Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Precisely control the temperature of the circulating fluid by using the Peltier device. Generates little vibration, and is refrigerant-free and environmentally friendly. Can control the temperature of the heat source by using the external temperature sensor (sold separately). (Automatically adjusts to the effects of ambient temperature.) Water-cooled Air-cooled Series HEC-A Air-cooled: Can be used in the environments with no cooling equipment. Circulating fluid Thermo-con Circulating fluid controlled to a constant temperature Water Heat source Cooling capacity: X-ray diagnostic instrument Fan Blood preservation equipment Electron microscope Peltier device (Thermo-module) Exchanges heat with the circulating fluid to maintain a constant temperature. Cools or heats the circulating fluid Series HEC-W Water-cooled: Can be used in the environments with facility water equipment. Circulating fluid Water, Fluorinated fluid 20% ethylene glycol Facility water Heat source RoHS Temperature control of chamber electrode Electron microscope Laser machining Cooling tower Temperature stability: Technical Data Added cooling capacity of 140 W and 320 W (watercooled), and 600 W (air-cooled). Temperature range setting: Related Products Can precisely control the temperature of a heat source or process fluid.
Open the catalog to page 1b Compliant with safety standard for medical equipment IEC 60601-1 (Air-cooled/HEC002-A series) b Power supply: Applicable to 100 V to 240 V (Air-cooled/HEC-A series, Water-cooled/HEC001-W, HEC003-W) b Suitable to fluorinated fluids (FluorinertTM FC-3283, GALDEN® HT135) (Water-cooled/HEC006-W, HEC012-W) b Compatible with ethylene glycol 20% (Water-cooled/HEC001-W, Learning Control Function (Temp. control by external temperature sensor) This function adjusts the fluid temperature to the set value with an automatic offset setting. Set the external temperature sensor at the circulating fluid...
Open the catalog to page 2Construction and Principles Series HEC-A Noise filter Power switch Controller Power supply & Controller (Circulating fluid side) Peltier device (Thermo-module) Heat exchanger (Cooling side) Circulating fluid OUT Circulating fluid IN Circulating fluid supply port (Tank lid) Heat exchanger Switching power supply Circulating fluid drain port Flow switch (option) Level switch Tank Water-cooled Series HEC-W Figure 1 Power switch Controller Peltier device (Thermo-module) Heat exchanger (Cooling side) Supply tank *1 Optional setting for the HEC001 and 003 Facility water *2 Not built in the HEC001...
Open the catalog to page 3When to Use Air-Cooled and Water-Cooled Thermo-con Both air-cooled and water-cooled Thermo-cons are available. Select a proper Thermo-con by referring to the following. Air-cooled • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. Water-cooled • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to reduce the installation space. Can reduce the space since the...
Open the catalog to page 4• Model Selection Series HEC-A • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet) • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet)/ Pressure Loss in Facility Water Circuit • Specific Product Precautions Series HEC-W
Open the catalog to page 5Model Selection Guide to Model Selection 1. What radiation method will be used? Without a cooling tower ··············Air-cooled HEC-A series With a cooling tower ··············Water-cooled HEC-W series When to Use Air-cooled and Water-cooled Thermo-con • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to...
Open the catalog to page 6Model Selection Guide to Model Selection Example 2 When the heat generation amount in the customer’s machine is not known. Heat generation amount Q : Unknown Circulating fluid temperature difference ∆T (= T2 – T1) : 0.8°C (0.8 K) Circulating fluid outlet temperature T1 : 25°C (298.15 K) Circulating fluid return temperature T2 : 25.8°C (298.95 K) Circulating fluid flow rate L : 3 L/min Circulating fluid : Water Density γ: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kg•K) γ T2: Return temperature Customer’s machine Obtain the temperature difference between inlet and outlet by circulating the...
Open the catalog to page 7Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A With flow switch NPT thread ∗ The option should be specified when ordering. ∗ Select B when communication is not used. Specifications (For details, please consult our “Product Specifications” information.) HEC002-A5A Cooling/Heating automatic shift PID control Control method Ambient temperature/humidity Clear water Circulating fluid Operating temperature range Circulating fluid system Radiating method Cooling capacity Heating capacity Temperature stability Note 3) ±0.018 to ±0.054°F (±0.01 to ±0.03°C) Refer to performance chart. Pump...
Open the catalog to page 8Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A Cooling Capacity The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. Circulating fluid: Clear water
Open the catalog to page 9Parts Description HEC002 Power connector Display/Operation panel Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge Circulating fluid inlet Drain (circulating fluid drain port) HEC006 Display/Operation panel Power connector Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge...
Open the catalog to page 10All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages