Catalog excerpts
Fieldbus System Applicable Fieldbus protocols Reduction in wiring time with SPEEDCON (Phoenix Contact). Just insert and make 1/2 rotation! New unit type added SI Unit (PROFINET) IP67 Note) Some products are IP40. Handheld Terminal Self diagnosis function It is possible to ascertain the maintenance period and identify the parts that require maintenance, by an input/output open circuit detection function and an input/output signal ON/OFF counter function. Also, the monitoring of input and output signals and the setting of parameters can be performed with a Handheld Terminal. Max. units Note) Can be connected in any order. The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order. Note) Except SI Unit Manifold Solenoid Valves Series SY3000/5000
Open the catalog to page 1Fieldbus System Analog Unit Input device M12 connector (5 pins) Input Unit PROFINET added to compatible communication networks Output Unit Pressure sensor Input/ Output Unit Output device Handheld Terminal Parameter setting and I/O monitor tool IP67 Units can be differentiated by color. Input Unit Input Unit Output Unit Input/Output Unit Input Unit Input/Output Unit Power supply Digital Unit Analog Unit For detailed specifications of connectable device, refer to the catalog of each device and select the right device for your application. If anything is unclear, contact us. Digital Unit M12...
Open the catalog to page 2Parameters A parameter is a set value to change the function and operation of the product through a PLC or Handheld Terminal. The desired operation for the customer’s application is realized by the set values. There are some parameters that can only be set using the Handheld Terminal of this series. Unit to connect various Fieldbus with the EX600 system • How to Order • Specifications • Parts Description • Dimensions Digital Unit Unit to input or output digital (switch) signals • How to Order • Specifications • Parts Description • Dimensions Manifold solenoid valves Analog Unit Unit to...
Open the catalog to page 3Fieldbus System Connection using D-sub connector Cable with D-sub connector These units are capable of connection using a D-sub connector. There are three types of units, for digital input, output, and input/output. The Digital Output Unit can be connected with an SMC manifold solenoid valve F kit (D-sub connector). Manifold solenoid valve can be connected using cable with D-sub connector. • Series SY • Series S0700 • Series SJ • Series SQ • Series SV • Series VQC • Series VQ ∗ Please limit the number of valve connections to 16 stations for single and 8 stations for double. Refer to the...
Open the catalog to page 4Series EX600 Individual units can be connected and removed one by one. A unique clamping method is adopted to prevent screws from falling out. It is easy to separate the unit just by loosening bracket screws. It is also possible to add and remove stations of solenoid valves on the manifold one by one, but the method is different. Handheld Terminal Forced input and output function The input and output signals are controlled forcedly without a PLC. The startup time after facility introduction can be shortened. Password setting function Can be used for the adjustment of internal parameters and...
Open the catalog to page 5Fieldbus System Protocol Description PROFIBUS DP DeviceNet™ CC-Link EtherNet/IP™ Note 1) EtherCAT Note 1) PROFINET Note 1) Description When MJ or EN or EC or PN is selected When PR or DN is selected Output type Symbol Digital Input Unit Description PNP (Negative common) NPN (Positive common) EX600 DX Input type Symbol Digital Output Unit Number of Open circuit Connector inputs detection M12 connector (5 pins) 4 pcs. 8 inputs No M8 connector (3 pins) 8 pcs. 8 inputs No M8 connector (3 pins) 8 pcs. 8 inputs Yes M12 connector (5 pins) 8 pcs. 16 inputs No D-sub connector (25 pins) Note1) 2) 16...
Open the catalog to page 6Fieldbus System Analog Input Unit Number of input channels and connector Symbol Analog Output Unit Connector M12 connector (5 pins) 2 pcs. Number of output channels and connector Symbol Analog Input/Output Unit Number of input channels 2 channels Number of output channels 2 channels Number of input/output channels and connector Symbol Number of output channels Number of input channels 2 channels EX600 ED Power connector Symbol Handheld Terminal Connector M12 (5 pins) 7/8 inch (5 pins) Mounting method Symbol Nil Description Without DIN rail mounting bracket With DIN rail mounting bracket...
Open the catalog to page 7Series EX600 SI Unit Specifications All Units Common Specifications Environmental resistance Operating temperature range Storage temperature range Operating humidity range Withstand voltage Note) Insulation resistance Note) Note) Except Handheld Terminals 14 to 122°F (–10 to 50°C) – 4 to 140°F (–20 to 60°C) 35 to 85% RH (No dew condensation) 500 VAC for 1 minute between external terminals and FE 500 VDC, 10 MΩ or more between external terminals and FE Communication speed Configuration file Occupation area (Number of inputs/outputs) Terminating resistor Internal current consumption (Power...
Open the catalog to page 8Fieldbus System SI Unit (EX600-SEN) Model Protocol Media Communication speed Communication method Configuration file Occupation area (Number of inputs/outputs) EtherNet/IP™ (Conformance version: Composite 6) 100 BASE-TX 10/100 Mbps (Automatic/Manual) Full duplex/Half duplex (Automatic/Manual) EDS file Max. (512 inputs/512 outputs) SI Unit switch settings: 192.168.0 or 1.1 to 254 Through DHCP server: Optional address Device information IP address setting range Vendor ID: 7 (SMC Corporation) Product type: 12 (Communication Adapter) Product code: 126 Internal current consumption (Power supply...
Open the catalog to page 9Series EX600 Digital Unit Specifications Digital Input Unit Model Input type Input connector Number of inputs Short-circuit protection 9 mA or less 17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V) 5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V) — 2 wires Open circuit detection current 3 wires Current consumption Protection Input current (at 24...
Open the catalog to page 10All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages