IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature

IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature
1 / 15 PagesView full catalog

IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature

Product catalog summary
Overview: This document outlines the specifications and features of the IDF100F, IDF125F, and IDF150F series refrigerated air dryers, available in both air-cooled and water-cooled models. These dryers are designed for high-temperature environments and include energy-saving features.
Specifications:
  • Models: Includes both air-cooled (IDF100F-30, IDF125F-30, IDF150F-30) and water-cooled (IDF100F-30-W, IDF125F-30-W, IDF150F-30-W) versions.
  • Refrigeration Method: Options for air-cooled and water-cooled.
  • Rated Inlet Condition: 40°C, 0.7 MPa.
  • Air Flow Capacity: Varies by model and frequency (50 Hz and 60 Hz).
  • Applicable Air Compressor: 100 kW, 125 kW, 150 kW.
  • Refrigerant: R407C (HFC).
  • Port Size: R2, 65A flange, 80A flange.
Features:
  • High Temperature Tolerance: Operates in ambient temperatures up to 45°C and inlet air temperatures up to 60°C.
  • Energy Saving Design: Features a secondary heater to reduce exhaust heat by 25%.
  • Maintenance: Easy access to dustproof filter and electrical equipment from the front side.
  • Space Saving: Can be installed flat against a wall, saving up to 1.5 m² of space.
  • Layout Flexibility: Adjustable exhaust and piping directions for both air-cooled and water-cooled types.
Performance and Efficiency:
  • Air Flow Capacity Increase: Up to 40% increase compared to previous models.
  • Power Consumption Reduction: Up to 40% reduction compared to previous models.
  • Heat Exchanger: Made of high corrosion-resistant stainless steel.
Model Selection: Provides a detailed procedure for selecting the appropriate model based on corrected air flow capacity and operating conditions.
Options and Customization: Includes anti-corrosive treatment, moderate pressure specifications, and different heat exhausting directions.
Installation Guidelines:
  • Avoid locations with vibration, freezing drains, or temperatures over 45°C.
  • Ensure exhaust air does not affect neighboring equipment.
  • Do not install on transport machines like vehicles or ships.
  • Use the provided polyurethane tube for drainage, ensuring it is not bent or crushed.
Electrical and Piping Instructions:
  • Connect power supply to the terminal block and install a suitable circuit breaker.
  • Maintain voltage fluctuation within 10% of the rated voltage.
  • Ensure correct air piping connections and install bypass piping for maintenance.
  • Check for vibrations from the compressor affecting the air dryer.
Operational Precautions:
  • Protection circuit activates if conditions exceed specified limits.
  • Ensure ventilation ports are unobstructed.
Transportation and Handling:
  • Transport according to laws and regulations due to refrigerant content.
  • Use a forklift or lifting hook for transportation, ensuring the product is not laid down.
Maintenance and Safety:
  • Use an air compressor with a delivery of 50 L/min or larger.
  • Regularly clean the ventilation area and check the auto drain operation.
  • Allow at least three minutes before restarting the air dryer to avoid protection circuit activation.
Facility Water Quality Standards:
  • Use facility water within specified pH and conductivity ranges.
  • Install a filter if foreign matter is likely to enter the fluid.
Safety and Compliance:
  • Only trained personnel should operate machinery and equipment.
  • Ensure safety measures are in place before servicing or removing equipment.
  • Consult SMC for use in non-standard conditions or industries.
Warranty and Compliance:
  • The product has a warranty period of 1 year in service or 1.5 years after delivery.
  • Use of SMC products in the manufacture of weapons is prohibited.
  • Follow relevant security laws for international transactions.
See more

Catalog excerpts

IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-1

Refrigerated Air Dryer Large Size Series New in highstop even Doesn’t nts environme mperature te rooms! ompressor such as c Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type Ambient temperature 45 C at max. [Conventional large type: 40 C] Inlet air temperature 60 C at max. [Conventional large type: 50 C] Energy saving design with secondary heater (SMC’s original new design!) Exhaust heat reduced by 25% at max. (12 kW [Patent Pending] Ambient temperature increase suppressed (Air-cooled type) Facility water reduced (Water-cooled type) Employs a heat exchanger made of high corrosion-resistant stainless steel. Maintenance Dustproof filter With a lamp to indicate when to check the dustproof filter Only access from front side is required to check electrical equipment and dustproof filter. Selection of layout [Air-cooled type] [Water-cooled type] Exhausting direction can be selected from four directions!! Facility water piping port can be selected from two directions!! Space saving One side can be installed flat against a wall! Installation space reduced by 1.5 m2 at max!! (IDF100F) Air-cooled type Air flow capacity (m3/min [ANR]) Refrigeration method Air-cooled Water-cooled Air-cooled Water-cooled Air-cooled Water-cooled Rated inlet condition Standard condition Compressor intake (ANR) condition 50 Hz 60 Hz 50 Hz 60 Hz Water-cooled type Applicable air compressor (kW) Port size

 Open the catalog to page 1
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-2

Tolerant of high temperature environment (ambient temperature 45 C), Energy saving design! Air-cooled type can be used at ambient temperature 45 C. Secondary heater helps the heat radiation of the condenser allows use at ambient temperature 45 C. New dryer Conventional dryer It cannot radiate heat if the ambient temperature is excessive. Compressed Secondary heater cools the refrigerant and air outlet reduces the load to the It is warmed by condenser. the secondary heater, preventing condensation of the piping on the outlet side. Secondary heater Condenser Compressor for refrigeration Condenser...

 Open the catalog to page 2
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-3

Series IDF100F/125F/150F Maintenance Dustproof filter Dustproof filter Only access from front side is required to check electrical equipment and dustproof filter. Electrical equipment Selection of layout [Water-cooled type] [Air-cooled type] Facility water piping port can be selected from two directions!! Exhausting direction can be selected from four directions!! Auto drain tube can be connected in two directions, left or right. Left Facility water outlet Right Facility water outlet Facility water inlet Facility water inlet Temperature control equipment Avoid exhausting air onto adjacent equipment....

 Open the catalog to page 3
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-4

Model Selection The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting air dryer. Select using the following procedures. Read the correction factors. Obtain the correction factors to suitable for your operating condition from the below table. Data symbol Correction Note) factor Ambient temperature Outlet air pressure dew point Power supply frequency Note) Values obtained from the below “Correction Factors” Calculate the corrected air flow capacity. Correction factor = 0.92 x 0.98 x 1 x 0.93 = 0.84 Max. coefficient value is 1.5 Correction factor...

 Open the catalog to page 4
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-5

Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 60 C, Max. ambient temperature: 45 C) How to Order Size Size Air compressor size Note) Note) Note that the above value is for reference only. Check the actual compressor capacity. Heat exhaust from the rear Heat exhaust from the right Note) Heat exhaust from the left Note) Heat exhaust from the top Note) Note) The combination of 1, 2 and 3 is not available. (Heat exhausting face can be specified on one side only.) Option Symbol Note 1) Heat exhausting direction Symbol None Easy outdoor installation specification (Air-cooled...

 Open the catalog to page 5
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-6

Series IDF100F/125F/150F Standard Specifications: Air-cooled Type Model Rated conditions Operating range Note 3) Specifications Fluid Ambient temperature (humidity) C Standard 50 Hz condition Air flow (ANR) Note 1) 60 Hz capacity Compressor 50 Hz m3/min intake Note 2) 60 Hz condition MPa Inlet air pressure Ambient temperature Outlet air pressure dew point Exhaust heat from condenser (50/60 Hz) kW Dryer outlet air temperature Electric specifications Power supply voltage (frequency) Applicable circuit breaker capacity Note 4) A Auto drain Heavy duty auto drain (Normally open) Port size Body panel:...

 Open the catalog to page 6
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-7

Standard Specifications: Water-cooled Type Operating range Note 3) Specifications Fluid Inlet air temperature Inlet air pressure Ambient temperature (humidity) Electric specifications Rated conditions C MPa C Standard 50 Hz Air flow condition Note 1) 60 Hz capacity (ANR) Compressor 50 Hz 3/min m intake condition Note 2) 60 Hz Inlet air pressure MPa Inlet air temperature C Ambient temperature C Outlet air pressure dew point C Dryer outlet air temperature C Facility water flow rate Note 4) (50/60 Hz) m3/h Facility water inlet temperature C Facility water pressure drop Note 5) (50/60 Hz) MPa Cooling...

 Open the catalog to page 7
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-8

Series IDF100F/125F/150F Dimensions IDF100F: Air-cooled type 670 1120 Ventilation air inlet Ventilation direction (When symbol 1 is specified.) Ventilation direction (When no symbol is specified.) Ventilation direction (When symbol 2 is specified.) 335 Ventilation direction (When symbol 3 is specified.) Terminal block for power supply Terminal block for signal Drain tube (O.D. ø10, Length approx. 2 m) (Can also be connected on the other side.) Signal cable outlet (Electric wire diameter ø17 or less) Grommet with membrane Ventilation air inlet Power cable holder (Electric wire diameter ø14 to...

 Open the catalog to page 8
IDF*F Refrigerated Air Dryer, Size 100~150, Standard Inlet Air Temperature-9

Dimensions IDF125F/150F: Air-cooled type A G Ventilation direction (When symbol 3 is specified.) Ventilation air inlet Ventilation direction (When symbol 1 is specified.) Ventilation direction (When no symbol is specified.) Ventilation direction Ball valve Terminal block for power supply Terminal block for signal Ventilation direction (When symbol 2 is specified.) Ventilation direction (When no symbol is specified.) Ventilation direction Heavy duty auto drain Drain tube (O.D. ø10, Length approx. 2 m) (Can also be connected on the other side.) Drain tube for drain pan Power cable holder 64 75...

 Open the catalog to page 9

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. VX3*

    41  Pages

  101. SY3000

    158  Pages

  102. CH(D)2

    175  Pages

  103. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.