color reading, green reading interlocked with output for switching to red reading, or red reading interlocked with output for switching to green reading. UP button Use this button to change the mode or increase the ON/OFF set value. It also allows you to switch to the...

Open the catalog to page 6
ISE70/75/75H - 7

2-Color Display Digital Pressure Switch For General Fluids Functions Error function This function eliminates slight differences in the output values and allows uniformity in the numbers displayed. Displayed values of the pressure sensor can be calibrated to within ±5% of their readings. Take the following corrective solutions when error occurs. Displayed pressure value Display calibration function Error description Overcurrent error : Factory setting display value set prior to shipment : Display calibration range Note) When the display calibration function is used, the set pressure value...

Open the catalog to page 7
ISE70/75/75H - 8

PRESSURE SWITCH Note) The connector faces down (toward the piping). Do not attempt to rotate the connector, as it is not rotatable. Output -43 (Color: Gray) 1 Brown Output -65 (Color: Black) 2 White PRESSURE SWITCH Output -27 and -67 (Color: Gray) (31) (38.7)

Open the catalog to page 8
ISE70/75/75H - 9

Specific Product Precautions 1 Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. Pressure Source 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling. 1. Use of poisonous and deleterious substances, corrosive or combustible fluids Although the body of the sensor may not be damaged, the internal parts of the sensor could be damaged and lead to a malfunction. Do not use fluids such as poisonous and deleterious substances or corrosive gases. Also, note that the switch is not...

Open the catalog to page 9
ISE70/75/75H - 10

Specific Product Precautions 2 Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. Set Pressure Range and Rated Pressure Range Caution 1. Set the pressure to within the rated pressure range. The set pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the switch. Although it is possible to set a value outside the rated pressure range, the specifications will not be...

Open the catalog to page 10

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE80

    17 Pages

  30. ISE40A

    29 Pages

  31. HED series

    16 Pages

  32. HEC series

    32 Pages

  33. HEB series

    9 Pages

  34. HRG series

    85 Pages

  35. HRZ series

    52 Pages

  36. HRW series

    28 Pages

  37. LQ series

    35 Pages

  38. PA series

    37 Pages

  39. LER series

    62 Pages

  40. LEJ series

    58 Pages

  41. LAT3 series

    24 Pages

  42. LEH series

    103 Pages

  43. CQS series

    59 Pages

  44. CH series

    175 Pages

  45. ARX series

    12 Pages

  46. HRS series

    47 Pages

  47. LES

    59 Pages

  48. MHS

    74 Pages

  49. MHY

    27 Pages

  50. MHC

    27 Pages

  51. MHR

    30 Pages

  52. MHZ series

    78 Pages

  53. MSQ

    37 Pages

  54. MGP

    127 Pages

  55. MXS

    38 Pages

  56. NRB

    10 Pages

  57. MXW

    22 Pages

  58. MHT

    11 Pages

  59. MY3

    54 Pages

  60. CQM

    15 Pages

  61. NCA1

    63 Pages

  62. CM2

    152 Pages

  63. NCM

    91 Pages

  64. NCG

    96 Pages

  65. NCRA1

    5 Pages

  66. CS2

    32 Pages

  67. T/TIA

    1 Pages

  68. KR

    7 Pages

  69. KF

    16 Pages

  70. KQ

    80 Pages

  71. AFF

    80 Pages

  72. AMG

    80 Pages

  73. IDF

    16 Pages

  74. HAA

    3 Pages

  75. ZFA

    14 Pages

  76. ZA

    13 Pages

  77. MHF

    32 Pages

  78. CRB

    44 Pages

  79. D

    117 Pages

  80. RB

    23 Pages

  81. CEP

    44 Pages

  82. rsq

    30 Pages

  83. CLK

    51 Pages

  84. MK

    20 Pages

  85. CLJ

    65 Pages

  86. MGJ

    7 Pages

  87. ZSE30A

    17 Pages

  88. IDFB*E

    89 Pages

  89. ISE10

    16 Pages

  90. ITV1000/2000

    50 Pages

  91. AW

    27 Pages

  92. NVFM200

    12 Pages

  93. NVM100

    32 Pages

  94. LLA*A

    36 Pages

  95. VX3*

    41 Pages

  96. SY3000

    158 Pages

  97. CH(D)2

    175 Pages

  98. LEHZ

    82 Pages

  99. M(D)SUB

    31 Pages

  100. CXSJ

    58 Pages

  101. CY3B

    39 Pages

  102. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages