Catalog excerpts
The models IDF1E to 11E and IDU3E to 6E have been revised. For details, refer to catalog no. ES30-8A. Similar updating for other IDF/IDU models is scheduled to follow shortly. HA AT ID AMG AFF AM >
Open the catalog to page 1Quiet operation allows indoor use in locations such as dental offices, etc. Coaxial copper piping design prevents rust formation. Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60 C.IDU3D to 6D: 60 а CIDU8D to 37C1: 55 CIDU55C, 75C: 50 > C System efficiency is improved by using a high performance heat exchanger. > Small series: R134aMedium series: R22 Large series: R407C >
Open the catalog to page 4The procedure for selecting the optimum model under the followingconditions is shown below.Inlet air temperature 55 The procedure for selecting the optimum model under the followingconditions is shown below.Inlet air temperature 40 ConditionCondition 緰 COutlet air pressure dew point 10 COutlet air pressure dew point 10 а CAmbient temperature 35 CAmbient temperature 35 а CInlet air pressure 0.7MPa Air flow 350 CInlet air pressure 0.5MPa Air flow 1200 > /min (ANR)Power supply frequency 50Hz > /min (ANR)Power supply frequency 60Hz > 1234 1234 B -1 = 0.95 based on conditions , and C = 0.90...
Open the catalog to page 6Compressedair inletCompressedair outlet600(445)(85) 220(315)(60)(141) [200 to 240 VAC specification] (68) 45065 Power cord outlet C > Ventilationair outlet Ventilation air inlet > (B) A(159) D 250278 Illuminated switchEvaporation thermometer[200 to 240VACspecification]Terminal block [100VAC specification]Power cordDrain portRc 1/4 4-13 > Auto drain is packed together with air dryer. (Some assembly is required.) : Power source 220 to 240VAC Model Port sizeR 1/2R 3/4A710810B760860C560 551 D240 75 >
Open the catalog to page 11Compressed air outletRc 3/8 [200 to 240VAC specification]Terminal blockLDrain tube > G Ventilation air inlet [200 to 240VAC specification]Power cord outlet Illuminated switchInspection grill K A > C F [100VAC specification]Power cord B NM Ventilation direction Ventilation direction (900) Compressed air inletRc 3/8ED > J H Compressed air inletRc 3/8170 31 > Illuminated switch [100VAC specification]Power cord Inspection grill (900) 242Compressed air outletRc 3/8 [200 to 240VAC specification]Terminal block 481 63336Drain tube Ventilation direction Ventilation direction 4-13 > 13 Ventilation...
Open the catalog to page 18Compressedair inletCompressedair outlet600 410 (456) 120 (72)Ventilation air inlet 220 (315)(60)(141) (68) 450 65(Condenser) Ventilation air outlet [200 to 240VAC specification] Terminal block Ventilationdirection Ventilation direction > (570)520(159) [100VAC specification] > 240 75 Power cord outletDrain portRc 1/4 250 278 Illuminated switchEvaporation thermometer [200 to 240VAC specification] 4-13 Power cord outlet560 551 ( ): Dimension within bracket is for air dryer with option A, with cool compressed air output.Air inlet and outlet are reversed for air dryer with option A, with cool...
Open the catalog to page 19Symbol Voltage Note 2) Possible to combine 2 options.When requiring 3 options or more, it is made to order. 37 89 200/200 to 220VAC (50/60Hz) Threephase 380VAC (50Hz)415VAC (50Hz)Built-in transformer R407C120kW150kW 190kW 240kW OptionWith motoroperated auto drainWithcircuit breaker CMR W ModelAircompressor Refrigerant Note 1) Select one applicable voltage. Water-cooled condenserWithanti- corrosive treatment 120D150D 190D 240D Model 3789 Voltage 120D150D 190D 240D 37 8 9 > Model Aircompressor Refrigerant Withcircuitbraker With Heavyduty autodrain Model370B Symbol ModelSizeOption Symbol...
Open the catalog to page 23Ventilation direction K Port size(JIS 10K) A(80) G DVentilation directionCompressedair inletPower supply cable entryIH Ventilation air inlet Ventilation direction C Compressedair outlet Anchor bolt hole Rc 1/2 B100 J 200 FE 650 4-20 Model Port size A B C D E F G H I J K IDF120DIDF150DIDF190D IDF240D JIS 10K 2B 1/2 Flange 650750770 120015101550 130013201640 325375385 470480703 600600730 600700700 660800800 330355355 365427592 JIS 10K 3B FlangeJIS 10K 3B FlangeJIS 10K 4B Flange 780880900 > Auto drain is packed together with air dryer. (Some assembly is required.) Compressedair...
Open the catalog to page 25Option symbol W: Water cooled condenser (IDF37C1 to 240D) Option symbol This option can be used where the ambient temperature is high (Max. 43 C), and does not reduce air flow capacity. It is also possible to use this option in an enclosed environment to prevent increasing of the surrounding temperature. IDF370B standard. Model > /min > Note1) 621/2BShell & coil system 821/2B 203 3/4B 505 1B 657.5 1B 807.5 1B 907.5 1BPressure auto feed valve > A 53 Cooling tower capacity RT > Note 2) B Water flow regulator Connection bore on water side (union) Model > Power cord outletPower cord outlet...
Open the catalog to page 27Avoid locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is more than 85%)Օ Avoid exposure to direct sunlight. Avoid dusty or corrosive environments.If it is used in the above environments, select option C (with anti-corrosivetreatment). Օ Allow ample space around the air dryer. <100VAC> Insert the power supply plug into an exclusive 100VAC power outlet.Օ Install a circuit breaker (10A) ∗ Use a circuit breaker having a sensitivity current of 30mA or less and a rated current of 10A. ∗ at the power supply. Be sure to ground the power...
Open the catalog to page 33When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. When compressed air temperature is too highՕ When compressed air flow rate is too high When ambient temperature is too high (40 > Please waitthree minutes! հ C or higher) When power supply is beyond rated voltage by ձ 10% When ventilation port is obstructed by a wall or clogged with dustUse an air compressor of 100 > /min or greater air delivery with IDF2D to 4D/IDU3D, 4D, and 300 A crank case heater is installed on IDF370B. Energize the crank case...
Open the catalog to page 34These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger" . To ensure safety, be sure to observe ISO 4414 > Note 1) , JIS B 8370 > Note 2) and other safety practices. > Operator error could result in injury or equipment damage. Operator error could result in serious injury or loss of life. In extreme conditions, there is a possible result of serious injury or loss of life. Note 1)ISO 4414: Pneumatic fluid power--General rules relating to systems.Note...
Open the catalog to page 35All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages