HRW series - 1

Circulating Fluid Temperature Controller • Temperature stability: More effective energy-saving through use of an inverter pump Inverter type Power consumption 0.5 kWh/h Facility water • Cooling capacity: • Temperature range setting: Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. • Type of circulating fluid: Fluorinated fluids/Ethylene glycol aqueous solution/Clear water, Deionized water Water-cooled Thermo-chiller Series HRW Related Products Technical Data International standards:

Open the catalog to page 1
HRW series - 2

Energy-Saving and Refrigerant-free Existing model Energy-saving and refrigerant-free (Ordinary temperature up to 194°F (90°C)) Facility water circuit Refrigeration circuit Circulating fluid circuit Heat exchanger The water-cooled Thermo-chiller which does not use a compressor (refrigerant-free) is suitable for processes operating from ordinary temperature to 194°F (90°C). The energy-savings shown below can be achieved in comparison with existing models (depending on the conditions). Heat exchanger Power consumption: Max. reduction (SMC comparison) The power consumption can be reduced by...

Open the catalog to page 2
HRW series - 3

High Performance Easy Maintenance (when a load is stable) Circulating fluid inside a Thermo-chiller tank can be recovered automatically. (Recovery volume: 3.2 gal (12 L)) is to to do tion have munica y ou All y the com recover pushutton for eset! b and r Up to 30 kW cooling capacity achieved. Internal pump Option N2 purge port Circulating fluid outlet Circulating pump Heater Existing model Customer’s machine Non-return Heat exchanger valve Facility water inlet 35 Circulating fluid recovery tank Facility water outlet Circulating fluid return port Main tank 20 30 40 50 60 70 Temperature...

Open the catalog to page 3
HRW series - 4

Electrical Resistivity Control Communications ˾ Contact input/output signal ˾ Serial RS-485 communication ˾ Analog communication (Refer to “Options” on page 118.) ˾ DeviceNet communication (Refer to “Options” on page 118.) DI control kit (Refer to “Options” on page 118.) Electrical resistivity of circulating fluid (ethylene glycol aqueous solution and deionized water) can be controlled. Wetted parts adopt the materials compatible for various circulating fluids. (Stainless steel, EPDM, etc.) • Fluorinated fluids: Flourinert™ FC-40 GALDEN® HT200 • 60% ethylene glycol aqueous solution •...

Open the catalog to page 4
HRW series - 5

Application Examples Semiconductor Example: Temperature control of chamber electrode Example: Blood preservation Upper electrode Wafer • X-ray instrument • MRI • Blood preservation equipment Example: Tofu (Bean curd) production Example: Electronic microscope • Etching equipment • Coating equipment • Spatter equipment • Dicing equipment • Cleaning equipment • Tester, etc. Lower electrode Electronic microscope production equipment Water temperature control for forming tofu by mixing the boiled soybean milk and bittern • Electron microscope • X-ray analytical Prevents the distortion caused by...

Open the catalog to page 5
HRW series - 6

Model Selection • Required Cooling Capacity Calculation---- Page 105, 106 • Circulating Fluid Typical Physical I Fluorinated Fluid Type Cooling Capacity/Heating Capacity/ Ethylene Glycol Type Cooling Capacity/Heating Capacity/ Clear/Deionized Water Type Cooling Capacity/Heating Capacity/ • Common Specifications • Circulating Fluid Automatic Recovery---- Page 119 • Optional Accessories • 60% Ethylene Glycol Aqueous

Open the catalog to page 6
HRW series - 7

Model Selection Guide to Model Selection 1. How much is the temperature in degrees centigrade for the circulating fluid? Temperature range which can be set with the Thermo-chiller H: 68 to 195°F (20°C to 90°C) Example) Customer requirement: 122°F (50°C) 2. What kind of the circulating fluids will be used? Relationship between circulating fluid (which can be used with the Thermo-chiller) and temperature Fluorinated fluids: Fluorinert™ FC-40/GALDEN® HT200 60% ethylene glycol aqueous solution Clear water/Deionized water 68°F (20°C) Example) Customer requirement: Clear water 3. How much is the...

Open the catalog to page 7
HRW series - 8

Model Selection Required Cooling Capacity Calculation Example 1: When the heat generation amount in the customer’s machine is known. Heat generation amount Q: 3.5 kW Example 2: When the heat generation amount in the customer’s machine is not known. ∗ Refer to page 107 for the typical physical property values by circulating fluid. Fluorinated fluid Density γ: 1.80 x 103 kg/m3 Specific heat C: 0.23 kcal/kg·°C (at 20°C) ∗ Refer to page 107 for the typical physical property values by circulating fluid. = 3456 W = 3.5 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW...

Open the catalog to page 8
HRW series - 9

Required Cooling Capacity Calculation Example 3. When there is no heat generation, and when cooling the object below a certain temperature and period of time. Cooled substance total volume V Cooling time h Cooling temperature difference ∆T Facility water temperature Circulating fluid Specific heat C: 1.05 x 103 J/(kg·K) (at 50°C) ∗ Refer to page 107 for the typical physical property values by circulating fluid. Cooling capacity = Considering a safety factor of 20%, 2.4 x 1.2 = 2.9 kW (When the circulating fluid temperature is 50°C.) (In this case, selected Thermo-chiller model will be the...

Open the catalog to page 9
HRW series - 10

Model Selection ∗ The below shown are reference values. Please contact circulating fluid supplier for details. Circulating Fluid Typical Physical Property Values Fluorinated Fluids Density γ 3 Specific heat C ([kcal/kg·°C]) Physical property value Temperature Physical property value Temperature Specific heat C: 4.2 x 103 [J/(kg·K)] (1.0 [kcal/kg·°C]) Technical Data Related Products 60% Ethylene Glycol Aqueous Solution

Open the catalog to page 10
HRW series - 11

Fluorinated Fluid Type Fluorinated Fluid Type Cooling capacity Symbol Cooling capacity Analog communication DeviceNet communication NPT fitting Circulating fluid automatic recovery Pump inverter control Temperature range setting H Temperature range setting Pump inverter control None Applicable (Pump inverter type) Specifications (For details, please consult our “Product Specifications” information.) HRW002-H HRW002-HS Ambient temperature/humidity Note 1) Circulating fluid Note 2) Temperature range setting Note 1) Cooling capacity (50/60 Hz common) (kW) Facility water temperature Circulating...

Open the catalog to page 11

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. LQ series

    35 Pages

  38. PA series

    37 Pages

  39. LER series

    62 Pages

  40. LEJ series

    58 Pages

  41. LAT3 series

    24 Pages

  42. LEH series

    103 Pages

  43. CQS series

    59 Pages

  44. CH series

    175 Pages

  45. ARX series

    12 Pages

  46. HRS series

    47 Pages

  47. LES

    59 Pages

  48. MHS

    74 Pages

  49. MHY

    27 Pages

  50. MHC

    27 Pages

  51. MHR

    30 Pages

  52. MHZ series

    78 Pages

  53. MSQ

    37 Pages

  54. MGP

    127 Pages

  55. MXS

    38 Pages

  56. NRB

    10 Pages

  57. MXW

    22 Pages

  58. MHT

    11 Pages

  59. MY3

    54 Pages

  60. CQM

    15 Pages

  61. NCA1

    63 Pages

  62. CM2

    152 Pages

  63. NCM

    91 Pages

  64. NCG

    96 Pages

  65. NCRA1

    5 Pages

  66. CS2

    32 Pages

  67. T/TIA

    1 Pages

  68. KR

    7 Pages

  69. KF

    16 Pages

  70. KQ

    80 Pages

  71. AFF

    80 Pages

  72. AMG

    80 Pages

  73. IDF

    16 Pages

  74. HAA

    3 Pages

  75. ZFA

    14 Pages

  76. ZA

    13 Pages

  77. MHF

    32 Pages

  78. CRB

    44 Pages

  79. D

    117 Pages

  80. RB

    23 Pages

  81. CEP

    44 Pages

  82. rsq

    30 Pages

  83. CLK

    51 Pages

  84. MK

    20 Pages

  85. CLJ

    65 Pages

  86. MGJ

    7 Pages

  87. ZSE30A

    17 Pages

  88. IDFB*E

    89 Pages

  89. ISE10

    16 Pages

  90. ITV1000/2000

    50 Pages

  91. AW

    27 Pages

  92. NVFM200

    12 Pages

  93. NVM100

    32 Pages

  94. LLA*A

    36 Pages

  95. VX3*

    41 Pages

  96. SY3000

    158 Pages

  97. CH(D)2

    175 Pages

  98. LEHZ

    82 Pages

  99. M(D)SUB

    31 Pages

  100. CXSJ

    58 Pages

  101. CY3B

    39 Pages

  102. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages