video corpo
cad

ISE/ZSE30A series
1 /18Pages

ISE/ZSE30A series

ISE/ZSE30A series
1 /18Pages

Catalog excerpts

ISE/ZSE30A series-1

2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 10 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. b Reduced setting efforts chance of set-value input error Push Adjust to set-value with buttons. Finish setting Added vacuum range. –101 kPa 1 MPa b Rated pressure range: 0.0 to –101.0 kPa Expanded pressure range for positive-pressure type to the vacuum range. b Rated pressure range: –0.100 to 1.000 MPa 2 added outputs b NPN or PNP open collector 2 outputs b NPN or PNP open collector 1 output + Analog output (1 to 5 V or 4 to 20 mA) RoHS compliant

 Open the catalog to page 1
ISE/ZSE30A series-2

Replaceable one-touch fittings Bracket configuration allows mounting in four orientations. The clip type allows easy removal of fittings. Fitting’s type and size can be changed. One-touch fitting Lead wire Added the connector cover. Connector cover Mounting example Mounting example Lead wire with connector (2 m) Panel mount Mountable side by side without clearance 4-digit display 4-digit display allows easy reading of displayed values. Example: 0.5 MPa One opening! • Reduction of panel-cut job • Space-saving Series 30A (New) Possible to check set-value during key locking Additional functions...

 Open the catalog to page 2
ISE/ZSE30A series-3

2-Color Display High-Precision Digital Pressure Switch Series ZSE30A(F)/ISE30A How to Order Output Rated pressure range ISE30A –0.1 to 1 MPa NPN open collector 1 output PNP open collector 1 output NPN open collector 2 outputs PNP open collector 2 outputs NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output PNP open collector 1 output + Analog voltage output PNP open collector 1 output + Analog current output For vacuum/ compound pressure Rated pressure range ZSE30A ZSE30AF Operating manual Calibration Booklet CD-ROM certificate — — ć — — — —...

 Open the catalog to page 3
ISE/ZSE30A series-4

Series ZSE30A(F)/ISE30A Specifications Model Rated pressure range Set pressure range Withstand pressure Minimum unit setting Applicable fluid Power supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeatability Hystere- Hysteresis mode sis Window comparator mode Note 2) Voltage output Analog output Current output ISE30A (Positive pressure) –100.0 to 100.0 kPa –0.100 to 1.000 MPa –105.0 to 105.0 kPa –0.105 to 1.050 MPa 500 kPa 1.5 MPa 0.1 kPa 0.001 MPa Air, Non-corrosive gas, Non-flammable gas...

 Open the catalog to page 4
ISE/ZSE30A series-5

2-Color Display High-Precision Digital Pressure Switch Analog Output Current output Analog output [mA] Rated pressure range Range For vacuum pressure Unit display Displays present unit (only for units of kPa and MPa). Output (OUT1) display (Green) Lights up when switch output (OUT1) is turned ON. Displays the current pressure, set mode, and error code. Always use red or green display; or switch between green and red according to the output. Four different display settings are available. Output (OUT2) display (Red) Lights up when switch output (OUT2) is turned ON. button (UP) Use this button to...

 Open the catalog to page 5
ISE/ZSE30A series-6

Series ZSE30A(F)/ISE30A Internal Circuits and Wiring Examples Main circuit Main circuit Max. 28 V, 80 mA Residual voltage 1 V or less Max. 80 mA Residual voltage 1 V or less Max. 28 V, 80 mA Residual voltage 1 V or less Main circuit Main circuit Max. 80 mA Residual voltage 1 V or less ∗ The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used. (Refer to “Copy function” on page 10.)

 Open the catalog to page 6
ISE/ZSE30A series-7

2-Color Display High-Precision Digital Pressure Switch NPN (1 output) + Analog voltage output PNP (1 output) + Analog voltage output Main circuit Main circuit White OUT2 Load FUNC Max. 28 V, 80 mA Residual voltage 1 V or less Max. 80 mA Residual voltage 1 V or less Analog voltage output Output impedance: Approx. 1 kΩ Analog voltage output Output impedance: Approx. 1 kΩ NPN (1 output) + Analog current output PNP (1 output) + Analog current output Brown DC (+) Main circuit Main circuit White OUT2 Load FUNC Max. 28 V, 80 mA Residual voltage 1 V or less Max. 80 mA Residual voltage 1 V or less Analog...

 Open the catalog to page 7
ISE/ZSE30A series-8

Lead wire with connector C6H One-touch fitting ø6 mm straight 17.95 One-touch fitting ø4 mm ø5/32 inch elbow One-touch fitting ø6 mm elbow One-touch fitting ø1/4 inch elbow One-touch fitting ø1/4 inch straight One-touch fitting ø4 mm ø5/32 inch straight

 Open the catalog to page 8
ISE/ZSE30A series-9

2-Color Display High-Precision Digital Pressure Switch With bracket Bracket A (Option unit part no.: ZS-38-A1) ∗ Bracket configuration allows mounting in four orientations. Bracket B (Option unit part no.: ZS-38-A2) ∗ Bracket configuration allows mounting in four orientations.

 Open the catalog to page 9
ISE/ZSE30A series-10

Series ZSE30A(F)/ISE30A Dimensions Panel mount B Panel mount adapter (Option unit part no.: ZS-27-C) D Panel mount adapter + Front protection cover (Option unit part no.: ZS-27-D) 42.4

 Open the catalog to page 10
ISE/ZSE30A series-11

2-Color Display High-Precision Digital Pressure Switch Panel-cut dimensions 1 pc. mounting Multiple (2 pcs. or more) horizontal mounting Multiple (2 pcs. or more) vertical mounting 0

 Open the catalog to page 11
ISE/ZSE30A series-12

Series ZSE30A(F)/ISE30A Function Details A Copy function (F97) The settings of the master sensor can be copied to the slave sensors. It is to reduce the time taken for setting and prevent the input of wrong values. Settings can be copied to up to 10 slave sensors at once. (Max. transmission distance: 4 m) Unit 1 1) The sensors are connected by a dedicated lead wire (ZS-38-5L (for master and one slave) or ZS-38-U (for master and up to 10 slaves)). Copying is performed through a dedicated communication line. Slave (Max. 10 units) Slave-side sensor Unit 1 Gray (Line for copying) Blue Gray (Line...

 Open the catalog to page 12
ISE/ZSE30A series-13

2-Color Display High-Precision Digital Pressure Switch F in brackets stand for the function codes. Refer to the operating manual for how to operate and function codes in detail. G Error indication function Error name Error code Solution Shut off the power supply. After eliminating the output factor that caused the excess current, turn the power supply back on. Load current of switch output (OUT1) exceeds 80 mA. Overcurrent error Load current of switch output (OUT2) exceeds 80 mA. A pressure of ±7% F.S. of atmospheric pressure is applied in the zero-out function. (±3.5% F.S. or more for ZSE30AF...

 Open the catalog to page 13

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. VX3*

    41  Pages

  101. SY3000

    158  Pages

  102. CH(D)2

    175  Pages

  103. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.