IDF*FS, Refrigerated Air Dryer, Sizes 100~150 w/Energy Saving Function, Standard Inlet Air Temperature
22Pages
Catalog excerpts
by using se sor!! l scroll compres digita Digital scroll compressor Stainless steel heat exchanger depletion potential ZERO refrigerant Conventional dryer Power consumption Double energy saving function series Second re-heater Second re-heater only (Standard model) Double energy saving function series 0 Load factor (%) Energy saving design Power consumption ∗1.Operating conditions: The IDF125FS operated in the energy saving operation mode Ambient temperature 90°F (32°C) Inlet air temperature 104°F (40°C) Ȝ Inlet air pressure 102 psi (0.7 MPa) Ȝ Air flow rate = Rated flow x 0.4 Ȝ Power supply frequency 60 Hz Ȝ Power supply voltage 200 V Ȝ Set dew point = 86°F (30°C) Ȝ Tolerant of high temperature environment! Ambient temperature : Up to 113°F (45°C) Ȝ Inlet air temperature : Up to 140°F (60°C) Ȝ Optimal operation by switching between the energy saving operation mode and the normal operation mode depending on the season and operating environment ∗ Refer to the page “Features 4” for details.
Open the catalog to page 1Second re-heater Second re-heater Digital scroll compressor Conventional dryer Digital scroll compressor Power consumption Energy saving design Energy saving effects of the double energy Double energy saving function series reduces power consumption Second re-heater only (Standard model) 0 Operating conditions: The IDF125FS operated in the energy saving operation mode Ȝ Ambient temperature 90°F (32°C) Ȝ Inlet air temperature 104°F(40°C) Ȝ Inlet air pressure 102 psi (0.7 MPa) Ȝ Air flow rate = Rated flow x 0.4 Ȝ Power supply frequency 60 Hz Ȝ Power supply voltage 200 V Ȝ Set dew point = 86°F...
Open the catalog to page 2saving function series Image Double energy saving function series Second re-heater + Digital scroll compressor Load factor (%) Load factor Operating conditions that increase load factor: Digital scroll compressor High inlet air temperature and ambient temperature A large amount of air to be processed Difference in the energy saving efficiency between different kinds of compressors Image Constant compressor operation (without control) controls the compressor output depending on the load factor. Reduces power consumption of the dryer! Load factor Operating conditions that increase load...
Open the catalog to page 3Refrigerated Air Dryer Effect example 1 year (Spring to Winter) Power consumption Compared with the standard model (constant compressor operation), double energy saving function series per year reduces power consumption by Note) The IDF125FS is used for this example. Double energy saving function series (IDF125FS) Standard model (IDF125F) Note) [Trial calculation conditions] Days of operation per year = 240 days (60 days each in spring, summer, autumn and winter), Operation hours per day = 12 hours, Operating conditions = Refer to the conditions shown below. Power consumption of the...
Open the catalog to page 4Convenient functions Clear digital display (This displays the operation factor (dryer output) as an example.) Easy-to-see LED even in a dark place Fault diagnosis with alarm codes Alarm code Example E02 Fan motor failure Alarm name Main cause Abnormal phase Phase sequence reversal or open phase Thermal trip Clogging of the dust filter, overload, or compressor failure Compression pressure failure Clogging of the dust filter or overload Compression pressure warning Continue Clogging of the dust filter or overload Operation mode can be set either in the energy saving operation mode ∗1 or...
Open the catalog to page 5Maintenance Ⴇ Reduces maintenance hours by using a stainless steel heat exchanger with higher corrosion resistance. Ⴇ Dustproof filter Ⴇ Only access from front side is required to check electrical equipment and dustproof filter. Electrical equipment Dustproof filter Selection of layout Ⴇ Exhausting direction can be selected from four directions!! Ⴇ Auto drain tube can be connected in two directions, left or right. Avoid exhausting air onto adjacent equipment. Space saving Can be installed flat against a wall∗1! e Installation spac reduced by 2 up to 1.5 m ∗1: One side only (either left or...
Open the catalog to page 6Air Dryer Variations Series Standard inlet air temperature type Rated inlet air temperature: 95, 104°F (35, 40°C) [Max. inlet air temperature: 122°F (50°C), 140°F (60°C) (F and FS type only)] Refer to SMC website for details. Air flow capacity (scfm [ANR]) Power supply voltage (Frequency) Port size Double energy saving function series Large size series Note) Note that the above value is for reference only. Check the actual compressor capacity. ∗ Refer to the separate catalog. (IDF1E to 370D) High inlet air temperature type Rated inlet air temperature: 131°F (55°C) [Max. inlet air...
Open the catalog to page 7Model Selection The corrected air ow capacity, which considers the user’s operating conditions, is required for selecting air dryer. Select using the following procedures. Read the correction factors. Obtain the correction factors A to D suitable for your operating condition from the table on the next page. Data symbol Ambient temperature Air ow rate Power supply frequency Outlet air pressure dew point Inlet air pressure Correction factor Note) Values obtained from “Correction Factors” below. Correction factor = 0.92 x 0.98 x 1 x 0.93 = 0.84 Max. coefcient value is 1.5. Correction factor is...
Open the catalog to page 8Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 140°F (60°C) RoHS (Max. ambient temperature: 113°F (45°C) How to Order Note) Note that the above values are for reference only. Check the actual compressor capacity. Heat exhausting direction Voltage Symbol Options Symbol Note) Description None Anti-corrosive treatment for copper tube Moderate pressure specication With a metal name plate Heat exhaust from the rear Heat exhaust from the right Note) Heat exhaust from the left Note) Heat exhaust from the top Note) Note) The combination of 1, 2 and 3 is not...
Open the catalog to page 9Series IDF100FS/125FS/150FS Standard Specications Model Rated conditions Compressed air 41 to 140°F (5 to 60°C) 22 to 145 psi (0.15 to 1.0)/22 to 232 psi (0.15 to 1.6 (Option K) Ambient temperature (humidity) 36 to 113°F (2 to 45°F) (Relative humidity 85% or less) Outlet air pressure dew point set range Note 2), Note 3) 50 to 86°F (10 to 30°F) 882.8 (25) 709.8 (20.1) 565.0 (16) Air ow Standard condition 50 Hz Note 4) 953.4 (27) capacity (ANR) 836.9 (23.7) 663.8 (18.8) 60 Hz scfm 918.1 (26) 738.0 (20.9) 590.0 (16.7) Compressor intake 50 Hz (m3/min) condition Note 5) 992.2 (28.1) 872.2 (24.7)...
Open the catalog to page 10All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages