Standard/High Temperature Air Inlet Type Protect Pneumatic Equipment from Moisture! An air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail. Effects of moisture on equipment actuators caused by dripping grease Decomposition of auto drain caused by rusting inside pipes Generation of water droplets Coefficient of destruction for ozone is zero. Improved corrosion resistance with the use of stainless steel, plate type heat exchanger Standard temperature air inlet [series IDF] High temperature air inlet [series IDU]
Open the catalog to page 1/Complies with CFC restrictions_ I Standard temperature air inlet type Rated inlet air temperature: High temperature air inlet type Rated inlet air temperature: * Refer to pages 59 and 73 for dryer models conforming with foreign standards (CE and UL).
Open the catalog to page 2Note 1) The IDF370B is equipped as standard. Separately installed power transformer Dedicated base for separately installed power transformer Piping adapter
Open the catalog to page 3Series IDF/IDU Model Selection The corrected air flow capacity, which considers the user's operating conditions, is required for selecting the air dryer. Please select using the following procedures. Select IDF or IDU from inlet air temperature used. Reading correction Obtain the correction factor A to D suitable for your operating condition from the graph at right. Note) Values obtained from "Correction Factors" on page 25. Note) Values obtained from "Correction Factors" on page 25. Max. coefficient value is 1.5. Correction factor is 1.5 when the calculation result is 1.5 or greater. Max. coefficient...
Open the catalog to page 4Model Selection Correction Factors Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Outlet Air Pressure Data D: Inlet Air Pressure Data E: Air Flow Capacity Note) In the case of option A (Cool compressed air output), the air flow capacity is different. Refer to page 42 for details.
Open the catalog to page 5Standard Temperature Air Inlet (Inlet air temperature: 35°C, Outlet air pressure dew point: 10°C) Note) Please note that the above values are for reference only. Therefore, check the actual compressor Note 1 ) Enter alphabetically when multiple options are combined. However, the following combinations are not possible. • R and S (Because S function Is also Included In R.) • S and T (Because S function Is also Included In T.) • Combination of K, L and M are not possible because an auto drain can only be attached to a single option. Note 2) Voltage symbol 20 (200 VAC) Is the terminal block connection...
Open the catalog to page 6Refrigerated Air Dryer Series IDFUE Standard Specifications Auto drain Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20°C, relative humidity at 65%] Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32°C] Note 3) Select air dryer according to "Model Selection" (pages 24 and 25) for the models beyond the rated specifications. Note 4) When selecting a power supply voltage, refer to "How to Order" on page 26. Note 5) Install a circuit breaker with a sensitivity of 30 mA. Replacement Parts Body part replacement...
Open the catalog to page 7Series IDFUE Illuminated switch Drain tube Power cable outlet (o17) Power cable (Length: Illuminated switch Drain tube Power cable (Length: Power cable outlet (017)
Open the catalog to page 8Refrigerated Air Dryer Series IDFUE Illuminated switch Drain tube Power cable (Length: approx.1.9 m) Power cable outlet (017)
Open the catalog to page 9Standard Temperature Air Inlet (Inlet air temp.: 35°C (22E, 37E), 40°C (55E, 75E), Outlet air pressure dew point: 10°C) Note) Please note that the above values are for reference only. Therefore, check the actual compressor Note 1 ) Enter alphabetically when multiple options are combined. However, the following combinations are not possible. • Combination of K, L and M are not possible because an auto drain can only be attached to a single option. Note 2) Select the option L for the 55E and 75E which need medium air pressure. Note 3) Refer to pages 42 through to 45 for further Information on options....
Open the catalog to page 10Refrigerated Air Dryer Series IDFUE Standard Specifications Auto drain Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20°C, relative humidity Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32°C] Note 3) Select air dryer according to "Model Selection" (pages 24 and 25) for the models beyond the rated Note 4) When selecting a power supply voltage, refer to "How to Order" on page 30. Note 5) Install a circuit breaker with a sensitivity of 30 inA. Replacement Parts Note 6) The part number for the auto drain components...
Open the catalog to page 11Series IDFUE (Electric wire diameter (Electric wire diameter
Open the catalog to page 12Standard Temperature Air Inlet (Inlet air temp.: 40°C (120D, 150D, 190D, 240D), 35°C (370B), Outlet air pressure dew point: 10°C) Port size* Note 1) Combination of a voltage symbol "9" and an option symbol "W" is not available. (Order Transformer separately.) Note 2) Enter alphabetically when multiple Note 3) Refer to pages 42 through to 46 for further information on options. Note 1 ) When more than one operation is required, indicate in numeric order. Note 2) Refer to pages 42 and 44 for further Note 3) Not applicable to the medium air Note) Transformer integrated into the base
Open the catalog to page 13Standard Specifications Water-Cooled Condenser Note 1) Value when cooling water inlet temperature is 32°C and with rated load Note 2) Calculated at 1 RT = 3,300 kcal/h Motor Type Auto Drain Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20°C, relative humidity at 65%] Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32°C] Note 3) Select air dryer according to "Model Selection" (pages 24 and 25) for the models beyond the rated specifications. Note 4) When selecting a power supply voltage, refer to "How to Order"...
Open the catalog to page 1467 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages