video corpo
cad

HRW series
1 /28Pages

HRW series

HRW series
1 /28Pages

Catalog excerpts

HRW series-1

Circulating Fluid Temperature Controller • Temperature stability: More effective energy-saving through use of an inverter pump Inverter type Power consumption 0.5 kWh/h Facility water • Cooling capacity: • Temperature range setting: Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. • Type of circulating fluid: Fluorinated fluids/Ethylene glycol aqueous solution/Clear water, Deionized water Water-cooled Thermo-chiller Series HRW Related Products Technical Data International standards:

 Open the catalog to page 1
HRW series-2

Energy-Saving and Refrigerant-free Existing model Energy-saving and refrigerant-free (Ordinary temperature up to 194°F (90°C)) Facility water circuit Refrigeration circuit Circulating fluid circuit Heat exchanger The water-cooled Thermo-chiller which does not use a compressor (refrigerant-free) is suitable for processes operating from ordinary temperature to 194°F (90°C). The energy-savings shown below can be achieved in comparison with existing models (depending on the conditions). Heat exchanger Power consumption: Max. reduction (SMC comparison) The power consumption can be reduced by direct...

 Open the catalog to page 2
HRW series-3

High Performance Easy Maintenance (when a load is stable) Circulating fluid inside a Thermo-chiller tank can be recovered automatically. (Recovery volume: 3.2 gal (12 L)) is to to do tion have munica y ou All y the com recover pushutton for eset! b and r Up to 30 kW cooling capacity achieved. Internal pump Option N2 purge port Circulating fluid outlet Circulating pump Heater Existing model Customer’s machine Non-return Heat exchanger valve Facility water inlet 35 Circulating fluid recovery tank Facility water outlet Circulating fluid return port Main tank 20 30 40 50 60 70 Temperature difference...

 Open the catalog to page 3
HRW series-4

Electrical Resistivity Control Communications ˾ Contact input/output signal ˾ Serial RS-485 communication ˾ Analog communication (Refer to “Options” on page 118.) ˾ DeviceNet communication (Refer to “Options” on page 118.) DI control kit (Refer to “Options” on page 118.) Electrical resistivity of circulating fluid (ethylene glycol aqueous solution and deionized water) can be controlled. Wetted parts adopt the materials compatible for various circulating fluids. (Stainless steel, EPDM, etc.) • Fluorinated fluids: Flourinert™ FC-40 GALDEN® HT200 • 60% ethylene glycol aqueous solution • Deionized...

 Open the catalog to page 4
HRW series-5

Application Examples Semiconductor Example: Temperature control of chamber electrode Example: Blood preservation Upper electrode Wafer • X-ray instrument • MRI • Blood preservation equipment Example: Tofu (Bean curd) production Example: Electronic microscope • Etching equipment • Coating equipment • Spatter equipment • Dicing equipment • Cleaning equipment • Tester, etc. Lower electrode Electronic microscope production equipment Water temperature control for forming tofu by mixing the boiled soybean milk and bittern • Electron microscope • X-ray analytical Prevents the distortion caused by the...

 Open the catalog to page 5
HRW series-6

Model Selection • Required Cooling Capacity Calculation---- Page 105, 106 • Circulating Fluid Typical Physical I Fluorinated Fluid Type Cooling Capacity/Heating Capacity/ Ethylene Glycol Type Cooling Capacity/Heating Capacity/ Clear/Deionized Water Type Cooling Capacity/Heating Capacity/ • Common Specifications • Circulating Fluid Automatic Recovery---- Page 119 • Optional Accessories • 60% Ethylene Glycol Aqueous

 Open the catalog to page 6
HRW series-7

Model Selection Guide to Model Selection 1. How much is the temperature in degrees centigrade for the circulating fluid? Temperature range which can be set with the Thermo-chiller H: 68 to 195°F (20°C to 90°C) Example) Customer requirement: 122°F (50°C) 2. What kind of the circulating fluids will be used? Relationship between circulating fluid (which can be used with the Thermo-chiller) and temperature Fluorinated fluids: Fluorinert™ FC-40/GALDEN® HT200 60% ethylene glycol aqueous solution Clear water/Deionized water 68°F (20°C) Example) Customer requirement: Clear water 3. How much is the temperature...

 Open the catalog to page 7
HRW series-8

Model Selection Required Cooling Capacity Calculation Example 1: When the heat generation amount in the customer’s machine is known. Heat generation amount Q: 3.5 kW Example 2: When the heat generation amount in the customer’s machine is not known. ∗ Refer to page 107 for the typical physical property values by circulating fluid. Fluorinated fluid Density γ: 1.80 x 103 kg/m3 Specific heat C: 0.23 kcal/kg·°C (at 20°C) ∗ Refer to page 107 for the typical physical property values by circulating fluid. = 3456 W = 3.5 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW Cooling...

 Open the catalog to page 8
HRW series-9

Required Cooling Capacity Calculation Example 3. When there is no heat generation, and when cooling the object below a certain temperature and period of time. Cooled substance total volume V Cooling time h Cooling temperature difference ∆T Facility water temperature Circulating fluid Specific heat C: 1.05 x 103 J/(kg·K) (at 50°C) ∗ Refer to page 107 for the typical physical property values by circulating fluid. Cooling capacity = Considering a safety factor of 20%, 2.4 x 1.2 = 2.9 kW (When the circulating fluid temperature is 50°C.) (In this case, selected Thermo-chiller model will be the HRW008-H.)...

 Open the catalog to page 9
HRW series-10

Model Selection ∗ The below shown are reference values. Please contact circulating fluid supplier for details. Circulating Fluid Typical Physical Property Values Fluorinated Fluids Density γ 3 Specific heat C ([kcal/kg·°C]) Physical property value Temperature Physical property value Temperature Specific heat C: 4.2 x 103 [J/(kg·K)] (1.0 [kcal/kg·°C]) Technical Data Related Products 60% Ethylene Glycol Aqueous Solution

 Open the catalog to page 10
HRW series-11

Fluorinated Fluid Type Fluorinated Fluid Type Cooling capacity Symbol Cooling capacity Analog communication DeviceNet communication NPT fitting Circulating fluid automatic recovery Pump inverter control Temperature range setting H Temperature range setting Pump inverter control None Applicable (Pump inverter type) Specifications (For details, please consult our “Product Specifications” information.) HRW002-H HRW002-HS Ambient temperature/humidity Note 1) Circulating fluid Note 2) Temperature range setting Note 1) Cooling capacity (50/60 Hz common) (kW) Facility water temperature Circulating fluid...

 Open the catalog to page 11

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. LQ series

    35  Pages

  42. PA series

    37  Pages

  43. LER series

    62  Pages

  44. LEJ series

    58  Pages

  45. LAT3 series

    24  Pages

  46. LEH series

    103  Pages

  47. CQS series

    59  Pages

  48. CH series

    175  Pages

  49. ARX series

    12  Pages

  50. HRS series

    47  Pages

  51. LES

    59  Pages

  52. MHS

    74  Pages

  53. MHY

    27  Pages

  54. MHC

    27  Pages

  55. MHR

    30  Pages

  56. MHZ series

    78  Pages

  57. MSQ

    37  Pages

  58. MGP

    127  Pages

  59. MXS

    38  Pages

  60. NRB

    10  Pages

  61. MXW

    22  Pages

  62. MHT

    11  Pages

  63. MY3

    54  Pages

  64. CQM

    15  Pages

  65. NCA1

    63  Pages

  66. CM2

    152  Pages

  67. NCM

    91  Pages

  68. NCG

    96  Pages

  69. NCRA1

    5  Pages

  70. CS2

    32  Pages

  71. T/TIA

    1  Page

  72. KR

    7  Pages

  73. KF

    16  Pages

  74. KQ

    80  Pages

  75. AFF

    80  Pages

  76. AMG

    80  Pages

  77. IDF

    16  Pages

  78. HAA

    3  Pages

  79. ZFA

    14  Pages

  80. ZA

    13  Pages

  81. MHF

    32  Pages

  82. CRB

    44  Pages

  83. D

    117  Pages

  84. RB

    23  Pages

  85. CEP

    44  Pages

  86. rsq

    30  Pages

  87. CLK

    51  Pages

  88. MK

    20  Pages

  89. CLJ

    65  Pages

  90. MGJ

    7  Pages

  91. ZSE30A

    17  Pages

  92. IDFB*E

    89  Pages

  93. ISE10

    16  Pages

  94. ITV1000/2000

    50  Pages

  95. AW

    27  Pages

  96. NVFM200

    12  Pages

  97. NVM100

    32  Pages

  98. LLA*A

    36  Pages

  99. VX3*

    41  Pages

  100. SY3000

    158  Pages

  101. CH(D)2

    175  Pages

  102. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.