Compact Pressure Switch Series ZSE2 (For Vacuum) / ISE2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. ZSP PS ISA PSE IS ISG ZSM Easy and simple wiring Connector type
Open the catalog to page 1Compact Pressure Switch Series ZSE2/ISE2 How to Order Piping specifications Operating pressure range/ Setting pressure range Nil L Positive pressure Note 1) M5 x 0.8 (female) threaded. Single mounting R 1/8 Note 1) Single mounting NPTF 1/8 Note 1) Wiring specifications Single mounting R 1/8 Note 2) Single mounting NPTF 1/8 Note 2) Grommet type (Lead wire: 3 m) W/suction filter (Mounting on ZX unit) M5 x 0.8 Connector type (Lead wire: 0.6 m) W/suction filter (Mounting on ZX unit) M6 x 1 (Option) Connector type (Lead wire: 3 m) Base mounting (Mounting on ZR unit) Without connector Grommet...
Open the catalog to page 2Compact Pressure Switch Specifications Model Rated pressure range/Set pressure range 0 to –101 kPa 0 to 100 kPa 0 to 1 MPa Proof pressure 500 kPa 1.5 MPa Air/Non-corrosive, non-flammable gas Fluid Power supply voltage 12 to 24 VDC ±10%, Ripple (P-P) 10% or less (With power supply polarity protection) Current consumption 17 mA or less at 24 VDC Response time 5 ms or less Repeatability ±1% F.S. or less Enclosure IP40 Operating temperature range Operating: 0 to 60°C, Stored: –10 to 60°C (With no condensation and no freezing) Operating humidity range Operating/Stored: 35 to 85%RH (With no...
Open the catalog to page 3Calibration Procedure Internal Circuit and Wiring Example • Set the ON-pressure by the pressure setting 1. Attaching and detaching connectors • When assembling the connector to the switch • Pressure setting trimmer housing, push the connector straight onto the pins until the lever locks into the housing slot. When removing the connector from the switch housing, push the lever down to unlock it from the slot and then withdraw the connector straight off of the pin. Lead wire 0.2 to 0.33 mm2 Max. coating O.D. ø1.7 mm Main circuit trimmer. Turning clockwise can set the high pressure/high vacuum...
Open the catalog to page 4Compact Pressure Switch Dimensions/With Suction Filter: ZSE2-0X Grommet type: ZSE2-0X-15 Pressure setting trimmer Vacuum pad connection port Vacuum supply port Pneumatic circuit Vacuum supply port M5 x 0.8 Vacuum pad connection port M5 x 0.8 Vacuum supply port Vacuum pad connection port Pressure setting trimmer Pneumatic circuit 10 Vacuum supply port M5 x 0.8 5.5 Vacuum pad connection port M5 x 0.8
Open the catalog to page 5Connector type: ZSE2- 01 -15C T1 Pressure setting trimmer Pressure setting trimmer SET H L Piping port M5 x 0.8 depth 5 Piping port M5 x 0.8 depth 5 Dimensions/Base Mount Type: ZSE2-0R Grommet type: ZSE2-0R-15 Pressure setting trimmer Connector type: ZSE2-0R-15C Indicator light (Red) Pressure setting trimmer Vacuum supply port ø3.3 Vacuum supply port ø3.3
Open the catalog to page 6Compact Pressure Switch Grommet type: ISE2- 01-15 T1 Pressure setting trimmer Pressure setting trimmer SET H L Piping port M5 x 0.8 depth 5 Piping port M5 x 0.8 depth 5
Open the catalog to page 7All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages