Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Precisely control the temperature of the circulating fluid by using the Peltier device. Generates little vibration, and is refrigerant-free and environmentally friendly. Can control the temperature of the heat source by using the external temperature sensor (sold separately). (Automatically adjusts to the effects of ambient temperature.) Water-cooled Air-cooled Series HEC-A Air-cooled: Can be used in the environments with no cooling equipment. Circulating fluid Thermo-con Circulating fluid controlled to a constant temperature Water Heat source Cooling capacity: X-ray diagnostic instrument Fan Blood preservation equipment Electron microscope Peltier device (Thermo-module) Exchanges heat with the circulating fluid to maintain a constant temperature. Cools or heats the circulating fluid Series HEC-W Water-cooled: Can be used in the environments with facility water equipment. Circulating fluid Water, Fluorinated fluid 20% ethylene glycol Facility water Heat source RoHS Temperature control of chamber electrode Electron microscope Laser machining Cooling tower Temperature stability: Technical Data Added cooling capacity of 140 W and 320 W (watercooled), and 600 W (air-cooled). Temperature range setting: Related Products Can precisely control the temperature of a heat source or process fluid.
Open the catalog to page 1b Compliant with safety standard for medical equipment IEC 60601-1 (Air-cooled/HEC002-A series) b Power supply: Applicable to 100 V to 240 V (Air-cooled/HEC-A series, Water-cooled/HEC001-W, HEC003-W) b Suitable to fluorinated fluids (FluorinertTM FC-3283, GALDEN® HT135) (Water-cooled/HEC006-W, HEC012-W) b Compatible with ethylene glycol 20% (Water-cooled/HEC001-W, Learning Control Function (Temp. control by external temperature sensor) This function adjusts the fluid temperature to the set value with an automatic offset setting. Set the external temperature sensor at the circulating fluid inlet...
Open the catalog to page 2Construction and Principles Series HEC-A Noise filter Power switch Controller Power supply & Controller (Circulating fluid side) Peltier device (Thermo-module) Heat exchanger (Cooling side) Circulating fluid OUT Circulating fluid IN Circulating fluid supply port (Tank lid) Heat exchanger Switching power supply Circulating fluid drain port Flow switch (option) Level switch Tank Water-cooled Series HEC-W Figure 1 Power switch Controller Peltier device (Thermo-module) Heat exchanger (Cooling side) Supply tank *1 Optional setting for the HEC001 and 003 Facility water *2 Not built in the HEC001 and...
Open the catalog to page 3When to Use Air-Cooled and Water-Cooled Thermo-con Both air-cooled and water-cooled Thermo-cons are available. Select a proper Thermo-con by referring to the following. Air-cooled • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. Water-cooled • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to reduce the installation space. Can reduce the space since the unit...
Open the catalog to page 4• Model Selection Series HEC-A • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet) • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet)/ Pressure Loss in Facility Water Circuit • Specific Product Precautions Series HEC-W
Open the catalog to page 5Model Selection Guide to Model Selection 1. What radiation method will be used? Without a cooling tower ··············Air-cooled HEC-A series With a cooling tower ··············Water-cooled HEC-W series When to Use Air-cooled and Water-cooled Thermo-con • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to reduce...
Open the catalog to page 6Model Selection Guide to Model Selection Example 2 When the heat generation amount in the customer’s machine is not known. Heat generation amount Q : Unknown Circulating fluid temperature difference ∆T (= T2 – T1) : 0.8°C (0.8 K) Circulating fluid outlet temperature T1 : 25°C (298.15 K) Circulating fluid return temperature T2 : 25.8°C (298.95 K) Circulating fluid flow rate L : 3 L/min Circulating fluid : Water Density γ: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kg•K) γ T2: Return temperature Customer’s machine Obtain the temperature difference between inlet and outlet by circulating the fluid...
Open the catalog to page 7Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A With flow switch NPT thread ∗ The option should be specified when ordering. ∗ Select B when communication is not used. Specifications (For details, please consult our “Product Specifications” information.) HEC002-A5A Cooling/Heating automatic shift PID control Control method Ambient temperature/humidity Clear water Circulating fluid Operating temperature range Circulating fluid system Radiating method Cooling capacity Heating capacity Temperature stability Note 3) ±0.018 to ±0.054°F (±0.01 to ±0.03°C) Refer to performance chart. Pump capacity...
Open the catalog to page 8Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A Cooling Capacity The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. Circulating fluid: Clear water
Open the catalog to page 9Parts Description HEC002 Power connector Display/Operation panel Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge Circulating fluid inlet Drain (circulating fluid drain port) HEC006 Display/Operation panel Power connector Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge Circulating...
Open the catalog to page 1067 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages