HRS series
1 /64Pages

HRS series

HRS series
1 /64Pages

Catalog excerpts

HRS series-1

The models IDF1E to 11E and IDU3E to 6E have been revised. For details, refer to catalog no. ES30-8A. Similar updating for other IDF/IDU models is scheduled to follow shortly. HA AT ID AMG AFF AM >

 Open the catalog to page 1
HRS series-4

Quiet operation allows indoor use in locations such as dental offices, etc. Coaxial copper piping design prevents rust formation. Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60 C.IDU3D to 6D: 60 а CIDU8D to 37C1: 55 CIDU55C, 75C: 50 > C System efficiency is improved by using a high performance heat exchanger. > Small series: R134aMedium series: R22 Large series: R407C >

 Open the catalog to page 4
HRS series-6

The procedure for selecting the optimum model under the followingconditions is shown below.Inlet air temperature 55 The procedure for selecting the optimum model under the followingconditions is shown below.Inlet air temperature 40 ConditionCondition 緰 COutlet air pressure dew point 10 COutlet air pressure dew point 10 а CAmbient temperature 35 CAmbient temperature 35 а CInlet air pressure 0.7MPa Air flow 350 CInlet air pressure 0.5MPa Air flow 1200 > /min (ANR)Power supply frequency 50Hz > /min (ANR)Power supply frequency 60Hz > 1234 1234 B -1 = 0.95 based on conditions , and C = 0.90 based...

 Open the catalog to page 6
HRS series-11

Compressedair inletCompressedair outlet600(445)(85) 220(315)(60)(141) [200 to 240 VAC specification] (68) 45065 Power cord outlet C > Ventilationair outlet Ventilation air inlet > (B) A(159) D 250278 Illuminated switchEvaporation thermometer[200 to 240VACspecification]Terminal block [100VAC specification]Power cordDrain portRc 1/4 4-13 > Auto drain is packed together with air dryer. (Some assembly is required.) : Power source 220 to 240VAC Model Port sizeR 1/2R 3/4A710810B760860C560 551 D240 75 >

 Open the catalog to page 11
HRS series-18

Compressed air outletRc 3/8 [200 to 240VAC specification]Terminal blockLDrain tube > G Ventilation air inlet [200 to 240VAC specification]Power cord outlet Illuminated switchInspection grill K A > C F [100VAC specification]Power cord B NM Ventilation direction Ventilation direction (900) Compressed air inletRc 3/8ED > J H Compressed air inletRc 3/8170 31 > Illuminated switch [100VAC specification]Power cord Inspection grill (900) 242Compressed air outletRc 3/8 [200 to 240VAC specification]Terminal block 481 63336Drain tube Ventilation direction Ventilation direction 4-13 > 13 Ventilation air...

 Open the catalog to page 18
HRS series-19

Compressedair inletCompressedair outlet600 410 (456) 120 (72)Ventilation air inlet 220 (315)(60)(141) (68) 450 65(Condenser) Ventilation air outlet [200 to 240VAC specification] Terminal block Ventilationdirection Ventilation direction > (570)520(159) [100VAC specification] > 240 75 Power cord outletDrain portRc 1/4 250 278 Illuminated switchEvaporation thermometer [200 to 240VAC specification] 4-13 Power cord outlet560 551 ( ): Dimension within bracket is for air dryer with option A, with cool compressed air output.Air inlet and outlet are reversed for air dryer with option A, with cool compressed...

 Open the catalog to page 19
HRS series-23

Symbol Voltage Note 2) Possible to combine 2 options.When requiring 3 options or more, it is made to order. 37 89 200/200 to 220VAC (50/60Hz) Threephase 380VAC (50Hz)415VAC (50Hz)Built-in transformer R407C120kW150kW 190kW 240kW OptionWith motoroperated auto drainWithcircuit breaker CMR W ModelAircompressor Refrigerant Note 1) Select one applicable voltage. Water-cooled condenserWithanti- corrosive treatment 120D150D 190D 240D Model 3789 Voltage 120D150D 190D 240D 37 8 9 > Model Aircompressor Refrigerant Withcircuitbraker With Heavyduty autodrain Model370B Symbol ModelSizeOption Symbol Voltage...

 Open the catalog to page 23
HRS series-25

Ventilation direction K Port size(JIS 10K) A(80) G DVentilation directionCompressedair inletPower supply cable entryIH Ventilation air inlet Ventilation direction C Compressedair outlet Anchor bolt hole Rc 1/2 B100 J 200 FE 650 4-20 Model Port size A B C D E F G H I J K IDF120DIDF150DIDF190D IDF240D JIS 10K 2B 1/2 Flange 650750770 120015101550 130013201640 325375385 470480703 600600730 600700700 660800800 330355355 365427592 JIS 10K 3B FlangeJIS 10K 3B FlangeJIS 10K 4B Flange 780880900 > Auto drain is packed together with air dryer. (Some assembly is required.) Compressedair inletCompressedair...

 Open the catalog to page 25
HRS series-27

Option symbol W: Water cooled condenser (IDF37C1 to 240D) Option symbol This option can be used where the ambient temperature is high (Max. 43 C), and does not reduce air flow capacity. It is also possible to use this option in an enclosed environment to prevent increasing of the surrounding temperature. IDF370B standard. Model > /min > Note1) 621/2BShell & coil system 821/2B 203 3/4B 505 1B 657.5 1B 807.5 1B 907.5 1BPressure auto feed valve > A 53 Cooling tower capacity RT > Note 2) B Water flow regulator Connection bore on water side (union) Model > Power cord outletPower cord outlet (и17)Grommet...

 Open the catalog to page 27
HRS series-33

Avoid locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is more than 85%)Օ Avoid exposure to direct sunlight. Avoid dusty or corrosive environments.If it is used in the above environments, select option C (with anti-corrosivetreatment). Օ Allow ample space around the air dryer. <100VAC> Insert the power supply plug into an exclusive 100VAC power outlet.Օ Install a circuit breaker (10A) ∗ Use a circuit breaker having a sensitivity current of 30mA or less and a rated current of 10A. ∗ at the power supply. Be sure to ground the power supply...

 Open the catalog to page 33
HRS series-34

When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. When compressed air temperature is too highՕ When compressed air flow rate is too high When ambient temperature is too high (40 > Please waitthree minutes! հ C or higher) When power supply is beyond rated voltage by ձ 10% When ventilation port is obstructed by a wall or clogged with dustUse an air compressor of 100 > /min or greater air delivery with IDF2D to 4D/IDU3D, 4D, and 300 A crank case heater is installed on IDF370B. Energize the crank case heater...

 Open the catalog to page 34

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. LES

    59  Pages

  52. MHS

    74  Pages

  53. MHY

    27  Pages

  54. MHC

    27  Pages

  55. MHR

    30  Pages

  56. MHZ series

    78  Pages

  57. MSQ

    37  Pages

  58. MGP

    127  Pages

  59. MXS

    38  Pages

  60. NRB

    10  Pages

  61. MXW

    22  Pages

  62. MHT

    11  Pages

  63. MY3

    54  Pages

  64. CQM

    15  Pages

  65. NCA1

    63  Pages

  66. CM2

    152  Pages

  67. NCM

    91  Pages

  68. NCG

    96  Pages

  69. NCRA1

    5  Pages

  70. CS2

    32  Pages

  71. T/TIA

    1  Page

  72. KR

    7  Pages

  73. KF

    16  Pages

  74. KQ

    80  Pages

  75. AFF

    80  Pages

  76. AMG

    80  Pages

  77. IDF

    16  Pages

  78. HAA

    3  Pages

  79. ZFA

    14  Pages

  80. ZA

    13  Pages

  81. MHF

    32  Pages

  82. CRB

    44  Pages

  83. D

    117  Pages

  84. RB

    23  Pages

  85. CEP

    44  Pages

  86. rsq

    30  Pages

  87. CLK

    51  Pages

  88. MK

    20  Pages

  89. CLJ

    65  Pages

  90. MGJ

    7  Pages

  91. ZSE30A

    17  Pages

  92. IDFB*E

    89  Pages

  93. ISE10

    16  Pages

  94. ITV1000/2000

    50  Pages

  95. AW

    27  Pages

  96. NVFM200

    12  Pages

  97. NVM100

    32  Pages

  98. LLA*A

    36  Pages

  99. VX3*

    41  Pages

  100. SY3000

    158  Pages

  101. CH(D)2

    175  Pages

  102. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.