Product catalog summary
Overview: The document provides technical data and specifications for Thermo-con products, which are devices used to precisely control the temperature of circulating fluids in various applications. These devices utilize Peltier technology for heating and cooling, offering both air-cooled and water-cooled options.
Specifications: Thermo-con devices operate within a temperature range of 10°C to 60°C with a stability of ±0.01 to 0.03°C. They are available in different models with cooling capacities ranging from 140W to 1200W. The devices comply with safety standards for medical equipment and are suitable for use with various fluids, including water and fluorinated fluids.
Principles of Operation: The Peltier device, or thermo-module, is central to the Thermo-con's operation. It consists of alternating P-type and N-type semiconductors that transfer heat when a direct current is applied, allowing for rapid switching between heating and cooling. This precise control is achieved by adjusting the direction of the current.
Applications: Thermo-con devices are used in a variety of applications, including blood preservation, laser machining, and temperature control in electronic microscopes. They are suitable for environments with or without facility water equipment, depending on whether an air-cooled or water-cooled model is used.
Model Selection: Guidance is provided on selecting the appropriate model based on factors such as the presence of facility water equipment, the need to minimize ambient temperature effects, and the required cooling capacity. Considerations for the circulating fluid's flow rate and pressure loss are also included.
Performance Charts: Performance charts illustrate the cooling and heating capacities of the Thermo-con devices at various circulating fluid temperatures and flow rates, guiding users in selecting the appropriate model for their specific needs.
Additional Features: Thermo-con devices offer features such as learning control functions, compatibility with external temperature sensors, communication interfaces, and safety alarms.
Components: Key components include power and communication connectors, an alarm connector, an external temperature sensor connector, a display/operation panel, and a circulating fluid level gauge. The unit also features a tank lid with a gasket, circulating fluid inlet and outlet, and a drain port.
Alarms and Maintenance: The unit is equipped with 15 types of alarms displayed on the LCD and communicated via serial connections. Maintenance is primarily conducted at the manufacturer's site, with specific parts having a limited lifespan.
Safety and Handling: Emphasizes the importance of keeping the air filter clean to prevent performance degradation. Warns against removing panels due to hazardous voltage and advises against user servicing. Proper spacing for air intake and discharge is crucial to maintain operational efficiency.
Operating Environment: The chiller should be used within specified temperature and humidity ranges to avoid condensation and potential damage. It is not suitable for clean room environments due to dust generation from internal components.
Recommendations: Users are advised to read the operation manual thoroughly, maintain specified ambient conditions, and ensure proper arrangement of multiple units to prevent performance issues. Regular cleaning of filters and adherence to maintenance schedules are recommended to ensure optimal performance.
Installation Conditions: To maintain product performance and longevity, ensure ambient temperature does not exceed 95°F (35°C). Vent or exhaust air if necessary. Avoid dew condensation by supplying facility water above the atmospheric dew point. Limit Thermo-cons to two per facility water system to prevent excessive heat exchange.
Circulating Fluid Standards: Use clear water meeting specified quality standards to prevent corrosion and scale. Regularly exchange deionized water to avoid bacterial growth. Ensure circulating fluid pressure does not exceed 14.5 psi (0.1 MPa) and maintain a flow rate of at least 0.8 gpm (3 L/min). Avoid using fluids with metal powders and ensure the Thermo-con is not operated without circulating fluid.
System Precautions: Minimize piping resistance to prevent negative pressure and potential damage. Ground pipes when using fluorinated fluid to prevent static electricity damage. Avoid cavitation or bubbles to extend pump life.
Maintenance and Safety: Regular inspections should be conducted monthly by knowledgeable operators. Check for errors, abnormal sounds, and fluid quality. Ensure electrical safety by avoiding operation with wet hands and immediately addressing any errors such as smoke or unusual smells.
See more

Catalog excerpts

HEC series-1

Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Precisely control the temperature of the circulating fluid by using the Peltier device. Generates little vibration, and is refrigerant-free and environmentally friendly. Can control the temperature of the heat source by using the external temperature sensor (sold separately). (Automatically adjusts to the effects of ambient temperature.) Water-cooled Air-cooled Series HEC-A Air-cooled: Can be used in the environments with no cooling equipment. Circulating fluid Thermo-con Circulating fluid controlled to a constant temperature Water Heat source Cooling capacity: X-ray diagnostic instrument Fan Blood preservation equipment Electron microscope Peltier device (Thermo-module) Exchanges heat with the circulating fluid to maintain a constant temperature. Cools or heats the circulating fluid Series HEC-W Water-cooled: Can be used in the environments with facility water equipment. Circulating fluid Water, Fluorinated fluid 20% ethylene glycol Facility water Heat source RoHS Temperature control of chamber electrode Electron microscope Laser machining Cooling tower Temperature stability: Technical Data Added cooling capacity of 140 W and 320 W (watercooled), and 600 W (air-cooled). Temperature range setting: Related Products Can precisely control the temperature of a heat source or process fluid.

 Open the catalog to page 1
HEC series-2

b Compliant with safety standard for medical equipment IEC 60601-1 (Air-cooled/HEC002-A series) b Power supply: Applicable to 100 V to 240 V (Air-cooled/HEC-A series, Water-cooled/HEC001-W, HEC003-W) b Suitable to fluorinated fluids (FluorinertTM FC-3283, GALDEN® HT135) (Water-cooled/HEC006-W, HEC012-W) b Compatible with ethylene glycol 20% (Water-cooled/HEC001-W, Learning Control Function (Temp. control by external temperature sensor) This function adjusts the fluid temperature to the set value with an automatic offset setting. Set the external temperature sensor at the circulating fluid inlet...

 Open the catalog to page 2
HEC series-3

Construction and Principles Series HEC-A Noise filter Power switch Controller Power supply & Controller (Circulating fluid side) Peltier device (Thermo-module) Heat exchanger (Cooling side) Circulating fluid OUT Circulating fluid IN Circulating fluid supply port (Tank lid) Heat exchanger Switching power supply Circulating fluid drain port Flow switch (option) Level switch Tank Water-cooled Series HEC-W Figure 1 Power switch Controller Peltier device (Thermo-module) Heat exchanger (Cooling side) Supply tank *1 Optional setting for the HEC001 and 003 Facility water *2 Not built in the HEC001 and...

 Open the catalog to page 3
HEC series-4

When to Use Air-Cooled and Water-Cooled Thermo-con Both air-cooled and water-cooled Thermo-cons are available. Select a proper Thermo-con by referring to the following. Air-cooled • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. Water-cooled • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to reduce the installation space. Can reduce the space since the unit...

 Open the catalog to page 4
HEC series-5

• Model Selection Series HEC-A • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet) • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet)/ Pressure Loss in Facility Water Circuit • Specific Product Precautions Series HEC-W

 Open the catalog to page 5
HEC series-6

Model Selection Guide to Model Selection 1. What radiation method will be used? Without a cooling tower ··············Air-cooled HEC-A series With a cooling tower ··············Water-cooled HEC-W series When to Use Air-cooled and Water-cooled Thermo-con • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to reduce...

 Open the catalog to page 6
HEC series-7

Model Selection Guide to Model Selection Example 2 When the heat generation amount in the customer’s machine is not known. Heat generation amount Q : Unknown Circulating fluid temperature difference ∆T (= T2 – T1) : 0.8°C (0.8 K) Circulating fluid outlet temperature T1 : 25°C (298.15 K) Circulating fluid return temperature T2 : 25.8°C (298.95 K) Circulating fluid flow rate L : 3 L/min Circulating fluid : Water Density γ: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kg•K) γ T2: Return temperature Customer’s machine Obtain the temperature difference between inlet and outlet by circulating the fluid...

 Open the catalog to page 7
HEC series-8

Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A With flow switch NPT thread ∗ The option should be specified when ordering. ∗ Select B when communication is not used. Specifications (For details, please consult our “Product Specifications” information.) HEC002-A5A Cooling/Heating automatic shift PID control Control method Ambient temperature/humidity Clear water Circulating fluid Operating temperature range Circulating fluid system Radiating method Cooling capacity Heating capacity Temperature stability Note 3) ±0.018 to ±0.054°F (±0.01 to ±0.03°C) Refer to performance chart. Pump capacity...

 Open the catalog to page 8
HEC series-9

Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A Cooling Capacity The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. Circulating fluid: Clear water

 Open the catalog to page 9
HEC series-10

Parts Description HEC002 Power connector Display/Operation panel Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge Circulating fluid inlet Drain (circulating fluid drain port) HEC006 Display/Operation panel Power connector Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge Circulating...

 Open the catalog to page 10

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEB series

    9  Pages

  38. HRG series

    85  Pages

  39. HRZ series

    52  Pages

  40. HRW series

    28  Pages

  41. LQ series

    35  Pages

  42. PA series

    37  Pages

  43. LER series

    62  Pages

  44. LEJ series

    58  Pages

  45. LAT3 series

    24  Pages

  46. LEH series

    103  Pages

  47. CQS series

    59  Pages

  48. CH series

    175  Pages

  49. ARX series

    12  Pages

  50. HRS series

    47  Pages

  51. LES

    59  Pages

  52. MHS

    74  Pages

  53. MHY

    27  Pages

  54. MHC

    27  Pages

  55. MHR

    30  Pages

  56. MHZ series

    78  Pages

  57. MSQ

    37  Pages

  58. MGP

    127  Pages

  59. MXS

    38  Pages

  60. NRB

    10  Pages

  61. MXW

    22  Pages

  62. MHT

    11  Pages

  63. MY3

    54  Pages

  64. CQM

    15  Pages

  65. NCA1

    63  Pages

  66. CM2

    152  Pages

  67. NCM

    91  Pages

  68. NCG

    96  Pages

  69. NCRA1

    5  Pages

  70. CS2

    32  Pages

  71. T/TIA

    1  Page

  72. KR

    7  Pages

  73. KF

    16  Pages

  74. KQ

    80  Pages

  75. AFF

    80  Pages

  76. AMG

    80  Pages

  77. IDF

    16  Pages

  78. HAA

    3  Pages

  79. ZFA

    14  Pages

  80. ZA

    13  Pages

  81. MHF

    32  Pages

  82. CRB

    44  Pages

  83. D

    117  Pages

  84. RB

    23  Pages

  85. CEP

    44  Pages

  86. rsq

    30  Pages

  87. CLK

    51  Pages

  88. MK

    20  Pages

  89. CLJ

    65  Pages

  90. MGJ

    7  Pages

  91. ZSE30A

    17  Pages

  92. IDFB*E

    89  Pages

  93. ISE10

    16  Pages

  94. ITV1000/2000

    50  Pages

  95. AW

    27  Pages

  96. NVFM200

    12  Pages

  97. NVM100

    32  Pages

  98. LLA*A

    36  Pages

  99. VX3*

    41  Pages

  100. SY3000

    158  Pages

  101. CH(D)2

    175  Pages

  102. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.