Peltier-Type Temperature Control System for Chemicals Fluororesin heat exchanger allows direct temperature control for chemicals!! Chemical Thermo-con Temperature controller Peltier device (Thermo-module) Type of circulating fluid • Deionized water • Hydrofluoric acid • Ammonia hydrogen peroxide solution, etc. Chemical fluid tank or chemical bath Fluororesin heat exchanger Chemical Thermo-con Facility water Industry-leading withstand pressure 51 psi !! Cooling capacity (with water): Related Products International standards: SEMI Standard S2-0706, F47-0706 Environment friendly: 50° to 140°F(10° to 60°C) Temperature stability: ±0.18°F (±0.1°C) Operating temperature range: Technical Data With leakage detection function
Open the catalog to page 1Allows direct control of chemical temperature. PFA wetted parts material prevents contamination from metal ion elution. No need for a tube-type heat exchanger. No need for a tubeDirect temperature control Indirect temperature control type heat exchanger. Can directly control temperature of chemicals. Chemical fluid tank Chemical fluid tank Temperature controller Tube type Pump heat exchanger Fluororesin heat exchanger Chemical Thermo-con Compact and Light Self-developed heat exchanger matched to the configuration of the Peltier device (Thermo-module). Compact and light W Existing model Heat Exchanger...
Open the catalog to page 2Principle of Peltier Device (Thermo-module, Thermoelectric device) The Peltier device (thermo-module, thermoelectric device) is plate-shape solid state element with P-type, N-type semiconductor arrayed alternately. When direct current is supplied to the element, heat moves from one surface to another along with electron flow in N-type semiconductor and electron hole in P-type semiconductor. As a result of the heat move, one surface of the element absorbs heat and decrease temperature. And other surface heats up. When the DC current is switched to reverse direction, the heat move will also be...
Open the catalog to page 3Model Selection Guide to Model Selection Example 1: When the heat generation amount in the customer’s machine is known. Heat generation amount Q: 400 W (at 77°F (25°C)) Cooling capacity = Considering a safety factor of 20%, select 400 W x 1.2 = 480 W (at 77°F (25°C)) or more. Example 2: When the heat generation amount in the customer’s machine is not known. Obtain the temperature difference between inlet and outlet by circulating the circulating fluid inside the customer’s machine. Customer’s machine Flow rate gauge L : Unknown : 1.0°C (1.0 K) : 20°C (293.15 K) : 21°C (294.15 K) : 7 L/min : Water...
Open the catalog to page 4Chemical Thermo-con How to Order Part number of set (Temperature controller + Heat exchanger) Note) The model numbers of the temperature controller and heat exchanger are printed respectively on the product name label. Temperature controller Chemical Thermo-con Cooling capacity 003 005 007 Combination in Set Part number of set Heat exchanger ∗ The tube size should be specified when ordering. Heat exchanger Temperature controller Temperature controller Heat exchanger
Open the catalog to page 5Chemical Thermo-con Main Specifications (For details, please consult our “Product Specifications” information.) Heat Exchanger Specifications Heat exchanger model Cooling capacity (Water) Note 1) Heating capacity (Water) Note 1) Peltier device (Thermoelectric device, Thermo-module) Radiating method Operating temperature range 50 to 140°F (10 to 60°C) (depending on the type of circulating fluid) Applicable fluid Note 2) Operating pressure Note 3) Deionized water, Hydrofluoric acid, Ammonia hydrogen peroxide solution, etc. Wetted parts material Tube size (PFA tube) Wetted parts material Max. operating...
Open the catalog to page 6The values shown on the performance chart are representative and not guaranteed. Allow a margin for safety to device when choosing the product. Cooling Capacity Circulating fluid: Clear water, Circulating fluid flow rate: 3.96 gpm (15 L/min), Facility water flow rate: 1.32 gpam (5 L/min) Circulating fluid temperature (°C) Circulating fluid temperature (°C) Circulating fluid temperature (°C) Heating Capacity Circulating fluid: Clear water, Circulating fluid flow rate: 3.96 gpm (15 L/min), Facility water flow rate: 1.32 (5 L/min) Circulating fluid temperature (°C) Circulating fluid temperature...
Open the catalog to page 7Chemical Thermo-con Pressure Loss in Circulating Fluid Circuit Clear water Clear water Pressure Loss in Facility Water Circuit Flow rate (L/min) Flow rate (L/min) Pressure loss Flow rate (L/min) Flow rate (L/min) Technical Data Related Products Pressure loss
Open the catalog to page 8Communication connector ∗ The RS-232C uses only lower side connector. Facility water outlet 3/8" x 1/4" Power switch Facility water inlet 3/8" x 1/4" Circulating fluid inlet Model no. label (Heat exchanger) 10.3 (263) Model no. label (Controller) (0.8 (20)) Signal connector Fluid leak sensor Terminal block Alarm output connector (1.2 )30)) Heat exchanger Wire color Circulating fluid tube size Connector: IEC 60320 C13 or equivalent Cable: 14AWG, O.D. ø8.4 Heat exchanger model Power Cable (Accessory) Circulating Fluid Tube Size 4.3 (110) Signal cable 16 ft (5 m) Circulating fluid 0.8 (20) outlet...
Open the catalog to page 9Chemical Thermo-con Fluid leak sensor REMOTE ON/OFF EXT.SENSOR + - FG A B B FG Signal connector Model no. label (Controller) Terminal block Power connector Facility water inlet 3/8" x 1/4" Circulating fluid inlet Model no. label (Heat exchanger) Facility water outlet 3/8" x 1/4" Power switch Display panel Alarm output connector Circulating fluid outlet Communication connector ∗ The RS-232C uses only upper side connector. Temperature controller Heat exchanger Connector: DDK CE05-6A18-10SD-D-BSS Cable: 12AWG, O.D. ø11.8 Contents Technical Data Wire color Power Cable (Accessory) Related Products...
Open the catalog to page 10Use the special power cable included with the temperature controller. Connect the DC cable and signal cable that come from the heat exchanger to the DC and signal connectors of the temperature controller. b Prepare other required connectors and wiring by the customer. b 1. Power connector IEC 60320 C14 or equivalent 4. Terminal block Morimatsu Co., Ltd.: M111A-7A, for holding screw M3 Connection cable: 22AWG or more, max. 32.8 feet (10 m) Connect the included special power cable. Pin No. Signal contents Signal contents Remote ON/OFF – Power connector External sensor: Terminal B of resistance...
Open the catalog to page 1167 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages