EX600, Analog Input/Output Unit - 1

Fieldbus System Applicable Fieldbus protocols Reduction in wiring time with SPEEDCON (Phoenix Contact). Just insert and make 1/2 rotation! New unit type added SI Unit (PROFINET) IP67 Note) Some products are IP40. Handheld Terminal Self diagnosis function It is possible to ascertain the maintenance period and identify the parts that require maintenance, by an input/output open circuit detection function and an input/output signal ON/OFF counter function. Also, the monitoring of input and output signals and the setting of parameters can be performed with a Handheld Terminal. Max. units Note) Can be connected in any order. The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order. Note) Except SI Unit Manifold Solenoid Valves Series SY3000/5000

Open the catalog to page 1
EX600, Analog Input/Output Unit - 2

Fieldbus System Analog Unit Input device M12 connector (5 pins) Input Unit PROFINET added to compatible communication networks Output Unit Pressure sensor Input/ Output Unit Output device Handheld Terminal Parameter setting and I/O monitor tool IP67 Units can be differentiated by color. Input Unit Input Unit Output Unit Input/Output Unit Input Unit Input/Output Unit Power supply Digital Unit Analog Unit For detailed specifications of connectable device, refer to the catalog of each device and select the right device for your application. If anything is unclear, contact us. Digital Unit M12...

Open the catalog to page 2
EX600, Analog Input/Output Unit - 3

Parameters A parameter is a set value to change the function and operation of the product through a PLC or Handheld Terminal. The desired operation for the customer’s application is realized by the set values. There are some parameters that can only be set using the Handheld Terminal of this series. Unit to connect various Fieldbus with the EX600 system • How to Order • Specifications • Parts Description • Dimensions Digital Unit Unit to input or output digital (switch) signals • How to Order • Specifications • Parts Description • Dimensions Manifold solenoid valves Analog Unit Unit to...

Open the catalog to page 3
EX600, Analog Input/Output Unit - 4

Fieldbus System Connection using D-sub connector Cable with D-sub connector These units are capable of connection using a D-sub connector. There are three types of units, for digital input, output, and input/output. The Digital Output Unit can be connected with an SMC manifold solenoid valve F kit (D-sub connector). Manifold solenoid valve can be connected using cable with D-sub connector. • Series SY • Series S0700 • Series SJ • Series SQ • Series SV • Series VQC • Series VQ ∗ Please limit the number of valve connections to 16 stations for single and 8 stations for double. Refer to the...

Open the catalog to page 4
EX600, Analog Input/Output Unit - 5

Series EX600 Individual units can be connected and removed one by one. A unique clamping method is adopted to prevent screws from falling out. It is easy to separate the unit just by loosening bracket screws. It is also possible to add and remove stations of solenoid valves on the manifold one by one, but the method is different. Handheld Terminal Forced input and output function The input and output signals are controlled forcedly without a PLC. The startup time after facility introduction can be shortened. Password setting function Can be used for the adjustment of internal parameters and...

Open the catalog to page 5
EX600, Analog Input/Output Unit - 6

Fieldbus System Protocol Description PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™ Note 1) EtherCAT Note 1) PROFINET Note 1) Description When MJ or EN or EC or PN is selected When PR or DN is selected Output type Symbol Digital Input Unit Description PNP (Negative common) NPN (Positive common) EX600 DX Input type Symbol Digital Output Unit Number of Open circuit Connector inputs detection M12 connector (5 pins) 4 pcs. 8 inputs No M8 connector (3 pins) 8 pcs. 8 inputs No M8 connector (3 pins) 8 pcs. 8 inputs Yes M12 connector (5 pins) 8 pcs. 16 inputs No D-sub connector (25 pins) Note1) 2) 16...

Open the catalog to page 6
EX600, Analog Input/Output Unit - 7

Fieldbus System Analog Input Unit Number of input channels and connector Symbol Analog Output Unit Connector M12 connector (5 pins) 2 pcs. Number of output channels and connector Symbol Analog Input/Output Unit Number of input channels 2 channels Number of output channels 2 channels Number of input/output channels and connector Symbol Number of output channels Number of input channels 2 channels EX600 ED Power connector Symbol Handheld Terminal Connector M12 (5 pins) 7/8 inch (5 pins) Mounting method Symbol Nil Description Without DIN rail mounting bracket With DIN rail mounting bracket...

Open the catalog to page 7
EX600, Analog Input/Output Unit - 8

Series EX600 SI Unit Specifications All Units Common Specifications Environmental resistance Operating temperature range Storage temperature range Operating humidity range Withstand voltage Note) Insulation resistance Note) Note) Except Handheld Terminals 14 to 122°F (–10 to 50°C) – 4 to 140°F (–20 to 60°C) 35 to 85% RH (No dew condensation) 500 VAC for 1 minute between external terminals and FE 500 VDC, 10 MΩ or more between external terminals and FE Communication speed Configuration file Occupation area (Number of inputs/outputs) Terminating resistor Internal current consumption (Power...

Open the catalog to page 8
EX600, Analog Input/Output Unit - 9

Fieldbus System SI Unit (EX600-SEN) Model Protocol Media Communication speed Communication method Configuration file Occupation area (Number of inputs/outputs) EtherNet/IP™ (Conformance version: Composite 6) 100 BASE-TX 10/100 Mbps (Automatic/Manual) Full duplex/Half duplex (Automatic/Manual) EDS file Max. (512 inputs/512 outputs) SI Unit switch settings: 192.168.0 or 1.1 to 254 Through DHCP server: Optional address Device information IP address setting range Vendor ID: 7 (SMC Corporation) Product type: 12 (Communication Adapter) Product code: 126 Internal current consumption (Power supply...

Open the catalog to page 9
EX600, Analog Input/Output Unit - 10

Series EX600 Digital Unit Specifications Digital Input Unit Model Input type Input connector Number of inputs Short-circuit protection 9 mA or less 17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V) 5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V) — 2 wires Open circuit detection current 3 wires Current consumption Protection Input current (at 24...

Open the catalog to page 10

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. HRS series

    47 Pages

  48. LES

    59 Pages

  49. MHS

    74 Pages

  50. MHY

    27 Pages

  51. MHC

    27 Pages

  52. MHR

    30 Pages

  53. MHZ series

    78 Pages

  54. MSQ

    37 Pages

  55. MGP

    127 Pages

  56. MXS

    38 Pages

  57. NRB

    10 Pages

  58. MXW

    22 Pages

  59. MHT

    11 Pages

  60. MY3

    54 Pages

  61. CQM

    15 Pages

  62. NCA1

    63 Pages

  63. CM2

    152 Pages

  64. NCM

    91 Pages

  65. NCG

    96 Pages

  66. NCRA1

    5 Pages

  67. CS2

    32 Pages

  68. T/TIA

    1 Pages

  69. KR

    7 Pages

  70. KF

    16 Pages

  71. KQ

    80 Pages

  72. AFF

    80 Pages

  73. AMG

    80 Pages

  74. IDF

    16 Pages

  75. HAA

    3 Pages

  76. ZFA

    14 Pages

  77. ZA

    13 Pages

  78. MHF

    32 Pages

  79. CRB

    44 Pages

  80. D

    117 Pages

  81. RB

    23 Pages

  82. CEP

    44 Pages

  83. rsq

    30 Pages

  84. CLK

    51 Pages

  85. MK

    20 Pages

  86. CLJ

    65 Pages

  87. MGJ

    7 Pages

  88. ZSE30A

    17 Pages

  89. IDFB*E

    89 Pages

  90. ISE10

    16 Pages

  91. ITV1000/2000

    50 Pages

  92. AW

    27 Pages

  93. NVFM200

    12 Pages

  94. NVM100

    32 Pages

  95. LLA*A

    36 Pages

  96. VX3*

    41 Pages

  97. SY3000

    158 Pages

  98. CH(D)2

    175 Pages

  99. LEHZ

    82 Pages

  100. M(D)SUB

    31 Pages

  101. CXSJ

    58 Pages

  102. CY3B

    39 Pages

  103. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages