HEC series
32Pages

{{requestButtons}}

Catalog excerpts

HEC series - 1

Peltier-Type Chiller Thermo-con Air-cooled Water-cooled Precisely control the temperature of the circulating fluid by using the Peltier device. Generates little vibration, and is refrigerant-free and environmentally friendly. Can control the temperature of the heat source by using the external temperature sensor (sold separately). (Automatically adjusts to the effects of ambient temperature.) Water-cooled Air-cooled Series HEC-A Air-cooled: Can be used in the environments with no cooling equipment. Circulating fluid Thermo-con Circulating fluid controlled to a constant temperature Water Heat source Cooling capacity: X-ray diagnostic instrument Fan Blood preservation equipment Electron microscope Peltier device (Thermo-module) Exchanges heat with the circulating fluid to maintain a constant temperature. Cools or heats the circulating fluid Series HEC-W Water-cooled: Can be used in the environments with facility water equipment. Circulating fluid Water, Fluorinated fluid 20% ethylene glycol Facility water Heat source RoHS Temperature control of chamber electrode Electron microscope Laser machining Cooling tower Temperature stability: Technical Data Added cooling capacity of 140 W and 320 W (watercooled), and 600 W (air-cooled). Temperature range setting: Related Products Can precisely control the temperature of a heat source or process fluid.

Open the catalog to page 1
HEC series - 2

b Compliant with safety standard for medical equipment IEC 60601-1 (Air-cooled/HEC002-A series) b Power supply: Applicable to 100 V to 240 V (Air-cooled/HEC-A series, Water-cooled/HEC001-W, HEC003-W) b Suitable to fluorinated fluids (FluorinertTM FC-3283, GALDEN® HT135) (Water-cooled/HEC006-W, HEC012-W) b Compatible with ethylene glycol 20% (Water-cooled/HEC001-W, Learning Control Function (Temp. control by external temperature sensor) This function adjusts the fluid temperature to the set value with an automatic offset setting. Set the external temperature sensor at the circulating fluid...

Open the catalog to page 2
HEC series - 3

Construction and Principles Series HEC-A Noise filter Power switch Controller Power supply & Controller (Circulating fluid side) Peltier device (Thermo-module) Heat exchanger (Cooling side) Circulating fluid OUT Circulating fluid IN Circulating fluid supply port (Tank lid) Heat exchanger Switching power supply Circulating fluid drain port Flow switch (option) Level switch Tank Water-cooled Series HEC-W Figure 1 Power switch Controller Peltier device (Thermo-module) Heat exchanger (Cooling side) Supply tank *1 Optional setting for the HEC001 and 003 Facility water *2 Not built in the HEC001...

Open the catalog to page 3
HEC series - 4

When to Use Air-Cooled and Water-Cooled Thermo-con Both air-cooled and water-cooled Thermo-cons are available. Select a proper Thermo-con by referring to the following. Air-cooled • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. Water-cooled • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to reduce the installation space. Can reduce the space since the...

Open the catalog to page 4
HEC series - 5

• Model Selection Series HEC-A • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet) • Cooling Capacity/Heating Capacity/ Pump Capacity (Thermo-con Outlet)/ Pressure Loss in Facility Water Circuit • Specific Product Precautions Series HEC-W

Open the catalog to page 5
HEC series - 6

Model Selection Guide to Model Selection 1. What radiation method will be used? Without a cooling tower ··············Air-cooled HEC-A series With a cooling tower ··············Water-cooled HEC-W series When to Use Air-cooled and Water-cooled Thermo-con • No facility water equipment Can install the unit easily without facility water equipment. • Frequent piping changes Can reduce the piping installation labor since facility water piping is not required. • Need to avoid effects of ambient temperature. Since the unit is water-cooled, the ambient temperature will have little effect. • Want to...

Open the catalog to page 6
HEC series - 7

Model Selection Guide to Model Selection Example 2 When the heat generation amount in the customer’s machine is not known. Heat generation amount Q : Unknown Circulating fluid temperature difference ∆T (= T2 – T1) : 0.8°C (0.8 K) Circulating fluid outlet temperature T1 : 25°C (298.15 K) Circulating fluid return temperature T2 : 25.8°C (298.95 K) Circulating fluid flow rate L : 3 L/min Circulating fluid : Water Density γ: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kg•K) γ T2: Return temperature Customer’s machine Obtain the temperature difference between inlet and outlet by circulating the...

Open the catalog to page 7
HEC series - 8

Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A With flow switch NPT thread ∗ The option should be specified when ordering. ∗ Select B when communication is not used. Specifications (For details, please consult our “Product Specifications” information.) HEC002-A5A Cooling/Heating automatic shift PID control Control method Ambient temperature/humidity Clear water Circulating fluid Operating temperature range Circulating fluid system Radiating method Cooling capacity Heating capacity Temperature stability Note 3) ±0.018 to ±0.054°F (±0.01 to ±0.03°C) Refer to performance chart. Pump...

Open the catalog to page 8
HEC series - 9

Peltier-Type Chiller Thermo-con (Air-cooled) Series HEC-A Cooling Capacity The values shown on the performance chart are not guaranteed, but typical. Allow margins for safety when selecting the model. Circulating fluid: Clear water

Open the catalog to page 9
HEC series - 10

Parts Description HEC002 Power connector Display/Operation panel Handle Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Handle Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge Circulating fluid inlet Drain (circulating fluid drain port) HEC006 Display/Operation panel Power connector Communication connector RS-232C type 1 pc. RS-485 type 2 pcs. Power switch Tank lid with gasket Alarm connector External temperature sensor connector Circulating fluid outlet Circulating fluid level gauge...

Open the catalog to page 10

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEB series

    9 Pages

  34. HRG series

    85 Pages

  35. HRZ series

    52 Pages

  36. HRW series

    28 Pages

  37. LQ series

    35 Pages

  38. PA series

    37 Pages

  39. LER series

    62 Pages

  40. LEJ series

    58 Pages

  41. LAT3 series

    24 Pages

  42. LEH series

    103 Pages

  43. CQS series

    59 Pages

  44. CH series

    175 Pages

  45. ARX series

    12 Pages

  46. HRS series

    47 Pages

  47. LES

    59 Pages

  48. MHS

    74 Pages

  49. MHY

    27 Pages

  50. MHC

    27 Pages

  51. MHR

    30 Pages

  52. MHZ series

    78 Pages

  53. MSQ

    37 Pages

  54. MGP

    127 Pages

  55. MXS

    38 Pages

  56. NRB

    10 Pages

  57. MXW

    22 Pages

  58. MHT

    11 Pages

  59. MY3

    54 Pages

  60. CQM

    15 Pages

  61. NCA1

    63 Pages

  62. CM2

    152 Pages

  63. NCM

    91 Pages

  64. NCG

    96 Pages

  65. NCRA1

    5 Pages

  66. CS2

    32 Pages

  67. T/TIA

    1 Pages

  68. KR

    7 Pages

  69. KF

    16 Pages

  70. KQ

    80 Pages

  71. AFF

    80 Pages

  72. AMG

    80 Pages

  73. IDF

    16 Pages

  74. HAA

    3 Pages

  75. ZFA

    14 Pages

  76. ZA

    13 Pages

  77. MHF

    32 Pages

  78. CRB

    44 Pages

  79. D

    117 Pages

  80. RB

    23 Pages

  81. CEP

    44 Pages

  82. rsq

    30 Pages

  83. CLK

    51 Pages

  84. MK

    20 Pages

  85. CLJ

    65 Pages

  86. MGJ

    7 Pages

  87. ZSE30A

    17 Pages

  88. IDFB*E

    89 Pages

  89. ISE10

    16 Pages

  90. ITV1000/2000

    50 Pages

  91. AW

    27 Pages

  92. NVFM200

    12 Pages

  93. NVM100

    32 Pages

  94. LLA*A

    36 Pages

  95. VX3*

    41 Pages

  96. SY3000

    158 Pages

  97. CH(D)2

    175 Pages

  98. LEHZ

    82 Pages

  99. M(D)SUB

    31 Pages

  100. CXSJ

    58 Pages

  101. CY3B

    39 Pages

  102. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages