Catalog excerpts
Compact Hydraulic Cylinder
Open the catalog to page 1Compact Hydraulic Cylinder Series CHdQB With Auto Switch With auto switchT" (built-in magnet) Mounting: Basic style Bore size Refer to the standard stroke Action: Double acting For details, referto page 165. Number of auto switches Auto switch type Without auto switch * Select applicable auto switch models from the table below. standard for male thread Built-in Magnet Cylinder Model If a built-in magnet cylinder without auto switch is required, there is no need to enter the symbol for the auto switch. Applicable Auto Switches: Refer to pages 347 to 406 for further details on each auto...
Open the catalog to page 2Compact Hydraulic Cylinder Series CHUQB |%der°| Made to order specifications ^5M^ (For details, refer to page 170) Note) Referto page 134 for definitions of terms related to pressure. Hydraulic Fluid Compatibility Standard Strokes Note) Consult with SMC regarding the manufacture of strokes other than the above.
Open the catalog to page 3Series CHUQB Theoretical Output Theoretical output (N) = Pressure (MPa) x Piston area (mm2) ASpecific Product Precautions Be sure to read before handling. Refer to front matters 30 and 31 for Safety Instructions, and pages 134 to 142 for precautions for hydraulic cylinder and auto switch. 1. Use hexagon socket head cap screws (JISB1176, strength class 10.9 or high- 2. Since a lateral load (eccentric load) cannot be applied to the piston rod, build the mounting jig in such a way that a lateral load will not be applied to 3. Make sure that the interlocking length of the rod end thread (male...
Open the catalog to page 4Compact Hydraulic Cylinder Series CHUQB Mounting Bolts for CHDQB Mounting: Through hole type mounting bolts are available. How to order: Add "Bolt" in front of the bolts to be used. Mounting bolt diagram Mounting bolt
Open the catalog to page 5Series CHUQB Parts List Replacement Parts: Seal Kit * Seal kit consists of Items ®, ®, © and © and can be ordered by using the seal kit number for each bore size. * Special tool required for disassembly. Contact SMC for recommended tool
Open the catalog to page 6Compact Hydraulic Cylinder Series CHUQB radius of lead wire 10 (port size) H with effective thread Note) The auto switches above are shown for a D-M9D(W) solid state auto switch.
Open the catalog to page 7Series CHDQB Made to Order Specifications: Please consult with SMC for detailed specifications, delivery and prices. Intermediate Strokes (Using Exclusive Body) Bore size Intermediate stroke (Using exclusive body) When using an intermediate stroke other than the compact hydraulic cylinder (Series CHDQB) standard strokes, it is possible to shorten the overall length and reduce the mounting space by using an exclu- sive body that does not have spacers installed. * Dimensions other than the above are the same as the standard double acting single rod type. Note) Applicable strokes are available...
Open the catalog to page 8Compact Hydraulic Cylinder Series CHUQWB With Auto Switch With auto switch"!" (built-in magnet) Model: Double acting/Double rod Mounting: Basic style Bore size auto switches Auto switch type Without auto switch * Select applicable auto switchD models from the table below. Female threadC Male thread Refer to the standard stroked Action: Double acting Applicable Auto Switches: Refer to pages 347 to 406 for further details on each auto switch. standard for male thread Built-in Magnet Cylinder Model If a built-in magnet cylinder without auto switch is required, there is no need to enter the...
Open the catalog to page 9Series CHUQWB Note) Referto page 134 for definitions of terms related to pressure. Hydraulic Fluid Compatibility Standard Strokes Note) Consult with SMC regarding the manufacture of strokes other than the above.
Open the catalog to page 10Compact Hydraulic Cylinder Series CHUQWB Theoretical Output Theoretical output (N) = Pressure (MPa) x Piston area (mm2) ASpecific Product Precautions Be sure to read before handling. Refer to front matters 30 and 31 for Safety Instructions, and pages 134 to 142 for precautions for hydraulic cylinder and auto switch. 1. Use hexagon socket head cap screws (JISB1176, strength class 10.9 or higher) for cylinder mount- 2. Since a lateral load (eccentric load) cannot be applied to the pis- ton rod, build your mounting jig in such a way that a lateral load will 3. Make sure that the interlocking...
Open the catalog to page 11Series CHUQWB Mounting Bolts for CHDQWB Mounting: Through hole type mounting bolts are available. How to order: Add "Bolt" in front of the bolts to be used. Mounting Bolts Mounting bolt diagram
Open the catalog to page 12Compact Hydraulic Cylinder Series CHUQWB Parts List Replacement Parts: Seal Kit * Seal kit consists of Items ®, ®, © and © and can be ordered by using the seal kit number for each bore size. * Special tool required for disassembly. Contact SMC for recommended tool
Open the catalog to page 13Series CHUQWB radius of lead wire 10 Note) The auto switches above are shown for a D-M9D(W) solid state auto switch.
Open the catalog to page 14Seríes CHUQB/CHUQWB Auto Switch Specifications Refer to pages 347 to 406 for detailed specifications. Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection Auto Switch Proper Mounting Positions Note) Adjust the auto switch after confirming the operating conditions in the actual setting. Auto Switch Mounting Heights
Open the catalog to page 15Series CHUQB/CHUQWB Minimum Auto Switch Mounting Stroke Operating Range * Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately ±30% dispersion.) There may be the case it will vary substantially depending on an ambient environment. I Besides the models listed in "How to Order," the following auto switches are applicable. ¡ I Refer to pages 347 to 406 for detailed auto switch specifications. ■ 1 * Solid state switches are also available with pre-wired connector. Refer to pages 389 and 390 for details. I I * Normally closed (N.C. = b contact),...
Open the catalog to page 16Compact Hydraulic Cylinder Series CHUQB/CHUQWB Auto Switch Mounting Brackets: Part Nos. Auto switch mounting surface Auto switch Auto switch mounting surface Auto switch mounting rail surface only Port side Auto switch mounting surface Port side Port side Auto switch mounting surface Two types of auto switch mounting bracket Two types of auto switch mounting Auto switch Auto switch mounting Note 1) To mount a compact auto switch on either of the three sides (A, B, and C above) other than the port side, mounting brackets are required separately other than the auto switch mounting brackets in...
Open the catalog to page 17All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog