Catalog excerpts

IDF*E - 1

An air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.o Effects of moisture on equipment Standard inlet air temperature type IDF lE/F/D Series • Air flow capacity: Increased by up to 40% (SMC comparison) • Power consumption: Reduced by up to 40% (SMC comparison) • Improved corrosion resistance with the stainless steel heat exchanger*1

Open the catalog to page 1
IDF*E - 2

Tolerant of high temperature environment (ambient temperature 45°C), Energy saving design! Air-cooled type can be used at ambient temperature 45°C. Second re-heater helps the heat radiation of the condenser allow use at ambient temperature 45°C. New air dryer Compressed Second re-heater cools air outlet the refrigerant and reduces the load to the condenser. Current air dryer It cannot radiate heat if the ambient temperature is excessive. It is warmed by the second re-heater, preventing condensation of the piping on the outlet side. Second re-heater Compressed air after removing humidity...

Open the catalog to page 2
IDF*E - 3

IDF100F/125F/150F Series Maintenance • Dustproof filter provided as a standard accessory • Only access from front side is required to check electrical equipment and dustproof filter. Dustproof filter Electrical equipment Selection of layout [Air-cooled type] [Water-cooled type] Exhausting direction can be selected from four directions!! Auto drain tube can be connected in two directions, left or right. Facility water piping port can be selected from two directions!! Facility water outlet Left Facility water inlet Facility water outlet Right Facility water inlet Temperature control equipment...

Open the catalog to page 3
IDF*E - 4

Complies with CFC restrictions Refrigerated Air Dryers IDF/IDU Series Contents Standard Inlet Air Temperature Type IDFDE/F/D Series Rated inlet air temperature: 35, 40°C Rated inlet condition Port size High Inlet Air Temperature Type IDUDE Series Model Rated inlet condition p. 14 to 21 Rated inlet air temperature: 55°C Port size p. 25 to 27 Refer to the Web Catalog for air dryer models conforming to international standards (CE and UL).

Open the catalog to page 4
IDF*E - 5

*1 The IDF100F to 150F, 190D, 240D standard types are equipped with a heavy-duty auto drain and a terminal block for remote operation, stop, operating, and error signal. *2 The IDF370D standard type is the water-cooled type with a motor type auto drain. *3 When switching from the previous air dryer and remote operation are required, select the Made to Order (IDF/UDE-D-X256) product. The IDF100F to 150F and 190D to 370D standard types are equipped with a terminal block for remote operation, stop, operating, and error signals. Optional Accessories Description Specific Product Optional O t'...

Open the catalog to page 5
IDF*E - 6

IIDF/IDU Series *1 Values obtained from “Correction Factors” on page 6. Correction factor = 0.82 x 0.96 x 1 x 0.88 = 0.69 Max. coefficient value is 1.5. Correction factor is 1.5 when the calculation result is 1.5 or greater. *1 Values obtained from “Correction Factors” on page 6. Correction factor = 0.95 x 0.93 x 1 x 0.88 = 0.78 Max. coefficient value is 1.5. Correction factor is 1.5 when the calculation result is 1.5 or greater. Calculate the corrected air flow capacity. Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air flow rate e...

Open the catalog to page 6
IDF*E - 7

Model Selection IDF/IDU Series Data ®: Ambient Temperature *1 correction factor is determined to range of 2 to 45°C. Data ©: Outlet Air Pressure Dew Point Outlet air pressure dew point [°C] Outlet air pressure dew point [°C] Outlet air pressure dew point [°C] Data ®: Air Flow Capacity IDF Series * In the case of the Option A (cool compressed air output), the air flow capacity is different. Refer to page 28 for details.

Open the catalog to page 7
IDF*E - 8

Refrigerant R134a (HFC) Standard Inlet Air Temperature IDF□£ Series 1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1 (Inlet air temperature: 35°C, Outlet air pressure dew point: 10°C) How to Order *1 When multiple options are combined, indicate symbols in alphabetical order. However, the following combinations are not possible. • R and S (Because S function is also included in R.) • S and T (Because S function is also included in T.) • The combination of K, L and M is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Voltage symbol...

Open the catalog to page 8
IDF*E - 9

Refrigerated Air Dryer IDF□£ Series Standard Specifications Symbol Model Specifications *1 Air flow capacity under the standard condition (ANR) [20°C, Atmospheric pressure, and 65% Relative humidity] *2 Air flow capacity converted by the compressor intake condition [32°C, Atmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Model Selection (pages 5, 6) for models beyond the rated specifications. *5 When selecting a power supply voltage, refer to the How to Order on page 7. *6...

Open the catalog to page 9
IDF*E - 11

Ventilation direction [200 VAC specification] Terminal block Drain tube (O.D. ø10, length approx. 0.8 m) Ventilation direction Evaporation thermometer Illuminated switch [200 VAC specification] Power cable outlet (ø17) [100 VAC specification] Power cable (Length: approx.1.9 m) Specific Product Optional Precautions Accessories Model Selection

Open the catalog to page 11
IDF*E - 12

Refrigerant R407C (HFC) Standard Inlet Air Temperature IDF IE Series 22E, 37E, 55E, 75E (Inlet air temperature: 35°C (22E, 37E), 40°C (55E, 75E), Outlet air pressure dew point: 10°C) How to Order *1 When multiple options are combined, indicate symbols in alphabetical order. However, the following combinations are not possible. • The combination of K, L and M is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Select the Option L for the 55E and 75E which need moderate pressure. *4 To users who are considering...

Open the catalog to page 12
IDF*E - 13

Standard Specifications Symbol Model Specifications *1 Air flow capacity under the standard condition (ANR) [20°C, Atmospheric pressure, and 65% Relative humidity] *2 Air flow capacity converted by the compressor intake condition [32°C, Atmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Model Selection (pages 5, 6) for models beyond the rated specifications. *5 When selecting a power supply voltage, refer to the How to Order on page 11. *6 These values are reference values...

Open the catalog to page 13

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. SYJ300

    60 Pages

  9. 3000 Series

    272 Pages

  10. MTS8

    23 Pages

  11. CXS-A

    60 Pages

  12. CXSL

    60 Pages

  13. MXQR

    36 Pages

  14. NC(D)Q2-Z

    252 Pages

  15. LEY series

    88 Pages

  16. MXH series

    18 Pages

  17. KQ2

    214 Pages

  18. MXQ series

    198 Pages

  19. CQ2 series

    25 Pages

  20. ISG

    10 Pages

  21. ISE3

    8 Pages

  22. ISE2

    7 Pages

  23. ISE1

    5 Pages

  24. ISA

    59 Pages

  25. IS3000

    2 Pages

  26. IS10/10M/10E

    4 Pages

  27. PSE series

    44 Pages

  28. ISE70/75/75H

    10 Pages

  29. ISE80

    17 Pages

  30. ISE40A

    29 Pages

  31. HED series

    16 Pages

  32. HEC series

    32 Pages

  33. HEB series

    9 Pages

  34. HRG series

    85 Pages

  35. HRZ series

    52 Pages

  36. HRW series

    28 Pages

  37. LQ series

    35 Pages

  38. PA series

    37 Pages

  39. LER series

    62 Pages

  40. LEJ series

    58 Pages

  41. LAT3 series

    24 Pages

  42. LEH series

    103 Pages

  43. CQS series

    59 Pages

  44. CH series

    175 Pages

  45. ARX series

    12 Pages

  46. HRS series

    47 Pages

  47. LES

    59 Pages

  48. MHS

    74 Pages

  49. MHY

    27 Pages

  50. MHC

    27 Pages

  51. MHR

    30 Pages

  52. MHZ series

    78 Pages

  53. MSQ

    37 Pages

  54. MGP

    127 Pages

  55. MXS

    38 Pages

  56. NRB

    10 Pages

  57. MXW

    22 Pages

  58. MHT

    11 Pages

  59. MY3

    54 Pages

  60. CQM

    15 Pages

  61. NCA1

    63 Pages

  62. CM2

    152 Pages

  63. NCM

    91 Pages

  64. NCG

    96 Pages

  65. NCRA1

    5 Pages

  66. CS2

    32 Pages

  67. T/TIA

    1 Pages

  68. KR

    7 Pages

  69. KF

    16 Pages

  70. KQ

    80 Pages

  71. AFF

    80 Pages

  72. AMG

    80 Pages

  73. IDF

    16 Pages

  74. HAA

    3 Pages

  75. ZFA

    14 Pages

  76. ZA

    13 Pages

  77. MHF

    32 Pages

  78. CRB

    44 Pages

  79. D

    117 Pages

  80. RB

    23 Pages

  81. CEP

    44 Pages

  82. rsq

    30 Pages

  83. CLK

    51 Pages

  84. MK

    20 Pages

  85. CLJ

    65 Pages

  86. MGJ

    7 Pages

  87. ZSE30A

    17 Pages

  88. IDFB*E

    89 Pages

  89. ISE10

    16 Pages

  90. ITV1000/2000

    50 Pages

  91. AW

    27 Pages

  92. NVFM200

    12 Pages

  93. NVM100

    32 Pages

  94. LLA*A

    36 Pages

  95. VX3*

    41 Pages

  96. SY3000

    158 Pages

  97. CH(D)2

    175 Pages

  98. LEHZ

    82 Pages

  99. M(D)SUB

    31 Pages

  100. CXSJ

    58 Pages

  101. CY3B

    39 Pages

  102. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages