Digital Flow Switch
24Pages

{{requestButtons}}

Catalog excerpts

Digital Flow Switch - 1

Digital Flow Switch Applicable fluid Expanded flow range! Flow ratio∗ Wide range of flow measurement with one product Setting resolution: 1 L/min ∗ Rated flow ratio is 10 : 1 for current PF2A. Current PF2A: 5 L/min (200 L: 2 L/min) Applicable flow range [L/min] Compact, Space saving Compared with the current PF2A, Weight Mounting space Compared with the current PF2A, Weight Mounting space (Current model) Series PFMB

Open the catalog to page 1
Digital Flow Switch - 2

Series PFMB 2-Color Display Digital Flow Switch Flow adjustment valve is integrated. 200 L type Flow adjustment valve Reduces piping installation work and space requirements. Special design provides smooth adjustment to match needle rotations. Response time Can be selected from Response time can be set depending on application. Piping variations Straight One-touch fitting ø8 Reverse display When the switch is used upside down, the orientation of the display can be rotated to make it easier to read. When display is upside down. Bottom Female thread Rc, NPT, G 1/4 With reverse display...

Open the catalog to page 2
Digital Flow Switch - 3

2-Color Display Digital Flow Switch Series PFMB Digital flow switch to save energy! Flow control is necessary for promoting energy saving in any application. Saving energy starts from numerical control of the flow consumption of equipment and lines and clarification of the purpose and effect. Main line flow control Flow control for each branch line Remote control is possible with accumulated pulse. Digital display allows visualization of flow rate. 2-color display, Improved visibility Refer to the WEB catalog or the Best Pneumatics No. 3 for details of multi-counter CEU5. Control of purge...

Open the catalog to page 3
Digital Flow Switch - 4

Flow Switch Flow Rate Variations Series Applicable Detection Minimum method setting unit fluid Applicable flow range [L/min] −3 Thermal type (MEMS) Applicable Detection Minimum fluid method setting unit Thermal type (MEMS) Thermal type (MEMS) Bypass flow type Thermal type (MEMS) Bypass flow type Thermal type (Thermistor) 2 L/min 5 L/min 5 L/min 1 L/min = 0.264 gal/min (1 gal/min = 3

Open the catalog to page 4
Digital Flow Switch - 5

Rated flow range 0 to 0.5 L/min −0.5 to 0.5 L/min 0 to 1 L/min −1 to 1 L/min 0 to 3 L/min −3 to 3 L/min 0.2 to 10 L/min 0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 1 to 10 L/min 50 to 500 L/min 5 to 50 L/min 150 to 3000 L/min 10 to 100 L/min 300 to 6000 L/min 20 to 200 L/min 600 to 12000 L/min Power supply voltage ±1% F.S. Monitor unit (Fluid: Dry air) ±0.1% F.S. Analog output: Analog output: ±0.5% F.S. ±5% F.S. ±1% F.S. (Fluid: Dry air) Analog output: ±3% F.S. Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode:...

Open the catalog to page 5
Digital Flow Switch - 6

Digital Flow Switch M Calibration certificate Note 1) Nil A∗ Rated flow range (Flow rate range) 201 Note 1) Certificate in both English and Japanese ∗ Made to Order Flow adjustment valve Nil S Unit specifications SI unit only Note 2) Unit selection function Note 3) Note 2) Fixed unit: Instantaneous flow: L/min Accumulated flow: L Note 3) Since the unit for Japan is fixed to SI due to new measurement law, this option is for overseas. Unit can be changed. Instantaneous flow: L/min⇔cfm Accumulated flow: L⇔ft3 None With calibration certificate Note 4) ISO1179-1 compliant ∗ Made to Order R With...

Open the catalog to page 6
Digital Flow Switch - 7

2-Color Dispaly Digital Flow Switch Rated flow range (Flow rate range) 501 102 202 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min Calibration certificate Note 1) Nil A∗ None With calibration certificate Note 1) Certificate in both English and Japanese ∗ Made to Order With bracket With 4 self-tapping screws OUT2 NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Analog 1 to 5 V Analog 4 to 20 mA External input Note 4) External input Note 4) Note) Each option is not assembled with the product, but shipped together. If an accessory is required, refer to “Option 2/Part No.” below. Note 4) Accumulated flow,...

Open the catalog to page 7
Digital Flow Switch - 8

For Flow Switch Precautions, refer to “Handling Precautions for SMC Products” on SMC website. For Specific Product Precautions, refer to the Operation Manual on SMC website. Model PFMB7202 PFMB7201 PFMB7501 PFMB7102 Applicable fluid Note 1) Dry air, N2 (Air quality grade is JIS B 8392-1 1.1.2 to 1.6.2, ISO 8573-1 1.1.2 to 1.6.2.) Fluid temperature range 32 to 122°F [0 to 50°C] Detection method Thermal type Rated flow range 2 to 200 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow 2 to 210 L/min 5 to 525 L/min 10 to 1050 L/min 20 to 2100 L/min Set flow rate range...

Open the catalog to page 8
Digital Flow Switch - 9

2-Color Display Digital Flow Switch Flow Range Model 2 L/min 2 L/min −10 L/min Flow range 500 L/min 5 L/min 5 L/min −25 L/min 500 L/min 525 L/min 525 L/min 200 L/min 210 L/min 210 L/min 1000 L/min 1050 L/min 1050 L/min −50 L/min 20 L/min 20 L/min 2000 L/min 2100 L/min 2100 L/min −100 L/min Rated flow range Analog Output Flow Adjustment Valve Flow-rate Characteristics Current output Voltage output Flow/Analog Output Minimum flow of Maximum flow of rated flow range rated flow range (Without flow adjustment valve) Minimum flow of rated flow range Maximum flow of rated flow range Supply pressure...

Open the catalog to page 9
Digital Flow Switch - 10

Series PFMB7 Construction/Fluid Contact Parts PFMB7201 !0 !1 !0 o i u q w e r t y u !3 o !0 !1 Description Sensor body Sensor chip Printed circuit board Flow rectifier Fluoro coating Electroless nickel plating Fluoro coating Flow rectifier Stainless steel 304 Fluoro coating Bottom piping adapter Flow adjustment valve body Electroless nickel plating Electroless nickel plating Fluoro coating Fluoro coating Fluoro coating Description Sensor body Flow rectifier Sensor chip Printed circuit board

Open the catalog to page 10
Digital Flow Switch - 11

2-Color Display Digital Flow Switch Internal Circuits and Wiring Examples NPN (2 outputs) type Max. applied voltage: 28V, Max. load current: 80mA, Internal voltage drop: 1V or less Max. load current: 80 mA, Internal voltage drop: 1.5 V or less PNP (1 output) + Analog (1 to 5 V) output type PFMB7 -E PNP (1 output) + Analog (4 to 20 mA) output type NPN (1 output) + Analog (1 to 5 V) output type -C PFMB7 NPN (1 output) + Analog (4 to 20 mA) output type White Analog output White Analog output Main circuit Main circuit Main circuit Main circuit Max. applied voltage: 28 V, Max. load current: 80...

Open the catalog to page 11

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. HRS series

    47 Pages

  48. LES

    59 Pages

  49. MHS

    74 Pages

  50. MHY

    27 Pages

  51. MHC

    27 Pages

  52. MHR

    30 Pages

  53. MHZ series

    78 Pages

  54. MSQ

    37 Pages

  55. MGP

    127 Pages

  56. MXS

    38 Pages

  57. NRB

    10 Pages

  58. MXW

    22 Pages

  59. MHT

    11 Pages

  60. MY3

    54 Pages

  61. CQM

    15 Pages

  62. NCA1

    63 Pages

  63. CM2

    152 Pages

  64. NCM

    91 Pages

  65. NCG

    96 Pages

  66. NCRA1

    5 Pages

  67. CS2

    32 Pages

  68. T/TIA

    1 Pages

  69. KR

    7 Pages

  70. KF

    16 Pages

  71. KQ

    80 Pages

  72. AFF

    80 Pages

  73. AMG

    80 Pages

  74. IDF

    16 Pages

  75. HAA

    3 Pages

  76. ZFA

    14 Pages

  77. ZA

    13 Pages

  78. MHF

    32 Pages

  79. CRB

    44 Pages

  80. D

    117 Pages

  81. RB

    23 Pages

  82. CEP

    44 Pages

  83. rsq

    30 Pages

  84. CLK

    51 Pages

  85. MK

    20 Pages

  86. CLJ

    65 Pages

  87. MGJ

    7 Pages

  88. ZSE30A

    17 Pages

  89. IDFB*E

    89 Pages

  90. ISE10

    16 Pages

  91. ITV1000/2000

    50 Pages

  92. AW

    27 Pages

  93. NVFM200

    12 Pages

  94. NVM100

    32 Pages

  95. LLA*A

    36 Pages

  96. VX3*

    41 Pages

  97. SY3000

    158 Pages

  98. CH(D)2

    175 Pages

  99. LEHZ

    82 Pages

  100. M(D)SUB

    31 Pages

  101. CXSJ

    58 Pages

  102. CY3B

    39 Pages

  103. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages