HRS series
64Pages

{{requestButtons}}

Catalog excerpts

HRS series - 1

The models IDF1E to 11E and IDU3E to 6E have been revised. For details, refer to catalog no. ES30-8A. Similar updating for other IDF/IDU models is scheduled to follow shortly. HA AT ID AMG AFF AM >

Open the catalog to page 1
HRS series - 4

Quiet operation allows indoor use in locations such as dental offices, etc. Coaxial copper piping design prevents rust formation. Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60 C.IDU3D to 6D: 60 а CIDU8D to 37C1: 55 CIDU55C, 75C: 50 > C System efficiency is improved by using a high performance heat exchanger. > Small series: R134aMedium series: R22 Large series: R407C >

Open the catalog to page 4
HRS series - 6

The procedure for selecting the optimum model under the followingconditions is shown below.Inlet air temperature 55 The procedure for selecting the optimum model under the followingconditions is shown below.Inlet air temperature 40 ConditionCondition 緰 COutlet air pressure dew point 10 COutlet air pressure dew point 10 а CAmbient temperature 35 CAmbient temperature 35 а CInlet air pressure 0.7MPa Air flow 350 CInlet air pressure 0.5MPa Air flow 1200 > /min (ANR)Power supply frequency 50Hz > /min (ANR)Power supply frequency 60Hz > 1234 1234 B -1 = 0.95 based on conditions , and C = 0.90...

Open the catalog to page 6
HRS series - 11

Compressedair inletCompressedair outlet600(445)(85) 220(315)(60)(141) [200 to 240 VAC specification] (68) 45065 Power cord outlet C > Ventilationair outlet Ventilation air inlet > (B) A(159) D 250278 Illuminated switchEvaporation thermometer[200 to 240VACspecification]Terminal block [100VAC specification]Power cordDrain portRc 1/4 4-13 > Auto drain is packed together with air dryer. (Some assembly is required.) : Power source 220 to 240VAC Model Port sizeR 1/2R 3/4A710810B760860C560 551 D240 75 >

Open the catalog to page 11
HRS series - 18

Compressed air outletRc 3/8 [200 to 240VAC specification]Terminal blockLDrain tube > G Ventilation air inlet [200 to 240VAC specification]Power cord outlet Illuminated switchInspection grill K A > C F [100VAC specification]Power cord B NM Ventilation direction Ventilation direction (900) Compressed air inletRc 3/8ED > J H Compressed air inletRc 3/8170 31 > Illuminated switch [100VAC specification]Power cord Inspection grill (900) 242Compressed air outletRc 3/8 [200 to 240VAC specification]Terminal block 481 63336Drain tube Ventilation direction Ventilation direction 4-13 > 13 Ventilation...

Open the catalog to page 18
HRS series - 19

Compressedair inletCompressedair outlet600 410 (456) 120 (72)Ventilation air inlet 220 (315)(60)(141) (68) 450 65(Condenser) Ventilation air outlet [200 to 240VAC specification] Terminal block Ventilationdirection Ventilation direction > (570)520(159) [100VAC specification] > 240 75 Power cord outletDrain portRc 1/4 250 278 Illuminated switchEvaporation thermometer [200 to 240VAC specification] 4-13 Power cord outlet560 551 ( ): Dimension within bracket is for air dryer with option A, with cool compressed air output.Air inlet and outlet are reversed for air dryer with option A, with cool...

Open the catalog to page 19
HRS series - 23

Symbol Voltage Note 2) Possible to combine 2 options.When requiring 3 options or more, it is made to order. 37 89 200/200 to 220VAC (50/60Hz) Threephase 380VAC (50Hz)415VAC (50Hz)Built-in transformer R407C120kW150kW 190kW 240kW OptionWith motoroperated auto drainWithcircuit breaker CMR W ModelAircompressor Refrigerant Note 1) Select one applicable voltage. Water-cooled condenserWithanti- corrosive treatment 120D150D 190D 240D Model 3789 Voltage 120D150D 190D 240D 37 8 9 > Model Aircompressor Refrigerant Withcircuitbraker With Heavyduty autodrain Model370B Symbol ModelSizeOption Symbol...

Open the catalog to page 23
HRS series - 25

Ventilation direction K Port size(JIS 10K) A(80) G DVentilation directionCompressedair inletPower supply cable entryIH Ventilation air inlet Ventilation direction C Compressedair outlet Anchor bolt hole Rc 1/2 B100 J 200 FE 650 4-20 Model Port size A B C D E F G H I J K IDF120DIDF150DIDF190D IDF240D JIS 10K 2B 1/2 Flange 650750770 120015101550 130013201640 325375385 470480703 600600730 600700700 660800800 330355355 365427592 JIS 10K 3B FlangeJIS 10K 3B FlangeJIS 10K 4B Flange 780880900 > Auto drain is packed together with air dryer. (Some assembly is required.) Compressedair...

Open the catalog to page 25
HRS series - 27

Option symbol W: Water cooled condenser (IDF37C1 to 240D) Option symbol This option can be used where the ambient temperature is high (Max. 43 C), and does not reduce air flow capacity. It is also possible to use this option in an enclosed environment to prevent increasing of the surrounding temperature. IDF370B standard. Model > /min > Note1) 621/2BShell & coil system 821/2B 203 3/4B 505 1B 657.5 1B 807.5 1B 907.5 1BPressure auto feed valve > A 53 Cooling tower capacity RT > Note 2) B Water flow regulator Connection bore on water side (union) Model > Power cord outletPower cord outlet...

Open the catalog to page 27
HRS series - 33

Avoid locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is more than 85%)Օ Avoid exposure to direct sunlight. Avoid dusty or corrosive environments.If it is used in the above environments, select option C (with anti-corrosivetreatment). Օ Allow ample space around the air dryer. <100VAC> Insert the power supply plug into an exclusive 100VAC power outlet.Օ Install a circuit breaker (10A) ∗ Use a circuit breaker having a sensitivity current of 30mA or less and a rated current of 10A. ∗ at the power supply. Be sure to ground the power...

Open the catalog to page 33
HRS series - 34

When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. When compressed air temperature is too highՕ When compressed air flow rate is too high When ambient temperature is too high (40 > Please waitthree minutes! հ C or higher) When power supply is beyond rated voltage by ձ 10% When ventilation port is obstructed by a wall or clogged with dustUse an air compressor of 100 > /min or greater air delivery with IDF2D to 4D/IDU3D, 4D, and 300 A crank case heater is installed on IDF370B. Energize the crank case...

Open the catalog to page 34
HRS series - 35

These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger" . To ensure safety, be sure to observe ISO 4414 > Note 1) , JIS B 8370 > Note 2) and other safety practices. > Operator error could result in injury or equipment damage. Operator error could result in serious injury or loss of life. In extreme conditions, there is a possible result of serious injury or loss of life. Note 1)ISO 4414: Pneumatic fluid power--General rules relating to systems.Note...

Open the catalog to page 35

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. LES

    59 Pages

  48. MHS

    74 Pages

  49. MHY

    27 Pages

  50. MHC

    27 Pages

  51. MHR

    30 Pages

  52. MHZ series

    78 Pages

  53. MSQ

    37 Pages

  54. MGP

    127 Pages

  55. MXS

    38 Pages

  56. NRB

    10 Pages

  57. MXW

    22 Pages

  58. MHT

    11 Pages

  59. MY3

    54 Pages

  60. CQM

    15 Pages

  61. NCA1

    63 Pages

  62. CM2

    152 Pages

  63. NCM

    91 Pages

  64. NCG

    96 Pages

  65. NCRA1

    5 Pages

  66. CS2

    32 Pages

  67. T/TIA

    1 Pages

  68. KR

    7 Pages

  69. KF

    16 Pages

  70. KQ

    80 Pages

  71. AFF

    80 Pages

  72. AMG

    80 Pages

  73. IDF

    16 Pages

  74. HAA

    3 Pages

  75. ZFA

    14 Pages

  76. ZA

    13 Pages

  77. MHF

    32 Pages

  78. CRB

    44 Pages

  79. D

    117 Pages

  80. RB

    23 Pages

  81. CEP

    44 Pages

  82. rsq

    30 Pages

  83. CLK

    51 Pages

  84. MK

    20 Pages

  85. CLJ

    65 Pages

  86. MGJ

    7 Pages

  87. ZSE30A

    17 Pages

  88. IDFB*E

    89 Pages

  89. ISE10

    16 Pages

  90. ITV1000/2000

    50 Pages

  91. AW

    27 Pages

  92. NVFM200

    12 Pages

  93. NVM100

    32 Pages

  94. LLA*A

    36 Pages

  95. VX3*

    41 Pages

  96. SY3000

    158 Pages

  97. CH(D)2

    175 Pages

  98. LEHZ

    82 Pages

  99. M(D)SUB

    31 Pages

  100. CXSJ

    58 Pages

  101. CY3B

    39 Pages

  102. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages