1. Catalogs
  2. SMC Corporation of America
  3. IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature
video corpo
cad

IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature
1 /22Pages

IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature

IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature
1 /22Pages

Catalog excerpts

IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-1

by using se sor!! l scroll compres digita Digital scroll compressor Stainless steel heat exchanger depletion potential ZERO refrigerant Conventional dryer Power consumption Double energy saving function series Second re-heater Second re-heater only (Standard model) Double energy saving function series 0 Load factor (%) Energy saving design Power consumption ∗1.Operating conditions: The IDF125FS operated in the energy saving operation mode Ambient temperature 90°F (32°C) Inlet air temperature 104°F (40°C) Ȝ Inlet air pressure 102 psi (0.7 MPa) Ȝ Air flow rate = Rated flow x 0.4 Ȝ Power supply frequency 60 Hz Ȝ Power supply voltage 200 V Ȝ Set dew point = 86°F (30°C) Ȝ Tolerant of high temperature environment! Ambient temperature : Up to 113°F (45°C) Ȝ Inlet air temperature : Up to 140°F (60°C) Ȝ Optimal operation by switching between the energy saving operation mode and the normal operation mode depending on the season and operating environment ∗ Refer to the page “Features 4” for details.

 Open the catalog to page 1
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-2

Second re-heater Second re-heater Digital scroll compressor Conventional dryer Digital scroll compressor Power consumption Energy saving design Energy saving effects of the double energy Double energy saving function series reduces power consumption Second re-heater only (Standard model) 0 Operating conditions: The IDF125FS operated in the energy saving operation mode Ȝ Ambient temperature 90°F (32°C) Ȝ Inlet air temperature 104°F(40°C) Ȝ Inlet air pressure 102 psi (0.7 MPa) Ȝ Air flow rate = Rated flow x 0.4 Ȝ Power supply frequency 60 Hz Ȝ Power supply voltage 200 V Ȝ Set dew point = 86°F (30°C)...

 Open the catalog to page 2
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-3

saving function series Image Double energy saving function series Second re-heater + Digital scroll compressor Load factor (%) Load factor Operating conditions that increase load factor: Digital scroll compressor High inlet air temperature and ambient temperature A large amount of air to be processed Difference in the energy saving efficiency between different kinds of compressors Image Constant compressor operation (without control) controls the compressor output depending on the load factor. Reduces power consumption of the dryer! Load factor Operating conditions that increase load factor:...

 Open the catalog to page 3
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-4

Refrigerated Air Dryer Effect example 1 year (Spring to Winter) Power consumption Compared with the standard model (constant compressor operation), double energy saving function series per year reduces power consumption by Note) The IDF125FS is used for this example. Double energy saving function series (IDF125FS) Standard model (IDF125F) Note) [Trial calculation conditions] Days of operation per year = 240 days (60 days each in spring, summer, autumn and winter), Operation hours per day = 12 hours, Operating conditions = Refer to the conditions shown below. Power consumption of the standard...

 Open the catalog to page 4
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-5

Convenient functions Clear digital display (This displays the operation factor (dryer output) as an example.) Easy-to-see LED even in a dark place Fault diagnosis with alarm codes Alarm code Example E02 Fan motor failure Alarm name Main cause Abnormal phase Phase sequence reversal or open phase Thermal trip Clogging of the dust filter, overload, or compressor failure Compression pressure failure Clogging of the dust filter or overload Compression pressure warning Continue Clogging of the dust filter or overload Operation mode can be set either in the energy saving operation mode ∗1 or normal...

 Open the catalog to page 5
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-6

Maintenance Ⴇ Reduces maintenance hours by using a stainless steel heat exchanger with higher corrosion resistance. Ⴇ Dustproof filter Ⴇ Only access from front side is required to check electrical equipment and dustproof filter. Electrical equipment Dustproof filter Selection of layout Ⴇ Exhausting direction can be selected from four directions!! Ⴇ Auto drain tube can be connected in two directions, left or right. Avoid exhausting air onto adjacent equipment. Space saving Can be installed flat against a wall∗1! e Installation spac reduced by 2 up to 1.5 m ∗1: One side only (either left or right)...

 Open the catalog to page 6
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-7

Air Dryer Variations Series Standard inlet air temperature type Rated inlet air temperature: 95, 104°F (35, 40°C) [Max. inlet air temperature: 122°F (50°C), 140°F (60°C) (F and FS type only)] Refer to SMC website for details. Air flow capacity (scfm [ANR]) Power supply voltage (Frequency) Port size Double energy saving function series Large size series Note) Note that the above value is for reference only. Check the actual compressor capacity. ∗ Refer to the separate catalog. (IDF1E to 370D) High inlet air temperature type Rated inlet air temperature: 131°F (55°C) [Max. inlet air temperature:...

 Open the catalog to page 7
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-8

Model Selection The corrected air ow capacity, which considers the user’s operating conditions, is required for selecting air dryer. Select using the following procedures. Read the correction factors. Obtain the correction factors A to D suitable for your operating condition from the table on the next page. Data symbol Ambient temperature Air ow rate Power supply frequency Outlet air pressure dew point Inlet air pressure Correction factor Note) Values obtained from “Correction Factors” below. Correction factor = 0.92 x 0.98 x 1 x 0.93 = 0.84 Max. coefcient value is 1.5. Correction factor is 1.5...

 Open the catalog to page 8
IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature-9

Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 140°F (60°C) RoHS (Max. ambient temperature: 113°F (45°C) How to Order Note) Note that the above values are for reference only. Check the actual compressor capacity. Heat exhausting direction Voltage Symbol Options Symbol Note) Description None Anti-corrosive treatment for copper tube Moderate pressure specication With a metal name plate Heat exhaust from the rear Heat exhaust from the right Note) Heat exhaust from the left Note) Heat exhaust from the top Note) Note) The combination of 1, 2 and 3 is not available....

 Open the catalog to page 9

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. VX3*

    41  Pages

  101. SY3000

    158  Pages

  102. CH(D)2

    175  Pages

  103. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.