1. Catalogs
  2. SMC Corporation of America
  3. IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania
video corpo
cad

IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania
1 /12Pages

IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania

IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania
1 /12Pages

Catalog excerpts

IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-1

Refrigerated Air Dryer ILaige Size Series New* EC Directive compliant (with CE marking) For use in Europe, Asia and Oceania Three-phase 380 VAC (For Asia and Oceania) PoeS^tu% environments- Tolerant of high \ %Z^Pr^mms Top of its class in the industry for the large air-cooled type (I Ambient temperature 45°C at max. [Conventional large type: 40°C] ||| Inlet air temperature 60°C at max. [Conventional large type: 50°C] Energy Saving design with secondary heater (SMC's original new design!) Exhaust heat reduced by £.0% at max. (8 kw—6 kw) Ambient temperature increase suppressed (Air-cooled type) Employs a heat exchanger made of high corrosion- resistant stainless steel. •Dustproof filter •Only access from front side is required to check electrical equip- ment and dustproof filter. Space saving One side can be installed flat '* Installation space reduced by

 Open the catalog to page 1
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-2

Tolerant of high temperature environment (ambient temperature 45 C), Energy saving design! Air-cooled type can be used at ambient temperature 45 C. Secondary heater helps the heat radiation of the condenser allows use at ambient temperature 45 C. New dryer Conventional dryer It cannot radiate heat if the ambient temperature is excessive. Compressed Secondary heater cools the refrigerant and air outlet reduces the load to the It is warmed by condenser. the secondary heater, preventing condensation of the piping on the outlet side. Secondary heater Compressor for refrigeration Refrigerant Compressed...

 Open the catalog to page 2
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-3

Series IDFA100F/125F/150F Maintenance Dustproof filter Only access from front side is required to check electrical equipment and dustproof filter. Dustproof filter Electrical equipment Space saving Either the left or right can be installed flat against a wall! Note) Installation space reduced by 1.5 m2 at max!! Note) Leave a space of at least 600 mm between the heat exhausting face and the wall. Leave at least 600 mm on the sides indicated with . Installation space of the IDFA100F (Example: Installed flat against the wall on the left) Installation space of the conventional type SMC Air Dryer...

 Open the catalog to page 3
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-4

Model Selection The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting air dryer. Select using the following procedures. However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted, the amount of processed air of 400 VAC can be found.) Read the correction factors. Obtain the correction factors to suitable for your operating condition from the below table. Data symbol Correction...

 Open the catalog to page 4
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-5

For use in Europe, Asia and Oceania (Max. inlet air temperature: 60 C, Max. ambient temperature: 45 C) How to Order IDFA 100 F 38 Size Size Option Voltage Symbol Note) Anti-corrosive treatment for copper tube Moderate pressure specification With a circuit breaker With a timer controlled solenoid valve type auto drain Note) Enter alphabetically when multiple options are combined. Example: When the IDFA100F-38 is provided with options C or R or V, the model number will be the IDFA100F-38-CRV. IDFA 100 F 40 Size Size Option Voltage Symbol Note) Anti-corrosive treatment for copper tube Moderate pressure...

 Open the catalog to page 5
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-6

Series IDFA100F/125F/150F Standard Specifications Rated conditions Operating range Note 3) For use in Asia and Oceania For use in Europe Model Specifications IDFA100F-38 IDFA125F-38 IDFA150F-38 IDFA100F-40 IDFA125F-40 IDFA150F-40 Fluid Compressed air Inlet air temperature °C 5 to 60 Inlet air pressure MPa 0.15 to 1.0/0.15 to 1.6 for option K Ambient temperature (humidity) °C 2 to 45 (Relative humidity 85% or less) Standard condition (ANR) Note 1) Compressor intake Note 2) condition Electric specifications Inlet air pressure MPa Inlet air temperature °C Ambient temperature °C Outlet air pressure...

 Open the catalog to page 6
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-7

Port size Port size

 Open the catalog to page 7
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-8

Refer to “How to Order” page 2 for optional models. Option symbol Anti-corrosive treatment for copper tube This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. (Corrosion cannot be completely prevented.) Special epoxy coating: Copper tube and copper alloy parts The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by the coating. Option symbol Moderate pressure specification The maximum operating pressure is 1.6 MPa. The internal drain...

 Open the catalog to page 8
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-9

Condensed Water Calculation Amount of condensed water C–H 18.2 – 3.0 = 15.2 g/m3 C Ambient temperature (Air compressor intake air temperature) ( C) How to calculate the amount of condensed water Dew Point Conversion Chart 60 50 Atmospheric pressure dew point ( C) How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point 10 C and a pressure 0.7 MPa. 1. Trace the arrow mark starting from the point A at a pressure dew point 10 C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark starting...

 Open the catalog to page 9
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-10

Specific Product Precautions 1 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Air Preparation Equipment Precautions. • Avoid locations where the air dryer will be in direct contact with wind and rain. (Avoid locations where relative humidity is 85% or more.) • Avoid exposure to direct sunlight. • Avoid locations that contain much dust, corrosive gases, or flammable gases. Failure due to corrosion is not covered under warranty. However, when the risk of corrosion is high, select the option C (anti-corrosive treatment...

 Open the catalog to page 10
IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania-11

Specific Product Precautions 2 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Air Preparation Equipment Precautions. Caution Use an air compressor with an air delivery of 50 L/min or larger. Since the auto drain is designed in such a way that the valve remains open unless the air pressure rises to 0.05 MPa or higher, air will blow out from the drain outlet at the time of air compressor start up until the pressure increases. Therefore, if an air compressor has a small air delivery, the pressure may not be sufficient....

 Open the catalog to page 11

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. VX3*

    41  Pages

  101. SY3000

    158  Pages

  102. CH(D)2

    175  Pages

  103. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.