Refrigerated Air Dryers Series IDF/IDU Standard/High Temperature Air Inlet Type Protect Pneumatic Equipment from Moisture! An air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail. Effects of moisture on equipment Malfunctioning of valves and actuators caused by dripping grease Decomposition of auto drain caused by rusting inside pipes Generation of water droplets Increased up to the Air flow capacity Power consumption Coefficient of destruction for ozone is zero. Note) Except IDF370B Improved corrosion resistance with the use of stainless steel, plate type heat exchanger
Open the catalog to page 1Complies with CFC restrictions 1. Standard Products Series IDF Standard temperature air inlet type Rated inlet air temperature: IDF1E 35, 40°C Rated Air flow capacity (m3/min (ANR)) Applicable air inlet compressor (kW) 50 Hz 60 Hz condition 0.1 High temperature air inlet type Rated inlet air temperature: 55°C Port size Rated Air flow capacity (m3/min (ANR)) Applicable air inlet compressor (kW) 50 Hz 60 Hz condition Port size ∗ Refer to pages 59 and 73 for dryer models conforming with foreign standards (CE and UL).
Open the catalog to page 22. Options Applicable model Cool compressed air output Model (Suffix: Option symbol) Anti-corrosive treatment With heavy duty auto drain (applicable to medium air pressure) For medium air pressure (up to 1.6 MPa) (Auto drain bowl: Metal bowl with level gauge) With motor type auto drain With circuit breaker With terminal block for power supply, run, alarm signal and remote operation Timer type solenoid valve with auto drain (applicable to medium air pressure) Water-cooled condenser Note 1) Power supply terminal block connection Note 1) The IDF370B is equipped as standard. 3. Optional Accessories...
Open the catalog to page 3Series IDF/IDU Model Selection The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting the air dryer. Please select using the following procedures. Reading correction factors Obtain the correction factor A to D suitable for your operating condition from the graph at right. Select IDF or IDU from inlet air temperature used. • Inlet air temperature 5 to 50°C ····· IDF • Inlet air temperature 50 to 80°C ····· IDU Data symbol Correction Note) factor Data symbol Correction Note) factor Ambient temperature Ambient temperature Outlet air pressure dew...
Open the catalog to page 4Model Selection Correction Factors Data A: Inlet Air Temperature Series IDF Correction factor Correction factor Correction factor Correction factor Correction factor Data B: Ambient Temperature Series IDU Correction factor Correction factor Correction factor Data D: Inlet Air Pressure Outlet air pressure Correction factor dew point (°C) IDU55E, 75E Outlet air pressure Correction dew point (°C) factor IDF1E to 75E Inlet air Correction pressure factor (MPa) IDF120D to 370B Inlet air Correction pressure factor (MPa) Inlet air Correction pressure factor (MPa) Inlet air Correction pressure factor...
Open the catalog to page 5Refrigerant R134a (HFC) Standard Temperature Air Inlet (Inlet air temperature: 35°C, Outlet air pressure dew point: 10°C) How to Order Size Size Air compressor size Note) Note) Please note that the above values are for reference only. Therefore, check the actual compressor capacity. Voltage Symbol Applicable size Cool AntiNone compressed corrosive air output treatment For medium air pressure Note 4) Auto drain bowl: Metal bowl with level gauge With heavy duty auto drain (applicable to medium air pressure) Note 4) With motor type auto drain With circuit breaker Note 1) Enter alphabetically when...
Open the catalog to page 6Standard Specifications Standard temperature air inlet Rated conditions Note 3) Operating ranges Electric specifications Refrigerated air dryer Auto drain Inlet air temperature (°C) Inlet air pressure 2 to 40 (Relative humidity of 85% or less) Ambient temp. (humidity) (°C) Air flow capacity (m3/min) Standard Note 1) condition (ANR) Note 2) Compressor intake condition Power supply voltage (frequency) Note 4) Power consumption (W) 50/60 Hz Operating current (A) 50/60 Hz Applicable circuit breaker capacity Note 5) Outlet air pressure dew point (°C) Auto drain (Normally closed) Float type (Normally...
Open the catalog to page 7Illuminated switch Port size Evaporation thermometer Air outlet Port size Ventilation air inlet Ventilation direction Drain tube (O.D. ø10, length approx. 0.8 m) [200 VAC specification] Terminal block Power cable outlet (ø17) [100 VAC specification] Power cable (Length: approx.1.9 m) Illuminated switch Evaporation thermometer Air inlet Port size Ventilation direction Air outlet Port size Ventilation direction Drain tube (O.D. ø10, length approx. 0.8 m) Power cable outlet (ø17) Power cable (Length: approx.1.9 m) Dimensions Model Terminal block
Open the catalog to page 8Refrigerated Air Dryer Series IDFUE Illuminated switch Drain tube Power cable (Length: approx.1.9 m) Power cable outlet (017)
Open the catalog to page 9Standard Temperature Air Inlet (Inlet air temp.: 35°C (22E, 37E), 40°C (55E, 75E), Outlet air pressure dew point: 10°C) Note 1) Enter alphabetically when multiple options are combined. However, the following combinations are not possible. • Combination of K, L and M are not possible because an auto drain can only be attached to a single option. Note 2) Select the option L for the 55E and 75E which need medium air pressure. Note 3) Refer to pages 42 through to 45 for further information on options.
Open the catalog to page 10Standard Specifications Standard temperature air inlet Electric specifications Rated conditions Note 3) Operating ranges Inlet air temperature Inlet air pressure Standard condition (ANR) Note 2) Compressor intake condition 2 to 40 (Relative humidity of 85% or less) Ambient temperature Outlet air pressure dew point (°C) Single-phase/Three-phase: 200 VAC (50 Hz) Note 4) Single-phase/Three-phase: 200/220 VAC (60 Hz) Power supply voltage (frequency) Note 4) Power consumption (W) 50/60 Hz Operating current (A) 50/60 Hz Applicable circuit breaker capacity Note 5) Auto drain Float type (Normally open)...
Open the catalog to page 1167 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages