IDFA*F, Refrigerated Air Dryer, Sizes 100~150, Standard Inlet Air Temperature for Use in Europe, Asia, and Oceania
12Pages
Catalog excerpts
Refrigerated Air Dryer ILaige Size Series New* EC Directive compliant (with CE marking) For use in Europe, Asia and Oceania Three-phase 380 VAC (For Asia and Oceania) PoeS^tu% environments- Tolerant of high \ %Z^Pr^mms Top of its class in the industry for the large air-cooled type (I Ambient temperature 45°C at max. [Conventional large type: 40°C] ||| Inlet air temperature 60°C at max. [Conventional large type: 50°C] Energy Saving design with secondary heater (SMC's original new design!) Exhaust heat reduced by £.0% at max. (8 kw—6 kw) Ambient temperature increase suppressed (Air-cooled type) Employs a heat exchanger made of high corrosion- resistant stainless steel. •Dustproof filter •Only access from front side is required to check electrical equip- ment and dustproof filter. Space saving One side can be installed flat '* Installation space reduced by
Open the catalog to page 1Tolerant of high temperature environment (ambient temperature 45 C), Energy saving design! Air-cooled type can be used at ambient temperature 45 C. Secondary heater helps the heat radiation of the condenser allows use at ambient temperature 45 C. New dryer Conventional dryer It cannot radiate heat if the ambient temperature is excessive. Compressed Secondary heater cools the refrigerant and air outlet reduces the load to the It is warmed by condenser. the secondary heater, preventing condensation of the piping on the outlet side. Secondary heater Compressor for refrigeration Refrigerant...
Open the catalog to page 2Series IDFA100F/125F/150F Maintenance Dustproof filter Only access from front side is required to check electrical equipment and dustproof filter. Dustproof filter Electrical equipment Space saving Either the left or right can be installed flat against a wall! Note) Installation space reduced by 1.5 m2 at max!! Note) Leave a space of at least 600 mm between the heat exhausting face and the wall. Leave at least 600 mm on the sides indicated with . Installation space of the IDFA100F (Example: Installed flat against the wall on the left) Installation space of the conventional type SMC Air...
Open the catalog to page 3Model Selection The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting air dryer. Select using the following procedures. However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted, the amount of processed air of 400 VAC can be found.) Read the correction factors. Obtain the correction factors to suitable for your operating condition from the below table. Data symbol...
Open the catalog to page 4For use in Europe, Asia and Oceania (Max. inlet air temperature: 60 C, Max. ambient temperature: 45 C) How to Order IDFA 100 F 38 Size Size Option Voltage Symbol Note) Anti-corrosive treatment for copper tube Moderate pressure specification With a circuit breaker With a timer controlled solenoid valve type auto drain Note) Enter alphabetically when multiple options are combined. Example: When the IDFA100F-38 is provided with options C or R or V, the model number will be the IDFA100F-38-CRV. IDFA 100 F 40 Size Size Option Voltage Symbol Note) Anti-corrosive treatment for copper tube Moderate...
Open the catalog to page 5Series IDFA100F/125F/150F Standard Specifications Rated conditions Operating range Note 3) For use in Asia and Oceania For use in Europe Model Specifications IDFA100F-38 IDFA125F-38 IDFA150F-38 IDFA100F-40 IDFA125F-40 IDFA150F-40 Fluid Compressed air Inlet air temperature °C 5 to 60 Inlet air pressure MPa 0.15 to 1.0/0.15 to 1.6 for option K Ambient temperature (humidity) °C 2 to 45 (Relative humidity 85% or less) Standard condition (ANR) Note 1) Compressor intake Note 2) condition Electric specifications Inlet air pressure MPa Inlet air temperature °C Ambient temperature °C Outlet air...
Open the catalog to page 6Port size Port size
Open the catalog to page 7Refer to “How to Order” page 2 for optional models. Option symbol Anti-corrosive treatment for copper tube This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. (Corrosion cannot be completely prevented.) Special epoxy coating: Copper tube and copper alloy parts The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by the coating. Option symbol Moderate pressure specification The maximum operating pressure is 1.6 MPa. The internal...
Open the catalog to page 8Condensed Water Calculation Amount of condensed water C–H 18.2 – 3.0 = 15.2 g/m3 C Ambient temperature (Air compressor intake air temperature) ( C) How to calculate the amount of condensed water Dew Point Conversion Chart 60 50 Atmospheric pressure dew point ( C) How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point 10 C and a pressure 0.7 MPa. 1. Trace the arrow mark starting from the point A at a pressure dew point 10 C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark...
Open the catalog to page 9Specific Product Precautions 1 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Air Preparation Equipment Precautions. • Avoid locations where the air dryer will be in direct contact with wind and rain. (Avoid locations where relative humidity is 85% or more.) • Avoid exposure to direct sunlight. • Avoid locations that contain much dust, corrosive gases, or flammable gases. Failure due to corrosion is not covered under warranty. However, when the risk of corrosion is high, select the option C (anti-corrosive...
Open the catalog to page 10Specific Product Precautions 2 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Air Preparation Equipment Precautions. Caution Use an air compressor with an air delivery of 50 L/min or larger. Since the auto drain is designed in such a way that the valve remains open unless the air pressure rises to 0.05 MPa or higher, air will blow out from the drain outlet at the time of air compressor start up until the pressure increases. Therefore, if an air compressor has a small air delivery, the pressure may not be...
Open the catalog to page 11All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages